Roberts Gorden BH Series ROBERTS-GORDON will not PAY for, Warranty is Void if, Canada

Page 41

ROBERTS GORDON ® BH-SERI E S SUBM IT TAL SHE E T

THE ROBERTS GORDON® GORDONRAY® BH LIMITED WARRANTY

ROBERTS-GORDON WILL PAY FOR:

Within 42 months from date of shipment from Roberts- Gordon, replacement parts will be provided free of charge for any part of the controller which fails due to a manufacturing or material defect.

Roberts-Gordon will require the part in question to be returned to the factory. Roberts-Gordon will, at its sole discretion, repair or replace after determining the nature of the defect and disposition of part in question.

ROBERTS GORDON® Replacement Parts are warranted for a period of 18 months from date of shipment from Roberts-Gordon or the remaining ROBERTS GORDON® GORDONRAY® BH warranty.

ROBERTS-GORDON WILL NOT PAY FOR:

Service trips, service calls and labor charges. Shipment of replacement parts.

Claims where the total price of the goods have not been paid.

Damage due to:

Improper installation, operation or maintenance.

Misuse, abuse, neglect, or modification of the ROBERTS GORDON® GORDONRAY® BH in any way.

Use of the ROBERTS GORDON® GORDONRAY® BH for other than its intended purpose.

Incorrect gas or electrical supply, accident, fire, floods, acts of God, war, terrorism, or other casualty.

Improper service, use of replacement parts or accessories not specified by Roberts-Gordon.

Failure to install or maintain the ROBERTS GOR- DON® GORDONRAY® BH as directed in the Instal- lation, Operation and Service manual.

Relocation of the ROBERTS GORDON® GORDON- RAY® BH after initial installation

The use of the ROBERTS GORDON® GORDON- RAY® BH in a corrosive atmosphere containing con- taminants.

The use of the ROBERTS GORDON® GORDON- RAY® BH in the vicinity of a combustible or explo- sive material.

Any defect in the ROBERTS GORDON® GORDON- RAY® BH arising from a drawing, design, or specifi- cation supplied by or on behalf of the consumer.

Damage incurred during shipment. Claim must be filed with carrier.

The ownership of the ROBERTS GORDON® GORDONRAY® BH is moved or transferred. This warranty is nontransferable.

Roberts-Gordon is not permitted to inspect the damaged controller and/or component parts.

READ YOUR INSTALLATION, OPERATION AND SERVICE MANUAL

If you have questions about your controller, contact your installing professional. Should you need Replacement Parts or have additional questions, call or write Roberts- Gordon:

U.S.A.

1250 William Street P.O. Box 44

Buffalo, New York 14240-0044 716.852.4400

Canada

76 Main Street West, Unit 10 Grimsby, Ontario L3M 1R6 905.945.5403

On the web at: www.rg-inc.com

Roberts-Gordon's liability, and your exclusive remedy, under this warranty or any implied warranty (including the implied warranties of merchantability and fitness for a particular purpose) is limited to providing replacement parts during the term of this warranty. Some jurisdictions do not allow limitations on how long an implied warranty lasts, so this limitation may not apply to you. There are no rights, warranties or conditions, expressed or implied, statutory or otherwise, other than those contained in this warranty.

Roberts-Gordon shall in no event be responsible for incidental or consequential damages or incur liability for damages in excess of the amount paid by you for the ROBERTS GORDON® GORDONRAY® BH. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so this limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from jurisdiction to jurisdiction.

Roberts-Gordon shall not be responsible for failure to perform under the terms of this warranty if caused by circumstances out of its control, including but not limited to war, fire, flood, strike, government or court orders, acts of God, terrorism, unavailability of supplies, parts or power. No person is authorized to assume for Roberts-Gordon any other warranty, obligation or liability.

WARRANTY IS VOID IF:

The ROBERTS GORDON® GORDONRAY® BH is not installed by an contractor qualified in the installation and service of gas-fired heating equipment.

You cannot prove original purchase date and required annual maintenance history.

The data plate and/or serial number are removed, defaced, modified or altered in any way.

LIMITATIONS ON AUTHORITY OF

REPRESENTATIVES:

No representative of Roberts-Gordon, other than an Executive Officer, has authority to change or extend these provisions. Changes or extensions shall be binding only if confirmed in writing by Roberts-Gordon's duly authorized Executive Officer.

© 2004 Roberts-Gordon

BEFORE IN STALLATI ON AND OPER ATI ON OF HEATI NG EQUIPMENT, READ AND U NDERSTAND THE INSTALLATION, OPERATIO N AND SERVICE MANUAL .

APPLICATION S, ENGI NEERING AND DETAI LED GUID ANCE ON SYSTEMS DESIGN, INSTALLATI ON AND PRODUCT PERFORMANCE IS AVAI LABLE UPON REQUEST. ROBERTS GORDON® PRODUCTS ARE TO BE

 

INSTALLED ONLY IN ACCORDANCE WI TH LOCAL LAWS, CODES AND REGULATIONS, AND ONLY BY A CONTRACTOR QUALI FIED I N THE I NSTALLATION AND SERVICE OF GAS-FIRED HEATING EQUI PMENT.

Image 41
Contents Copyright 2004 Roberts-Gordon N170601NA Rev D 07/04 Roberts-Gordon2004 Contents of Core and Extension Packages Standard Parts ListContents of BH-Series Burner Carton General Specifications Standard Reflector Inches Centimeters Model Clearances to CombustiblesOne Side Reflector Inches Centimeters Two Side Reflectors Inches CentimetersInches Centimeters Tilt Reflector Inches CentimetersTube, Full Inches Centimeters Model ModelLower Clearance Shield Inches Centimeters Tube, Opposite 45 Reflector Inches Centimeters ModelBH-80 153 166 BH-40 BH-60 138 150BH-40 Venting InchesVent BH-60 Infrared Tubes Pipes BH-80 BH-100 BH-115/125 BH-140/150 BH-175/200BH-SERIES Assembly Overview BH-Series Linear Assembly Overview Critical Hanger Placement Heater InstallationBH-Series Linear Layout Overview Weld Must be to the bottom of the tube Burner Tube InstallationBurner Tube Hook 91907302 Tube/Reflector Hanger 03090100Coupling and Tube Assembly Tube Clamp Package InstallationOpen ClosedTighten slide bar as shown below Correct Slide DimensionsPosition 229 cm ± 305 25 cm Total Overall Tube LengthHanger Burner Tube Reflector Turbulator InstallationReflector Installation Overlap must be a Minimum of 6 16 cm Reflector, U-Clip and Reflector Support InstallationScrew Reflector SupportExtra chain min 12 30 cm Burner Gasket Lock Burner InstallationHook Burner Tube Bolt Torque 120 Bolt 94273914 BurnerBH-Series U-Tube Assembly Overview Optional Heater AccessoriesTube, Standard Tube, FullBH-Series U-Tube Layout Overviews BH-175 BH-200 BH-140 BH-150 BH-175 BH-200Tube Coupling Elbow Package Configuration Elbow InstallationReflector Joint Installation Attach Reflector Joint Reflector Joint DetailJoint Reflector Side Extension Bracket InstallationSide Reflector Installation Shield Support Strap Assembly Lower Clearance Shield InstallationTWO-FOOT Decorative Grille Installation Grille InstallationShield Frame Shield InstallationReflector Side Extension Installation One-Foot Decorative Grille Bracket ONE-FOOT Decorative Grille InstallationDecorative Grille Joint Piece and ReinforcementElbow End Piece and Reflector End CapReflector joint piece End PieceSilicone Cap Installation Protective Grille InstallationHorizontal Ventilation 4 10 cm Pipe VentingVertical Ventilation 4 10 cm Pipe Combustible or Non-Combustible Wall OnlyTjernlund VH1-6 or Equivalent Common Sidewall VentingOutside Wall Vent Terminal 6 15 cm 90502101Top View Roberts-Gordon Common Vertical VentingVent Cap 4 10 cm 90502300 Vertical Outside Air Supply for Single Heater InstallationOutside Combustion AIR Supply Vent Cap Vertical Outside Air Supply for Double Heater InstallationVent Cap Wall Outside Vent Cap 6 15 cm 90502302Shown without blower assembly Gas Connection with Stainless Steel Flex ConnectorGAS Piping Shut-Off ValveLine Voltage Thermostat Wiring WiringBurners Maximum 5 BurnersSpdt Transformer Relay Low Voltage Thermostat WiringLow Voltage Thermostat BlackBH-Series Ladder Diagram BH-Series Internal WiringBlower Transformer Pressure Switch Gap Electrode Ground Power Sense Spark Valve Ignition Module Gas ValveElectrical Connection to the Burner Pressure Switch Internal Burner DiagramROBERTS-GORDON will not PAY for Warranty is Void ifLimitations on Authority Representatives Canada