Roberts Gorden BH Series service manual Roberts-Gordon

Page 1

GordonRay® BH

The Economical, Unitary Infrared Heater

Submittal: BH Series

 

 

Job:

 

 

 

 

 

 

Location:

 

 

 

 

 

 

 

Engineer:

 

 

 

 

 

 

 

Gas Specs:

 

 

 

 

 

 

 

 

Date:

 

 

 

 

 

 

QTY.

 

MODEL NO. BH

 

UNIT INPUT

 

BTU/HR

 

 

 

 

 

 

 

 

QTY.

 

MODEL NO. BH

 

UNIT INPUT

 

BTU/HR

 

 

 

 

 

 

 

 

QTY.

 

MODEL NO. BH

 

UNIT INPUT

 

BTU/HR

 

 

 

 

 

 

 

 

QTY.

 

MODEL NO. BH

 

UNIT INPUT

 

BTU/HR

 

 

 

 

 

 

 

 

 

 

TOTAL INPUT

 

BTU/HR

 

 

 

 

 

 

 

 

 

 

 

Important

Before installation and operation of heating equipment, read and understand the

Installation, Operation and Service Manual.

Applications, engineering and detailed guidance on systems design, installation and product performance is available upon request.

ROBERTS GORDON® products are to be installed only in accordance with local laws, codes and regulations, and only by a contractor qualified in the installation and service of gas-fired heating equipment.

Roberts-Gordon

Roberts-Gordon

1250 William Street

76 Main Street West, Unit 10

P.O. Box 44

Grimsby, Ontario L3M 1R6

Buffalo, New York 14240-0044

Canada

Telephone: 716.852.4400

Telephone: 905.945.5403

Fax: 716.852.0854

Fax: 905.945.0511

Toll Free: 800.828.7450

 

www.rg-inc.com

 

© Copyright 2004 Roberts-Gordon

P/N170601NA Rev D 07/04

Image 1
Contents Copyright 2004 Roberts-Gordon N170601NA Rev D 07/04 Roberts-Gordon2004 Contents of BH-Series Burner Carton Standard Parts ListContents of Core and Extension Packages General Specifications Standard Reflector Inches Centimeters Model Clearances to CombustiblesOne Side Reflector Inches Centimeters Two Side Reflectors Inches CentimetersInches Centimeters Tilt Reflector Inches CentimetersTube, Full Inches Centimeters Model ModelLower Clearance Shield Inches Centimeters Tube, Opposite 45 Reflector Inches Centimeters ModelBH-80 153 166 BH-40 BH-60 138 150BH-40 Venting InchesVent BH-60 Infrared Tubes Pipes BH-80 BH-100 BH-115/125 BH-140/150 BH-175/200BH-SERIES Assembly Overview BH-Series Linear Assembly Overview Critical Hanger Placement Heater InstallationBH-Series Linear Layout Overview Weld Must be to the bottom of the tube Burner Tube InstallationBurner Tube Hook 91907302 Tube/Reflector Hanger 03090100Coupling and Tube Assembly Tube Clamp Package InstallationOpen ClosedTighten slide bar as shown below Correct Slide DimensionsPosition 229 cm ± 305 25 cm Total Overall Tube LengthReflector Installation Turbulator InstallationHanger Burner Tube Reflector Overlap must be a Minimum of 6 16 cm Reflector, U-Clip and Reflector Support InstallationScrew Reflector SupportExtra chain min 12 30 cm Burner Gasket Lock Burner InstallationHook Burner Tube Bolt Torque 120 Bolt 94273914 BurnerBH-Series U-Tube Assembly Overview Optional Heater AccessoriesTube, Standard Tube, FullBH-Series U-Tube Layout Overviews BH-175 BH-200 BH-140 BH-150 BH-175 BH-200Reflector Joint Installation Elbow Package Configuration Elbow InstallationTube Coupling Joint Reflector Joint DetailAttach Reflector Joint Side Reflector Installation Bracket InstallationReflector Side Extension Shield Support Strap Assembly Lower Clearance Shield InstallationTWO-FOOT Decorative Grille Installation Grille InstallationReflector Side Extension Installation Frame Shield InstallationShield One-Foot Decorative Grille Bracket ONE-FOOT Decorative Grille InstallationDecorative Grille Joint Piece and ReinforcementElbow End Piece and Reflector End CapReflector joint piece End PieceSilicone Cap Installation Protective Grille InstallationHorizontal Ventilation 4 10 cm Pipe VentingVertical Ventilation 4 10 cm Pipe Combustible or Non-Combustible Wall OnlyTjernlund VH1-6 or Equivalent Common Sidewall VentingOutside Wall Vent Terminal 6 15 cm 90502101Top View Roberts-Gordon Common Vertical VentingOutside Combustion AIR Supply Vertical Outside Air Supply for Single Heater InstallationVent Cap 4 10 cm 90502300 Vent Cap Vertical Outside Air Supply for Double Heater InstallationVent Cap Wall Outside Vent Cap 6 15 cm 90502302Shown without blower assembly Gas Connection with Stainless Steel Flex ConnectorGAS Piping Shut-Off ValveLine Voltage Thermostat Wiring WiringBurners Maximum 5 BurnersSpdt Transformer Relay Low Voltage Thermostat WiringLow Voltage Thermostat BlackBH-Series Ladder Diagram BH-Series Internal WiringBlower Transformer Pressure Switch Gap Electrode Ground Power Sense Spark Valve Ignition Module Gas ValveElectrical Connection to the Burner Pressure Switch Internal Burner DiagramROBERTS-GORDON will not PAY for Warranty is Void ifLimitations on Authority Representatives Canada