Jenn-Air W10379136A manual Location Requirements, Opening Dimensions

Models: W10379136A

1 72
Download 72 pages 2.24 Kb
Page 7
Image 7

Location Requirements

 

 

 

WARNING

 

 

 

 

 

 

80" - 90"

 

 

 

(203-229 cm)

B

 

 

 

 

 

 

 

 

Dimension

Explosion Hazard

 

 

 

 

Keep flammable materials and vapors, such as

 

 

 

 

gasoline, away from refrigerator.

 

 

 

 

Failure to do so can result in death, explosion, or fire.

84" (213.4 cm)

 

 

 

 

 

 

to bottom of solid soffit

 

IMPORTANT:

 

 

 

 

Observe all governing codes and ordinances.

 

 

 

 

It is recommended that you do not install the refrigerator near

 

 

 

 

an oven, radiator, or other heat source.

 

 

 

77"

Do not install in a location where the temperature will fall

 

 

 

 

 

 

(196 cm)

below 55°F (13°C).

 

 

 

 

Floor must support the refrigerator weight, more than 600 lbs

 

 

A

 

(272 kg), door panels and contents of the refrigerator.

 

 

 

Ceiling height must allow for side tipping radius. See “Tipping

 

 

Width

 

 

(see chart following)

 

Radius.”

 

 

 

 

Location should permit door to open fully. See “Door Swing

 

 

 

 

Dimensions.”

 

 

 

 

Location must permit top grille removal. See “Opening

 

 

 

 

Dimensions.”

 

 

 

 

Opening Dimensions

 

 

 

 

The width of the opening, from side to side, must be as

 

 

 

 

specified for your model, for at least 2" (5.08 cm) back from

 

 

 

 

the face of the cabinet.

 

C

1"

 

 

 

 

 

NOTE: If your opening does not meet this requirement, you

6"

 

(2.54 cm)

6"

will need to make modifications.

(15.2 cm)

 

 

(15.2 cm)

 

 

 

 

A solid soffit or wall cabinet must be installed 84" (213.4 cm) above the floor. If the solid soffit is higher than 84" (213.4 cm) or one is not available, then the refrigerator must be braced.

If the anti-tip boards are needed, they must be attached to the rear wall studs so that there is 84" (213.4 cm) from the bottom of the anti-tip board to the floor. See “Install Anti-Tip Boards” for more information.

For a fully integrated installation, a minimum of 6" (15.24 cm) of open space above the refrigerator is required. See “Fully Integrated Installation.” Anti-tip boards are required. See “Install Anti-Tip Boards” for more information.

A grounded 3 prong electrical outlet should be located within a specified number of inches from the right-hand side cabinets or end panel. See the chart following the graphic for the number of inches required for your model. For more information, see “Electrical Requirements.”

The water shutoff should be located in the base cabinet on either side of the refrigerator or some other easily accessible area. If the water shutoff valve is not in the cabinets, the plumbing for the water line can come through the floor. See “Water Supply Requirements” for more information.

 

Model

Width A (as shown

 

Dimension B (as

 

 

above)

 

shown above)

 

 

 

 

 

 

42

42" (106.7 cm)

 

10" (25.4 cm)

 

48

48" (121.9 cm)

 

16" (40.6 cm)

 

 

 

 

 

 

 

 

 

Installation Type

Depth C (as shown above)

 

 

 

 

Standard Flush

25" (63.5 cm) minimum

 

(new installation)

 

 

 

 

 

 

Retrofit Installations

24" (60.9 cm) minimum

 

 

 

 

 

IMPORTANT:

The width of the opening (Width A), must be as specified for your model, for at least 2" (5.08 cm) back from the face of the cabinet.

NOTE: If your opening does not meet this requirement, you will need to make modifications.

Flooring under refrigerator must be at same level as the room. Face of cabinetry must be plumb.

7

Page 7
Image 7
Jenn-Air W10379136A Location Requirements, Opening Dimensions, Model Width a as shown Dimension B as Above Shown above