SPX Cooling Technologies 1000, 1200 specifications Vibration Limit Switch

Page 25

Marley / Sigma 1000/1200 CoolingTower / Specifications: Options

Specifications

Specification Value

25

set point shall be displayed on the door of the control panel. The bypass shall include a complete magnetic bypass circuit with capability to isolate the VFD when in the bypass mode. Transfer to the bypass mode shall be automatic in the event of VFD failure or for specific trip conditions allowing safe transfer of utility voltage to the motor. Automatic bypass with an earth ground condition is not allowed. The bypass contactor shall be cycled on and off while operat- ing in bypass, to maintain the set-point temperature of the cold water. The drive design shall be operated as a stand-alone system without the need for a BMS sys- tem. Operator controls shall be mounted on the front of the enclosure and shall consist of start and stop control, bypass/ VFD selector switch, Auto/Manual selec- tor switch, manual speed control, and solid-state temperature controller. An emergency bypass selector switch inter- nal to the panel allowing the fluid cooler fan motor to be run at full speed shall be furnished. To prevent heating problems in the fluid cooler fan motor and to assure proper gear box lubrication the VFD sys- tem shall de energize the motor once 25% motor speed is reached and cool- ing is no longer required. The VFD shall include de-icing logic with auto canceling and adjustable time. Speed in De-Ice mode shall not exceed 50% motor speed. The fluid cooler manufacturer shall supply VFD start-up assistance. Tower vibration testing throughout the speed range is required to identify and lockout any natural frequency vibration levels which may exceed CTI guidelines.

Vibration Limit Switch:

5.8Add the following paragraph in the Mechanical Equipment section: A single-pole,double-throw vibration limit switch in a NEMA 4 housing shall be installed on the mechanical equipment support for wiring into the owner’s control panel. The purpose of this switch will be to interrupt power to the motor in the event of excessive vibra- tion. It shall be adjustable for sensitiv- ity, and shall require manual reset.

Unless specified otherwise, a Metrix switch will be provided. A double-pole, double-throw model is also available. If purchased in conjunction with the Control System, it is also factory-wired. The requirement for manual reset assures that the tower will be visited to determine the cause of excess vibration.

Image 25
Contents Marley Sigma 1000/1200 Cooling Tower Marley / Sigma 1000/1200 CoolingTower / Table of Contents Marley / Sigma 1000/1200 CoolingTower Tower Endwall ElevationWidth Height Maximum Static ModelPlan Dimensions ModelMarley / Sigma 1000 CoolingTower / Engineering Data Support Operating Weigt lb Model Flat Basin SectionWidth Length Height Maximum Static Model Endwall HElevationEndwall Elevation G Dimensions Model Per CellMarley / Sigma 1200 CoolingTower / Engineering Data Support Operating Weight lb Model Single Cell Each Cell Add Variable Speed Control Two-Speed MotorsEnclosures System CleanlinessSound Control Base Marley / Sigma 1000/1200 CoolingTower / Specifications BaseUnder no circumstances should you allow the manufacturer to Thermal PerformanceAlty on the manufacturer Indicated below and following ConstructionWood Even in aggressive water conditions, the heavy construction Fan Deck and Fan CylinderFan guard normally precludes the need for stainless steel Unitized support normally precludes the need for stainless Mechanical EquipmentSteel Fill, Louvers and Drift Eliminators Hot Water Distribution System AccessCasing Scope of Work Cold Water Collection BasinSpecifications Specification Value Basin Heater Marley Premium VFD System Vibration Limit Switch Ladder Safety Cage Convenience and Safety Options StairwayPlenum Walkway Ladder ExtensionMiscellaneous Options Wood Cold Water Basin Oil Level Sight GlassRedwood Components Hot Water Basin CoversLow Noise Tower Watertight Partitions Between Cells Fire Safety OptionsPage Page West 129 Street Overland PARK, Kansas 66213 United States
Related manuals
Manual 12 pages 20.61 Kb

1000, 1200 specifications

SPX Cooling Technologies, a prominent player in the cooling solutions market, is known for its cutting-edge designs and innovations in the field of cooling systems. Among its notable offerings are the SPX Cooling Technologies 1200 and 1000 series, which are engineered to meet the demands of various industrial applications.

The SPX Cooling Technologies 1200 series is renowned for its efficiency and robust construction. One of its main features is its modular design, allowing for easy installation and maintenance. This series is equipped with advanced cooling technology, enhancing energy efficiency while minimizing operating costs. The 1200 series utilizes a counterflow design, promoting improved heat exchange and a more direct airflow pattern. This results in higher thermal performance and reduced energy consumption, making it an ideal choice for operations that prioritize sustainability and cost-effectiveness.

On the other hand, the SPX Cooling Technologies 1000 series is tailored for versatility and reliability. This series boasts a design that accommodates a range of capacities and configurations, making it suitable for diverse applications, including HVAC, industrial processes, and power generation. One of the standout characteristics of the 1000 series is its handling of large thermal loads with minimal pressure drop, which ensures optimal performance in challenging conditions. Its corrosion-resistant materials enhance durability, making it resilient in harsh environments.

Both series incorporate advanced fan technology, which is designed to maximize airflow while minimizing noise levels. The fans are individually controllable, allowing for precise adjustments to meet specific cooling demands. Furthermore, these cooling towers are designed with user-friendly accessibility, simplifying maintenance and inspection processes, thereby reducing downtime.

SPX Cooling Technologies also places a significant emphasis on innovation. Both the 1200 and 1000 series are built with predictive maintenance capabilities, leveraging IoT technologies to monitor performance metrics in real time. This proactive approach enables facility managers to anticipate maintenance needs and address issues before they escalate into costly failures.

In summary, the SPX Cooling Technologies 1200 and 1000 series represent a substantial advancement in cooling technology, providing efficient, reliable, and modular solutions for various industrial applications. Their design, efficiency, and advanced features position them as leaders in the market, responding to the evolving needs of industries worldwide.