Soleus Air KFHIP-09-OD Specification and Technical Data, Model, KFIHP-09-ID, KFHHP-12-ID

Page 6
◆Specification and Technical Data

Specification and Technical Data

 

Model

 

 

KFIHP-09-ID

 

KFHHP-12-ID

 

 

 

KFIHP-09-OD

 

KFHHP-12-OD

 

 

 

 

 

 

 

 

Function

 

 

 

 

 

Cool / Heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Accessory

 

 

 

 

 

Air Cleaner

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling capacity (Btu/h)

 

 

9000

 

12000

 

 

 

 

 

 

 

 

 

 

 

Heating capacity (Btu/h)

 

 

9500

 

13000

 

 

 

 

 

 

 

 

 

 

 

Power Supply (V)

 

 

115V~

 

208~230

 

 

 

 

 

 

 

 

 

 

 

 

Frequency (Hz)

 

 

 

 

 

60

 

 

 

 

 

 

 

 

 

 

 

 

Cooling/Heating rated current(A)

 

12/13.6

 

9/10

 

 

 

 

 

 

 

 

 

 

Cooling/Heating rated power(W)

 

1250/1450

 

1700/1750

 

 

 

 

 

 

 

 

 

 

Cooling/Heating power input(W)

 

730/840

 

1100/1200

 

 

 

 

 

 

 

 

 

 

Recycling air Volumem3/h

 

 

550

 

 

Refrigerant and weight(lbs)

 

 

R410A

2.6 lbs

 

R410A 2.8 lbs

 

 

 

 

 

 

 

 

 

 

 

 

Water proof level

 

 

 

 

 

IP24

 

 

 

 

 

 

 

 

 

 

 

 

Noise(Indoor/Outdoor)dB(A)

 

 

 

43/55

 

 

 

 

 

 

 

 

 

 

 

 

 

Climate type

 

 

 

 

 

T1

 

 

 

 

 

 

 

 

 

 

 

Anti-electric shock protection

 

 

I

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight Indoor/Outdoor)(lbs)

 

 

24.3/99.2

 

24.3/99.2

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions

 

Indoor unit

 

 

30.31”×7.48”×9.84”

 

32.68”×8.86”×11.22”

(W x D x H)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor unit

 

33.39”×12.6”×21.26”

 

33.39”×12.6”×21.26”

Connection Pipe:

 

 

 

 

 

 

 

 

Length (ft)

 

 

 

 

 

19.68

 

 

 

 

Gas additional charge(oz/ft)

 

 

 

0.16

 

 

 

 

Outer Diameter

 

 

Liquid Pipe (mm)

Φ6(1/4”)

 

 

 

 

 

Gas Pipe (mm)

 

Φ12(1/2”)

 

 

 

 

 

 

 

 

 

 

 

Max Distance

 

 

Height (ft)

 

16.4

 

 

 

 

 

 

Length (ft)

 

49.21

 

 

 

 

 

 

 

 

 

 

 

 

1.

All above are tested and certified to ETL specification.

 

 

2.

All above could be changed without notice; the latest specifications are on the nameplate of your air conditioner.

3.

When the unit is restarted after it stopping, it can automatically resume the last running mode, and the outdoor unit

 

starts later.

 

 

 

 

Working temperature range:

 

 

 

 

 

Indoor side DB/WB(°F)

Outdoor side DB/WB(°F)

 

 

 

 

 

 

 

 

 

Maximum cooling

89.6 / 73.4

109.4 / 78.8

 

 

 

Minimum cooling

69.8 / 59

69.8 / -

 

 

 

Maximum heating

80.6 / -

75.2 / 64.4

 

 

 

Minimum heating

68 / -

23 / 21.2

 

- 4 -

Image 6
Contents Wall Mounted Mini Split Heat Pump Air Conditioner Indoor Unit Outdoor UnitOPERATING AND INSTALLATION MANUAL Model KFIHP-09-ID / KFHIP-09-ODTABLE OF CONTENTS Structure and Operation Name of Each PartThe Instructions before Use The Instructions before Use Set the room temperature appropriatelyKFIHP-09-ID Specification and Technical DataModel KFHHP-12-IDRemote Control Operation Function-RemotecontrolRemote Control Operation Continued How to Insert Batteries The general procedure Procedure for SLEEP modeOperation Indoor Unit InstallationInstallation Location Outdoor UnitElectric Wiring Grounding RequirementInstallation Dimension Diagram Important Notes112.6 inch 212.6 inch Install the piping hole InstallationInstall the rear panel Install the drainage hoseInstallation 6.Recover the surface panelInstall the Indoor Unit Electric wiring connection Install the Outdoor UnitInstall the connection pipe Tightening Torque TableAir Purging and Leakage Test Install the Outdoor UnitTest Operation Test Operation and Check after InstallationCheck after Installation 1.Before Test OperationCare and Maintenance Care and MaintenanceProblem Care and Maintenance ContinuedTrouble Shooting Trouble ShootingTrouble Shooting Trouble ShootingProblem Because the air of the room is cooled down rapidlyTrouble Shooting Unusual noise can be heard during operationPlease Insert Diagram in here Electrical Schematic DiagramElectrical Schematic Diagram Indoor Unit Electrical Schematic Diagram Outdoor Unit Please Insert Diagram in hereWarranty