Soleus Air KFHIP-09-OD installation manual Care and Maintenance

Page 20
Care and Maintenance

Care and Maintenance

Care and Maintenance

CAUTION:

Turn power off and pull out the power cord before cleaning air conditioner.

◆Care and Maintenance Never sprinkle water on the indoor unit and the outdoor unit for cleaning because it can cause an electric shock.

Manual background Volatile Liquid (e.g. thinner or gasoline) will damage the air conditioner. (So wipe the units with a dry soft cloth, or a cloth slightly moistened with water or cleanser.)

Clean the front panel (Don’t remove the front panel when cleaning)

When the indoor unit front panel is dirty, please use the cloth which is soaked in the warm water under 104°F, then dry it and wipe the dirty places.

NOTE:

There are microcomputer components and circuit board on the displayer of the indoor unit front panel, never let it dip in the water.

Cleaning the Air Filters (Recommended once every three months)

The air filters should be cleaned more frequently in dusty conditions.

1. Take down the air filter

Open the surface panel, hold the tab of air filter and raise it slightly, and then take it out along the direction of arrows (See the right figure).

2. Cleaning

To clear the dust adhering to the filters, you can either use a vacuum cleaner, or wash them with water and dry it in the shade (See the right figure).

Note: Never use water above 113°F to wash the filters, or it could cause deformation or discoloration. Never parch it by fire, or it could cause a fire or deformation.

- 18 -

Image 20
Contents Indoor Unit Outdoor Unit OPERATING AND INSTALLATION MANUALWall Mounted Mini Split Heat Pump Air Conditioner Model KFIHP-09-ID / KFHIP-09-ODTABLE OF CONTENTS Structure and Operation Name of Each PartThe Instructions before Use The Instructions before Use Set the room temperature appropriatelySpecification and Technical Data ModelKFIHP-09-ID KFHHP-12-IDRemote Control Operation Function-RemotecontrolRemote Control Operation Continued How to Insert Batteries Operation The general procedureProcedure for SLEEP mode Installation Installation LocationIndoor Unit Outdoor UnitElectric Wiring Grounding Requirement112.6 inch 212.6 inch Installation Dimension DiagramImportant Notes Installation Install the rear panelInstall the piping hole Install the drainage hoseInstallation 6.Recover the surface panelInstall the Indoor Unit Install the Outdoor Unit Install the connection pipeElectric wiring connection Tightening Torque TableAir Purging and Leakage Test Install the Outdoor UnitTest Operation and Check after Installation Check after InstallationTest Operation 1.Before Test OperationCare and Maintenance Care and MaintenanceCare and Maintenance Continued Trouble ShootingProblem Trouble ShootingTrouble Shooting ProblemTrouble Shooting Because the air of the room is cooled down rapidlyTrouble Shooting Unusual noise can be heard during operationElectrical Schematic Diagram Indoor Unit Please Insert Diagram in hereElectrical Schematic Diagram Electrical Schematic Diagram Outdoor Unit Please Insert Diagram in hereWarranty