Presario 1400 Series
Models: XL240, XL241, XL242, XL244, XL245, XL246, XL247, XL250, XL340, XL341, XL342, XL343, XL344, XL345, XL346, XL350, XL352, XL355, and XL356
Video Test Error Codes (Continued)
Error Code
Description
ECG/VGC ROM checksum test failed.
ECG/VGC 640 x 200 graphics mode test failed.
ECG/VGC 640 x 350 16 color set test failed.
ECG/VGC 640 x 350 64 color set test failed.
ECG/VGC monochrome graphics mode test failed.
ECG/VGC monochrome graphics mode test failed.
640 x 480 graphics test failed.
320 x 200 graphics (256 color mode) test failed.
Advanced VGA Controller test failed.
Advanced VGA 256 Color test failed.
Recommended Action
The following steps apply to error codes
1.Run the Configuration and Diagnostics Utilities.
2.Disconnect external monitor and test with internal LCD display.
3.Replace the display assembly and retest.
4.Replace the system board and retest.
Video Test Error Codes (Continued)
Error Code
2458-xx
2468-xx
2477-xx
2478-xx
2480-xx
Description
Advanced VGA BitBLT tes.t Advanced VGA DAC test. Advanced VGA data path test. Advanced VGA BitBLT test. Advanced VGA LineDraw test.
Recommended Action
The following action applies to error codes
Replace the system board and retest.