Jenn-Air W10379136A Fully Integrated Installation Requirements, Airflow Venting Requirements

Models: W10379136A

1 72
Download 72 pages 2.24 Kb
Page 11
Image 11

Fully Integrated Installation Requirements

The refrigerator can be installed fully integrated if the adjacent cabinetry meets the airflow venting requirements critical to refrigerator performance.

IMPORTANT:

Both Standard and Fully Integrated installations can be achieved with either a 24" (60.9 cm) or 25" (63.5 cm) deep opening.

A full height grille is used to achieve a fully integrated installation. Use the integrated bracket (provided with refrigerator) to attach the full height grille.

NOTE: A top grille filler is not required with a full height grille.

Integrated Grille Bracket

Fully Integrated Installation - Side View

A

B

C

D

A. False front (optional)

C. Full height grille

B. Airflow

D. Door panel

Airflow Venting Requirements

Fully integrated installations require a minimum of 6" (15.24 cm) of open space above the refrigerator. This space must not be blocked in any way, including soffits.

Option 1 - Open to Ceiling

6" (15.24 cm)

min.

84"

(213.4 cm)

11

Page 11
Image 11
Jenn-Air W10379136A Fully Integrated Installation Requirements, Airflow Venting Requirements, Option 1 Open to Ceiling