SPX Cooling Technologies 1200, 1000 Endwall Elevation, Tower, Width, Height Maximum Static Model

Page 4

Marley / Sigma 1000 CoolingTower / Engineering Data : Schematic

4

C DIA. FAN

PLAN

W OUT TO OUT OF TOWER

 

 

 

 

CL COL.

 

CL COL.

COL.CL

 

 

 

 

 

 

5"

 

A BAYS @ 4'-0 = L

5"

 

 

 

 

 

 

TOP OF

 

 

 

 

 

 

 

 

FAN CYLINDER

 

 

 

 

 

 

 

 

B

TOP OF

 

 

 

 

 

 

 

 

FAN DECK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Endwall

 

 

 

 

 

 

 

H

Elevation

 

 

 

 

 

 

 

 

BASE OF

 

 

 

 

 

 

 

 

 

TOWER COLUMNS

 

 

Tower

GPM

Width

Length

Height

A

B

C

Maximum

Static

Model

per cell

W

L

H

Motor hp

Lift

 

 

 

1011

380 - 2140

21'-5"

8'-0"

11'-858"

2

3'-8"

84"

30

11.7'

1021

580 - 3220

21'-5"

12'-0"

11'-858"

3

3'-5"

96"

30

11.7'

1031

580 - 3220

23'-9"

12'-0"

11'-858"

3

3'-8"

120"

50

11.7'

1041

790 - 4300

26'-0"

16'-0"

11'-858"

4

4'-0"

144"

60

11.7'

NOTE

1Last number of model indicates number of cells. Change as appropriate for your selection. Primary engineering data is per cell.

2Fan hp is usually less than shown here.

3Height shown is from base of tower columns to fan deck. Wood basin, if used, elevates tower 614". If concrete basin is used, subtract 1'-6" for height above top of basin curb.

Image 4
Contents Marley Sigma 1000/1200 Cooling Tower Marley / Sigma 1000/1200 CoolingTower / Table of Contents Marley / Sigma 1000/1200 CoolingTower Endwall Elevation TowerWidth Height Maximum Static ModelDimensions Model PlanMarley / Sigma 1000 CoolingTower / Engineering Data Support Flat Basin Section Operating Weigt lb ModelEndwall HElevation Width Length Height Maximum Static ModelDimensions Model Per Cell Endwall Elevation GMarley / Sigma 1200 CoolingTower / Engineering Data Support Operating Weight lb Model Single Cell Each Cell Add Two-Speed Motors Variable Speed ControlEnclosures System CleanlinessSound Control Marley / Sigma 1000/1200 CoolingTower / Specifications Base BaseUnder no circumstances should you allow the manufacturer to Thermal PerformanceAlty on the manufacturer Indicated below and following ConstructionWood Even in aggressive water conditions, the heavy construction Fan Deck and Fan CylinderFan guard normally precludes the need for stainless steel Unitized support normally precludes the need for stainless Mechanical EquipmentSteel Fill, Louvers and Drift Eliminators Hot Water Distribution System AccessCasing Cold Water Collection Basin Scope of WorkSpecifications Specification Value Basin Heater Marley Premium VFD System Vibration Limit Switch Convenience and Safety Options Stairway Ladder Safety CagePlenum Walkway Ladder ExtensionOil Level Sight Glass Miscellaneous Options Wood Cold Water BasinRedwood Components Hot Water Basin CoversLow Noise Tower Fire Safety Options Watertight Partitions Between CellsPage Page West 129 Street Overland PARK, Kansas 66213 United States
Related manuals
Manual 12 pages 20.61 Kb

1000, 1200 specifications

SPX Cooling Technologies, a prominent player in the cooling solutions market, is known for its cutting-edge designs and innovations in the field of cooling systems. Among its notable offerings are the SPX Cooling Technologies 1200 and 1000 series, which are engineered to meet the demands of various industrial applications.

The SPX Cooling Technologies 1200 series is renowned for its efficiency and robust construction. One of its main features is its modular design, allowing for easy installation and maintenance. This series is equipped with advanced cooling technology, enhancing energy efficiency while minimizing operating costs. The 1200 series utilizes a counterflow design, promoting improved heat exchange and a more direct airflow pattern. This results in higher thermal performance and reduced energy consumption, making it an ideal choice for operations that prioritize sustainability and cost-effectiveness.

On the other hand, the SPX Cooling Technologies 1000 series is tailored for versatility and reliability. This series boasts a design that accommodates a range of capacities and configurations, making it suitable for diverse applications, including HVAC, industrial processes, and power generation. One of the standout characteristics of the 1000 series is its handling of large thermal loads with minimal pressure drop, which ensures optimal performance in challenging conditions. Its corrosion-resistant materials enhance durability, making it resilient in harsh environments.

Both series incorporate advanced fan technology, which is designed to maximize airflow while minimizing noise levels. The fans are individually controllable, allowing for precise adjustments to meet specific cooling demands. Furthermore, these cooling towers are designed with user-friendly accessibility, simplifying maintenance and inspection processes, thereby reducing downtime.

SPX Cooling Technologies also places a significant emphasis on innovation. Both the 1200 and 1000 series are built with predictive maintenance capabilities, leveraging IoT technologies to monitor performance metrics in real time. This proactive approach enables facility managers to anticipate maintenance needs and address issues before they escalate into costly failures.

In summary, the SPX Cooling Technologies 1200 and 1000 series represent a substantial advancement in cooling technology, providing efficient, reliable, and modular solutions for various industrial applications. Their design, efficiency, and advanced features position them as leaders in the market, responding to the evolving needs of industries worldwide.