Sterling STT 500 manual Dehumidified Air Dryer Assembly, Storage

Page 66

Dehumidified Air Dryer

7.2. Assembly

»

Please ensure adequate carrying capacity of the lifting equipment.

Check the carrying capacity of the point of installation, particularly if installed on a platform.

The place selected for installation should be as free of vibrations as possible.

The main switch must be freely accessible.

Ground the equipment against electrostatic charging.

A special foundation is not required for installation.

The dryer must be installed on a level surface, and may not be exposed to excessive humidity. Maximum permissible ambient temperature of the control system is 45 °C (113°.F)

To facilitate servicing, install the dryer such that it is accessible from 3 sides. Make sure that the air filters can be changed without problems. The rear of the dryer can be placed against a wall.

To conserve energy, keep the distances between dryer, hopper and processing machine as short as possible.

The location of the control unit should be chosen so that a clear view of the separators is guaran- teed from the control unit. Thus any malfunctions which arise can be corrected more easily.

Fasten the transport cables to the eyelets of the control cabinets. During transport do not contact or push against other components with the control panels.

7.3. Storage

The control system may only be stored at temperatures from -25 to +55°C (-13 to +131 °F).

Between delivery and machine commissioning the equipment should be stored in a dry, dust-free and vibration-free room.

SM2-620

Transport, Assembly and Storage 7-4

Image 66
Contents Sterling Material Processing Parts and Service Department STT Sterling Material Processing Edition 04/02 Order confirmation numberSTT Table of Contents Transport, Assembly and Storage Electrical manual General Information Dehumidified Air DryerGeneral Information Dehumidified Air Dryer Dehumidified Air Dryer Explanations and information Legal basisFields of applications Safety instructions Safety instructionsDehumidified Air Dryer For your safety GeneralAssembly OperationMaintenance Dehumidified Air Dryer For the safety of the devices Start-up Start-upSTT Control system Key assignmentSTT Flow chart Indicator lamp messagesSTT Switching on the dryer Operation statusesPasswords STT Viewing the software-versionLogin LogoutEdit Turning the devices on/off Timer on/offSTT Basic parameters Dryer on/offSTT Used air Act STT Entering dryer valuesRegeneration Heater Act Dew point maxReturn air cooler Target Return air cooler ActSTT Entering hopper values Hopper entry X TargetHopper entry X Act Granules Target % = C FGranules Act. C Valve block moved in/moved out/error STT Observing processing statusSTT Setting date and time DateTime STT Viewing/changing language and contrast ContrastLanguage Run on time drying blower -- 300 sec STT Changing parametersSelect Parameters ParametersSTT Setting the timer XX on 0000 OFF 0000 XX = day Mo-SuExample STT Starting continuous operation Select Main menuSystem runtime STT Viewing system runtimeSelect System runtime XX hSTT Switching the dryer off Error and error correction Error and error correctionLED Alarm View Waiting messages NumberTotal messages DeleteOverflow Overflow warning On/OffSafety Switch Regeneration Blower Has Been Actuated Main Switch is OffSafety Temperature Limiter has been Activated Safety Switch Drying Blower Has Been ActuatedInsufficient Temperature Regeneration Heater Temperature Measurement Regeneration Heater DefectiveExcess Temperature Regeneration Heater Safety Switch Regeneration Heater Has Been ActuatedInsufficient Temperature Drying Heater Temperature Measurement Drying Heater DefectiveExcess Temperature Drying Heater Safety Switch Drying HeaterTemperature Measurement Granules Defective Hopper Excess Temperature Granules HopperValve Error Hopper Maintenance MaintenanceSTT STT Maintenance intervals STT Cleaning/renewing the air filters Return air filter Regeneration air filter Filter of the electrical cabinet STT Tensioning the V-belts Blower regeneration heater / Blower drying heater Servicing the accessories Disposing of the drying agentHigh-pressure blowers with frequency converter operation STT Changing the battery of the control system STT STT Resetting the control values Functional description Functional descriptionDew point dependent regeneration switch optional STT DryerSTT Drying hopper optional STT Return air cooler STT Hopper heaters optional Automatic motor flaps optionalConnection to a pneumatic conveying system optional Transport, Assembly and Storage Transport, Assembly and StorageDehumidified Air Dryer Transport and Packing With a fork lift truckWith a workshop crane Dehumidified Air Dryer Assembly StorageAssembly instructions Assembly instructionsConnection of the air coolers Dehumidified Air Dryer Electrical connection Basic Equipment Technical DataTechnical Data Optional EquipmentSM2-620 All dimensions are in mm.in. Subject to alteration Dimension sheet Spare parts list Spare parts listPos. ID-number Description STT 83986 Moisture sensor Return air coler optional Switching Cabinet and Operating UnitAccessories Flaps optionalElectrical manual Electrical manualAccessories AccessoriesAccessories Entering values on the OP 7 Entering Values Entering Numerical Values Entering Alphanumeric Values Step Procedure Entering Symbolic Values Accessories Flap control with Fuzzy-Logic Flap control with Fuzzy-Logic Control unit flap

STT 500 specifications

The Sterling STT 500 stands out as a versatile and powerful tool designed for professionals in various industries, such as construction, manufacturing, and automotive. This innovative machine integrates advanced technologies and a range of features to enhance performance and user experience.

One of the key attributes of the Sterling STT 500 is its robust engine. Powered by a high-efficiency motor, it delivers impressive torque and power output, allowing it to handle heavy-duty tasks with ease. This machine can operate under demanding conditions, making it suitable for both indoor and outdoor applications.

The STT 500 boasts a user-friendly interface that includes an intuitive control panel. This feature allows operators to easily manage the machine's settings and monitor its performance in real-time. The clear digital display provides essential information, including power levels, operating modes, and maintenance alerts, ensuring that users can perform their tasks effectively and efficiently.

In terms of safety, the Sterling STT 500 is equipped with multiple protective features. This includes emergency shut-off systems and overload protection, which safeguard both the machine and the operator during operation. Additionally, its ergonomic design minimizes physical strain on users, contributing to a safer working environment.

The STT 500 also highlights its advanced connectivity options. With built-in Bluetooth and Wi-Fi capabilities, users can sync the machine with their devices for seamless data transfer and remote monitoring. This feature enables businesses to track machine performance, schedule maintenance, and optimize operations.

Durability is another hallmark of the Sterling STT 500. Constructed with high-quality materials, it is engineered to withstand the rigors of daily use. Its rugged chassis and protective casing ensure longevity, making it a valuable investment for any company looking to enhance their productivity.

The machine’s versatility is further augmented by various accessories and attachments that can be utilized for different applications. Whether it’s drilling, cutting, or grinding, the STT 500 can be tailored to meet diverse operational needs, allowing users to maximize their workflow.

In conclusion, the Sterling STT 500 is an exemplary choice for those seeking a powerful, efficient, and durable tool for their professional tasks. With its advanced technology, user-centric design, and safety features, it continues to meet and exceed the expectations of users across multiple industries.