Sterling TF-150 installation instructions Tubular GAS Fired Direct Spark Propeller Unit Heaters

Page 1

INSTALLATION INSTRUCTIONS AND PARTS LIST

(S) DSTBIM-3

J30-06935

TUBULAR GAS FIRED DIRECT SPARK PROPELLER UNIT HEATERS

ATTENTION: READ THIS MANUAL AND ALL LABELS ATTACHED TO THE UNIT CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THESE UNITS! CHECK UNIT DATA PLATE FOR TYPE OF GAS AND ELECTRICAL SPECIFICATIONS AND MAKE CERTAIN THAT THESE AGREE WITH THOSE AT THE POINT OF INSTALLATION. RECORD THE UNIT MODEL AND SERIAL No.(s) IN THE SPACE PROVIDED. RETAIN FOR FUTURE REFERENCE.

Model No.

 

Serial No.

FOR YOUR SAFETY

The use and storage of gasoline or other flammable vapors and liquids in open containers in the vicinity of this appliance is hazardous.

FOR YOUR SAFETY

If you smell gas:

1.Open windows.

2.Don't touch electrical switches.

3.Extinguish any open flame.

4.Immediately contact your gas supplier.

Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Read the installation, operating, and maintenance instruction thoroughly before installing or servicing this equipment.

APPROVED FOR USE IN CALIFORNIA

Install, operate, and maintain unit in accordance with the manufacturer's instructions to avoid exposure to fuel substances, or substances from incomplete combustion, which can cause death or serious illness. The state of California has determined that these substances may cause cancer, birth defects, or other reproductive harm.

INSTALLER'S RESPONSIBILITY

Installer Please Note: This equipment has been test fired and inspected. It has been shipped free from defects from our factory. However, shipment and installation problems such as loose wires, leaks, or loose fasteners may occur. It is the installer's responsibility to inspect and correct any problem that may be found.

RECEIVING INSTRUCTIONS

Inspect shipment immediately when received to determine if any damage has occurred to the unit during shipment. After the unit has been uncrated, check for any visible damage to the unit. If any damage is found, the consignee should sign the bill of lading indicating such damage and immediately file claim for damage with the transportation company.

03/07

HVAC PRODUCTS

260 NORTH ELM ST., WESTFIELD, MA 01085 TEL: (413) 564-5540 FAX: (413) 562-5311

www.sterlinghvac.com

MODELS: TF-100, 125, 150, 175, 200, 250, 300, 350, 400 GF-150, 250, 400

Please utilize this toll free number to contact your local representative 800-490-2290.

Image 1
Contents Receiving Instructions Tubular GAS Fired Direct Spark Propeller Unit HeatersDescription Table of ContentsGeneral Safety Information Dimensional Drawing Tubular Propeller Unit Heater Installation Installation Pipe Sizing GAS PipingGas Pipe Size Gas Piping Requirements Pipe InstallationThermostat Wiring and Location Low-voltage T Thermostat Wiring Single Stage Two StageElectrical Connections Electrical Connections Tubular Unit Sizes with Optional 2 Stage Ignition Vertically Vented Unit Heaters Category VentingVenting Categories Structure Termination Locations Horizontally Vented Unit Heaters CategoryVenting Venting Venting Explanation of Controls See Figure OperationShut Down GAS Input Rate Primary AIR Shutter AdjustmentMain Burner Orifice Schedule Natural GAS Propane LP GAS Tubular Unit Heater High Altitude DerationSymptoms Possible Causes Corrective Action Tubular Propeller Troubleshooting GuideRealign power ventor wheel Check for continuous 115v on terminal LED Status Indicates CHECK/REPAIR Periodic Service MaintenanceNever over oil the motor or premature failure may occur Power Vented Tubular Propeller Unit Heaters Limited WarrantyPropeller Parts Heat Exchanger AssemblyTurbulator/High Limit Location Power Venter AssemblyWith power and gas on With power and gas offPRE-INSPECTION Information General