HP Z800 manual Configuring the Lucid ADA 88192 Converter

Page 29

 

 

 

 

 

 

 

 

AES/EBU

 

 

 

 

 

AJA

 

 

 

 

 

 

 

 

 

 

 

Audio

In

In

In

 

In

 

Video MonitorOut

 

RS-422

 

 

 

 

 

 

 

 

 

 

Y/G/CVBS

Pb/B/Y

Pr/R/C

 

 

 

 

 

 

 

 

 

Out

Out

Out

 

Out

 

 

 

 

 

Ch. 1/2 In

Ch. 3/4 In

Ch. 5/6 In

Ch. 7/8 In

Ch. 1/2 Out

Ch. 3/4 Out

Ch. 5/6 Out

Ch. 7/8 Out

Ch. 1/2

Ch. 3/4

Ch. 5/6

Ch. 7/8

SDI 1/A

SDI 2/B

Ref Loop

 

 

Ch.1(L)

Ch.2(R)

AJA BOB (Front)

Digital outputs

to serial port 1 on Linux workstation

88192 A/D D/A CONVERTER

 

AES/EBU Digital

Inputs

Analog Inputs

 

Input from analog source

RS-232

WORD CLOCK 7-8

5-6

3-4

1-2

8

7

6

5

4

3

2

1

 

INPUT

 

AES/EBU Digital Outputs

 

 

 

Analog Outputs

 

 

 

ADAT OUT 1-8 ADAT IN 1-8

OUTPUT

7-8

5-6

3-4

1-2

8

7

6

5

4

3

2

1

 

 

 

 

 

 

 

 

 

 

 

 

Lucid ADA 88192

Converter Digital

outputs

Output to analog destination

Alternative setup

 

 

converted from

IN

IN IN IN

 

 

analog source

OUT

OUT OUT OUT

 

VTR

Required for remote control of converter

Configuring the Lucid ADA 88192 Converter

You must manually configure the Lucid converter for either remote or local control. This section describes how to use the controls on the front of the converter to adjust settings, and lists the proper settings for remote control and for local control.

Understanding Remote vs. Local Control of the Lucid Converter

You can control the converter either remotely or locally. Remote control of the converter means that you adjust converter settings through the audio preferences of the application. If you want to control the converter

Configuring the Lucid ADA 88192 Converter 25

Image 29
Contents HP Z800 Workstation Hardware Setup Guide Trademarks Contents Setting Up Video Hardware Iv ContentsRelated Documentation IntroductionAbout This Guide Contacting Customer Support Notation ConventionsIntroduction Convention ExampleGeneral Workflow Getting StartedGetting Started Workstation Control Surface Lustre Master Workstation Typical Configuration Overview for Autodesk LustrePower and Air Conditioning Requirements Hardware Configuration GuidelinesHardware Configuration Guidelines Memory RequirementsComponent Quantity Startup Amps Cont. Amps Watts Rack Mount Requirements120V 240V Unit Conversion ExampleGrounding Audio Hardware Components Avoiding Damage from Static ElectricityReceiving Your Shipment Avoiding Damage from Static ElectricityPage Workflow for Connecting Peripherals Connecting PeripheralsConnecting Peripherals Connecting the Graphics MonitorConnections Overview To connect the monitorConnecting the Keyboard, Mouse, and Tablet Connecting the Keyboard, Mouse, and TabletConnecting the Graphics Monitor Calibration Device Network Connections To enable the Eye-One calibration utility driverVisual Effects and Finishing Workstation Connect the built-in GigE port as followsLustre Workstation Connecting the Autodesk Control SurfaceLustre Workstation Connect the GigE adapter as followsTo connect the Autodesk Control Surface Connecting the Slave Renderer to a Lustre WorkstationHP Z800 Workstation To connect the Slave Renderer Connecting the Slave Renderer to a Lustre WorkstationPage Included Components Setting UpVideo Hardware4Video Hardware Components Setting Up Video Hardware Wiring Your Video ComponentsSetting Up VTR Emulation Setting Up VTR EmulationTo configure hardware for VTR emulation Audio Wiring Workflow SettingUpAudioHardware5To wire the audio subsystem About AudioAudio Hardware Components Audio WiringSetting Up Audio Hardware Configuring the Lucid ADA 88192 Converter Configuring the Lucid ADA 88192 ConverterTo navigate menus and adjust settings Adjusting Lucid ADA 88192 Converter SettingsTo reset all settings to their factory defaults Do thisLucid ADA 88192 Converter Settings for Local Control Lucid ADA 88192 Converter Settings for Remote ControlLucid ADA 88192 Converter Settings for Remote Control Menu Menu Item CommentAJA Keyword SettingOverview Connecting StorageConnecting Media Storage Storage Configuration Loops Expected Peformance Connecting the HP Z800 Atto Fibre Channel AdapterConnecting Storage Connecting the HP Z800 Atto Fibre Channel Adapter XR 6500 Wiring Diagrams Connecting Storage EnclosuresSingle XR 6500 RAID enclosure, 4 loops Connecting Storage EnclosuresSingle XR 6412 RAID enclosure, 2 loops XR 6412 Wiring DiagramsSingle XR 6412 RAID enclosure, 4 loops XR 5402 and XR 5412 Wiring Diagrams Connecting Archiving Storage Connecting Archiving StorageFilesystem Devices Scsi Tape Drive DevicesConnecting Storage Scsi Tape Drive Devices Page Bios Menu Submenu Value Configuring Workstation BiosHP Z800 Bios Settings To restore default factory Bios settings Restoring Bios to Default Factory SettingsConfiguring the Workstation Bios To update the Bios on your workstation Updating your System BiosUpdating your System Bios Workstation reboots Standard VTR Control Cable Pinouts VTR Control Cable PinoutsAppendix a VTR Control Cable Pinouts VTR Emulation RS-422 Control CablesLinuxAJA Linux Master to Linux Emulator Linux Master to Linux EmulatorLinuxAJA Master LinuxAJA Emulator VTR-Emulation Control Cable Third-Party Master to Linux EmulatorIndex IndexRAID