9. Technical Data

9.1. STT 110

amount of dehumidified air:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . max. 110 m3/h (3,8846.1 cf/h)

operating voltage:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400 V/3 AC/50 Hz special voltages can be supplied on request

connected load: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2 kW

calorific output (drying)*: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . max. 9.0 kW *depending on the equipment with hopper heaters

calorific output (regenerating):. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.4 kW

driving power (drying, regenerating): . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.75 kW

drying temperature: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . max. +180 °C(356°F)

width: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 900 mm (35.5 in.)

depth:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 666 mm (26.2 in.)

height: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1320 mm (52.0 in.)

weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . approx. 180 kg (396.83 lbs.)

noise: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . approx. 66 dB (A)

options: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . timer clock

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . dew point display

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . return air cooler

Return Air Cooler

water flow rate in the water mains network*:. . . . . . . . . . . . . . . approx. 0.35 m3/h (12.46cf/h)

(*water temperature: +6 °C) (42.8°F)

Ø pipe connection:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2” (0.5 in.)

SM2-605

Technical Data 9-1

Image 48
Contents Operating Instructions Dehumidified air dryer STT Sterling Material ProcessingParts and Service Department STT 110 / STT Sterling Material Processing Edition 04/02STT 110 / STT Table of contents Transport, Assembly and Storage Assembly instructionsTechnical Data Spare parts list Electrical manualGeneral Information General InformationSTT 110 / STT STT 110 / STT CTT 110 / CTT Explanations and information Legal basisFields of applications Safety instructions Safety instructionsSTT 110 / STT For your safety GeneralAssembly OperationMaintenance STT 110 / STT For the safety of the devices Start up Start upSwitching on the Dryer For operation with timer clock optionalFor operation without timer clock STT 110 / STT Initial OperationExit Switching the Dryer on STT 110 / STT Continuous OperationSTT 110 / STT Setting the Drying Temperature Exit Optimizing the thermo regulatorSTT 110 / STT Switching the Dryer off Error and error correction Error and error correctionFollowing errors can lead to an alarm Blower Regeneration heaterHopper heater Maintenance MaintenanceSTT 110 / STT STT 110 / STT Maintenance schedule STT 110 / STT Cleaning or Replacing the Air Filter STT 110 / STT Cleaning or Replacing the Return Air Filter STT 110 / STTSTT 110 / STT Disposing of Drying Agents STT 110 / STT Cleaning the Drying Hopper STT 110 / STT ST 60 ST Functional description Functional descriptionSTT 110 / STT General Information STT 110 / STT STT 110 / STT STT 110 / STT Drying Hopper Optional 180 STT 110 / STT Hopper HeaterReturn Air Cooler Optional Transport, Assembly and Storage Transport, Assembly and StorageSTT 110 / STT Tansport and Packing STT 110 / STT Assembly StorageAssembly instructions Assembly instructionsGrounding the equipment against electrostatic charging STT 110 / STT Electrical Connection STT 110 / STT Connection of Return Air Cooler Optional Technical Data Technical DataSTT Return Air CoolerSTT 110 / STT STT 110 / STT Dimension Sheet Spare parts list Spare parts listSTT 110 / STT Pos ID-number DescriptionReturn air cooler optional Operating unit Pos ID-number Description Control unit Electrical manual Electrical manualAccessories AccessoriesBasic setting thermo regulator CodeParameter Parameter set