Sterling TF-350, TF-400, TF-150, TF-300, TF-200 Dimensional Drawing Tubular Propeller Unit Heater

Page 4

Table 1 - Performance and Dimensional Data - Tubular Propeller Unit Heater

Unit Size

100

125

150

175

200

250

300

350

400

PERFORMANCE DATA†

 

 

 

 

 

 

 

 

 

Input - BTU/Hr.

100,000

125,000

150,000

175,000

200,000

250,000

300,000

350,000

400,000

(kW)

(29.3)

(36.6)

(43.9)

(51.2)

(58.6)

(73.2)

(87.8)

(102.5)

(117.1)

Output - BTU/Hr.

81,000

101,250

121,500

141,750

162,000

202,500

243,000

283,500

324,000

(kW)

(23.7)

(29.6)

(35.6)

(41.5)

(47.5)

(59.3)

(71.2)

(83.0)

(95.0)

Thermal Efficiency (%)

81

81

81

81

81

81

81

81

81

Free Air Delivery - CFM

1,600

2,200

2,400

2,850

3,200

3,450

5,000

5,600

5,800

(cu. m/s)

(0.756)

(1.039)

(1.133)

(1.346)

(1.511)

(1.629)

(2.361)

(2.644)

(2.738)

Air Temperature Rise - Deg. F

47

42

47

46

47

54

45

47

51

(Deg. C)

(26)

(23)

(26)

(26)

(26)

(30)

(24)

(26)

(28)

Full Load Amps at 120V

5.3

5.8

5.8

8.0

8.0

8.0

11.3

13.5

13.5

MOTOR DATA: Motor HP (Qty.)

1/10

1/4

1/4

1/3

1/3

1/3

(2) 1/4

(2) 1/3

(2) 1/3

Motor kW

(0.080)

(0.19)

(0.19)

(0.25)

(0.25)

(0.25)

(0.19)

(0.25)

(0.25)

Motor Type

SP

PSC

PSC

PSC

PSC

PSC

PSC

PSC

PSC

R.P.M.

1,050

1,140

1,140

1,140

1,140

1,140

1,140

1,140

1,140

Amps @ 115V

4.2

4.7

4.7

5.8

5.8

5.8

9.4

11.6

11.6

DIMENSIONAL DATA - inches (mm)

 

 

 

 

 

 

 

 

“A” Overall Height to Top of Flue

33-3/4

33-3/4

33-3/4

33-3/4

33-3/4

33-3/4

34

34

34

 

(857)

(857)

(857)

(857)

(857)

(857)

(864)

(864)

(864)

“B” Jacket Width of Unit

20-3/4

20-3/4

20-3/4

32-3/4

32-3/4

32-3/4

50-3/4

50-3/4

50-3/4

 

(527)

(527)

(527)

(831)

(831)

(831)

(1289)

(1289)

(1289)

“C” Width to CL Flue

13-3/8

13-3/8

13-3/8

19-3/8

19-3/8

19-3/8

28-3/8

28-3/8

28-3/8

 

(340)

(340)

(340)

(492)

(492)

(492)

(721)

(721)

(721)

“D” Depth to Rear of Housing

11

11

11

11

11

11

12-1/4

12-1/4

12-1/4

 

(279)

(279)

(279)

(279)

(279)

(279)

(311)

(311)

(311)

“E” Hanging Distance Width

18-5/8

18-5/8

18-5/8

30-5/8

30-5/8

30-5/8

48-5/8

48-5/8

48-5/8

 

(473)

(473)

(473)

(778)

(778)

(778)

(1235)

(1235)

(1235)

“F” Discharge Opening Width

18-3/4

18-3/4

18-3/4

30-3/4

30-3/4

30-3/4

48-3/4

48-3/4

48-3/4

 

(476)

(476)

(476)

(781)

(781)

(781)

(1238)

(1238)

(1238)

“G” Depth to CL Flue

4-3/4

4-3/4

4-3/4

4-3/4

4-3/4

4-3/4

5-1/8

5-1/8

5-1/8

 

(121)

(121)

(121)

(121)

(121)

(121)

(130)

(130)

(130)

“H” Discharge Opening Height

24-1/2

24-1/2

24-1/2

24-1/2

24-1/2

24-1/2

24-1/2

24-1/2

24-1/2

 

(622)

(622)

(622)

(622)

(622)

(622)

(622)

(622)

(622)

“L” Overall Unit Width

25-1/4

25-1/4

25-1/4

37-1/4

37-1/4

37-1/4

55-1/4

55-1/4

55-1/4

 

(641)

(641)

(641)

(946)

(946)

(946)

(1403)

(1403)

(1403)

*Flue Size Diameter - in.

5

5

5

5

5

5

6

6

6

(Dia.-mm)

(127)

(127)

(127)

(127)

(127)

(127)

(152)

(152)

(152)

Fan Diameter - in. (Qty.)

16

16

16

18

18

18

(2) 16

(2) 18

(2) 18

Gas Inlet-Natural Gas (in.)

1/2

1/2

1/2

1/2

1/2

3/4

3/4

3/4

3/4

Gas Inlet- LP Gas (in.)

1/2

1/2

1/2

1/2

1/2

1/2 OR 3/4

1/2 OR 3/4

1/2 OR 3/4

1/2 OR 3/4

Approximate Unit Weight - lbs.

133

145

155

191

201

211

307

321

335

(kg)

(60)

(66)

(70)

(87)

(91)

(96)

(139)

(145)

(152)

Approximate Ship Weight - lbs.

173

185

195

241

251

261

367

381

395

(kg)

(78)

(84)

(88)

(109)

(114)

(118)

(166)

(173)

(179)

* For all installations, the flue collar is included with the unit and should be field installed per the instructions included with the unit.

Ratings shown are for unit installations at elevations between 0 and 2,000 ft (0 to 610m). For unit installations in U.S.A. above 2,000 ft. (610m), the unit input must be derated 4% for each 1,000 ft. (305m) above sea level; refer to local codes, or in absence of local codes, refer to the latest edition of the National Fuel Gas Code, ANSI Standard Z223.1 (N.F.P.A. No. 54).

For installations in Canada, any reference to deration at altitudes in excess of 2,000 ft. (610m) are to be ignored. At altitudes of 2,000 ft. to 4,500 ft. (610 to 1372m), the unit must be derated to 90% of the normal altitude rating, and be so marked in accordance with the ETL certification.

1-3/8"

E

(35)

D

32-1/2"

L

(Hanging)

(Hanging)

 

 

 

 

 

 

 

 

 

 

Flue *

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical Control Panel

D4617

 

 

Rear View

D4617

 

11-5/8" (826)

G (295) (Hanging)

Gas Valve

Side View

B

F

(Discharge Opening)

Front View

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

 

 

 

 

 

 

(Discharge

 

 

 

 

A

 

Opening)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

33"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1" (25)

DIMENSIONS .XXX STANDARD UNITS

DIMENSIONS IN PARENTHESIS (XXX) MILLIMETERS

Figure 2 - Dimensional Drawing – Tubular Propeller Unit Heater

4

Image 4
Contents Tubular GAS Fired Direct Spark Propeller Unit Heaters Receiving InstructionsTable of Contents DescriptionGeneral Safety Information Dimensional Drawing Tubular Propeller Unit Heater Installation Installation Pipe Sizing GAS PipingGas Pipe Size Pipe Installation Gas Piping RequirementsThermostat Wiring and Location Low-voltage T Thermostat Wiring Single Stage Two StageElectrical Connections Electrical Connections Tubular Unit Sizes with Optional 2 Stage Ignition Vertically Vented Unit Heaters Category VentingVenting Categories Horizontally Vented Unit Heaters Category Structure Termination LocationsVenting Venting Venting Explanation of Controls See Figure OperationShut Down GAS Input Rate Primary AIR Shutter AdjustmentMain Burner Orifice Schedule Tubular Unit Heater High Altitude Deration Natural GAS Propane LP GASTubular Propeller Troubleshooting Guide Symptoms Possible Causes Corrective ActionRealign power ventor wheel Check for continuous 115v on terminal LED Status Indicates CHECK/REPAIR Periodic Service MaintenanceNever over oil the motor or premature failure may occur Limited Warranty Power Vented Tubular Propeller Unit HeatersHeat Exchanger Assembly Propeller PartsPower Venter Assembly Turbulator/High Limit LocationWith power and gas off With power and gas onPRE-INSPECTION Information General