Sterling 350-2100 CFM installation manual General Responsibility, Operator Responsibility

Page 9

1-4 Responsibility

These machines are constructed for maximum operator safety when used under standard operating conditions and when recommended instructions are followed in the maintenance and operation of the machine.

All personnel engaged in the use of the machine should become familiar with its operation as described in this manual.

Proper operation of the machine promotes safety for the operator and all workers in its vicinity.

Each individual must take responsibility for observing the prescribed safety rules as outlined. All warning and danger signs must be observed and obeyed. All actual or potential danger areas must be reported to your immediate supervisor.

General Responsibility

No matter who you are, safety is important. Owners, operators and maintenance personnel must realize that every day, safety is a vital part of their jobs.

If your main concern is loss of productivity, remember that production is always affected in a negative way following an accident. The following are some of the ways that accidents can affect your production:

Loss of a skilled operator (temporarily or permanently)

Breakdown of shop morale

Costly damage to equipment

Downtime

An effective safety program is responsible and economically sound.

Organize a safety committee or group, and hold regular meetings. Promote this group from the management level. Through this group, the safety program can be continually reviewed, maintained, and improved. Keep minutes or a record of the meetings.

Hold daily equipment inspections in addition to regular maintenance checks. You will keep your equipment safe for production and exhibit your commitment to safety.

Please read and use this manual as a guide to equipment safety. This manual contains safety warnings throughout, specific to each function and point of operation.

Operator Responsibility

The operator’s responsibility does not end with efficient production. The operator usually has the most daily contact with the equipment and intimately knows its capabilities and limitations.

Plant and personnel safety is sometimes forgotten in the desire to meet incentive rates, or through a casual attitude toward machinery formed over a period of months or years. Your employer probably has established a set of safety rules in your workplace. Those rules, this manual, or any other safety information will not keep you from being injured while operating your equipment.

350-2100 cfm Dryers

Chapter 1: Safety

9 of 58

Image 9
Contents Large Dehumidifying Dryers SDA Series 350 2100 CFMWrite Down Your Serial Numbers Here For Future Reference Shipping Info Table of Contents Maintenance Safety How to Use This ManualSafety Symbols Used in this Manual Dryer Safety Tags Safety Tag InformationWear Safety Glasses and Work Gloves Responsibility General ResponsibilityOperator Responsibility Remember Maintenance ResponsibilityReporting a Safety Defect Optional Features Typical Features and ComponentsFunctional Description Models Covered in This ManualWhat is Desiccant? Closed Loop Drying SystemProcess/Regeneration Cycle Cfm Dryers Functional Description TOP View Left Side View Work Rules InstallationElectrical Connections Check For Proper Blower RotationDrying Hopper Air Trap Aftercooler Cooling Water ConnectionTypical Control Panel Control Panel Control Panel Indicator LightsProcess Blower Failure Alarm Valve Position Error Switches and MetersPLC Control Process Air Temperature ControllerProcess Air Temperature Controller Process Value Numeric LED Temperature Controller LED IndicatorsOptional Communications Protocols Temperature Controller Keys See in SectionStartup, Shutdown & Operation Pre-Startup ChecksStartup Setting the High and Low Temperature Alarms Setting the Process Air TemperatureTo Change the Process Air High Temperature Alarm Setting ShutdownTemperature Controller Internal Switches Temperature Controller Autotune ProcedureTemperature Controller Anti-Tamper Lockout Switch Enabling the Lockout FeatureSetting the Dewpoint Extend Shift Point Changing the Display from Fahrenheit to CentigradeTo Change the Dewpoint Shift Point LL Setpoint Low Regeneration Alarm Setpoint 130F Regeneration Monitoring System Signal ProcessorSetpoint Regeneration Blower Shutdown Temp 160F HH Setpoint Heater Cut Off Temp 300FSeven Day Timer Optional Auxiliary Process Safety System OptionalSetting the start up time Setting the Current Day of the Week, Hour and MinuteSetting the stop time Put the timer into Run modeSet the days of the week for automatic operation Maintenance Filter Cleaning/ReplacementServicing the Process Air Filters Models Servicing the Process Air Filters Models 850 through Filter Cleaning/ReplacementDirty Filter Alarm Calibration To Clean the Regeneration FilterServicing the Regeneration Filter Dewpoint Control System Service Symptoms of Worn Out DesiccantTo check the dewpoint sensor and dewpoint control board First AID Desiccant Replacement ProcedureDesiccant Amounts Required Process Heater Replacement ProcedureSpots and lead to premature heater failure Regeneration Heater Replacement ProcedureRestoring a Temperature Controller to the Factory Setup Switch To select a setting 10F Process Temperature Control Error Messages Regeneration Monitor Signal Processor Error Messages Moving Between Levels Regeneration Monitor Advanced ProgrammingSetpoints HysteresisInput Shift Security Protection Sensor Input Type Scale IndicationDisplay Refresh Cycle Problem Possible Cause Corrective Action TroubleshootingProblem Possible Cause Corrective Action Problem Possible Cause Corrective Action Appendix Warranty ReturnsReturned Material Policy Credit ReturnsCfm Dryers Appendix Preventive Maintenance Checklist Dehumidifying Dryers Technical Assistance Service DepartmentParts Department Sales Department

350-2100 CFM specifications

The Sterling 350-2100 CFM is a high-performance ventilation system that effectively addresses the needs of various industrial and commercial applications. This versatile unit is designed to provide optimal air movement, offering flow rates spanning from 350 to 2100 cubic feet per minute (CFM). Its capabilities make it ideal for environments that require robust air circulation, such as warehouses, factories, and workshops.

One of the standout features of the Sterling 350-2100 CFM is its energy-efficient motor. The unit is equipped with a reliable and durable drive system, allowing for lower energy consumption while maintaining high performance. This not only reduces operational costs but also contributes to a greener footprint, making it an attractive option for businesses looking to enhance sustainability.

The ventilation system is designed with an advanced aerodynamic blade technology that maximizes airflow and minimizes noise levels. This allows for a more comfortable working environment by reducing the disruption typically associated with high-velocity air movement. Additionally, the integrated sound-dampening features ensure that it operates quietly, making it suitable for noise-sensitive areas.

The Sterling 350-2100 CFM also incorporates a user-friendly control panel, which allows for easy adjustments and monitoring of airflow levels. This system can be tailored to specific ventilation requirements, ensuring optimal performance in diverse settings. For added convenience, some models come with remote control capabilities, allowing operators to manage airflow from a distance.

Durability is a key characteristic of the Sterling 350-2100 CFM. The unit is constructed with high-grade materials that resist wear and tear, providing long-lasting service even in challenging environments. The weather-resistant design further enhances its suitability for outdoor applications.

Moreover, the system can be easily integrated with existing HVAC setups, providing flexibility and compatibility without extensive modifications. Maintenance is also simplified, with easily accessible components for routine checks and servicing.

In summary, the Sterling 350-2100 CFM ventilation system stands out for its combination of energy efficiency, quiet operation, and robust design. With its innovative technologies and user-friendly features, it meets the demands of modern industrial and commercial spaces while ensuring optimal air quality and comfort for occupants.