Roberts Gorden BH Series Optional Heater Accessories, BH-Series U-Tube Assembly Overview

Page 19

ROBERTS GOR DON® BH-SERI E S SUBM IT TAL SHE E T

OPTIONAL HEATER ACCESSORIES

BH-Series U-Tube Assembly Overview

Burner

Vent Adapter

U-Tube

Support Bracket

Reflector

Support

Turbulator with select models

Reflector

Tube Clamp

Package

U-Tube, Standard

12

Burner

Tube

Tube

Couplings

U-Clips Reflector

U-Tube, Full 45°

1

2

Tight U-Bolt

Loose U-Bolt

14" (10 cm) U-Bolt,

2 4" (10 cm) U-Bolt,

secured to Burner Tube

secured to Bracket with

with 1/4" (6 mm)

1/4" (6 mm) Lockwashers

Lockwashers and

and 1/4-20 Hex Nuts on

1/4-20 Hex Nuts

top and bottom to

 

allow for tube expansion

 

and contraction

End Caps

U-Tube

18" (457 mm)

Center to Center

U-Tube, Opposite 45°

12

U-Bolt

Nut

Lock Washer

Lock Washer

Nut

© 2004 Roberts-GordonBEFORE IN STALLATI ON AND OPER ATI ON OF HEATI NG EQUIPMENT, READ AND U NDERSTAND THE INSTALLATION, OPERATIO N AND SERVICE MANUAL .

APPLICATION S, ENGI NEERING AND DETAI LED GUID ANCE ON SYSTEMS DESIGN, INSTALLATI ON AND PRODUCT PERFORMANCE IS AVAI LABLE UPON REQUEST. ROBERTS GORDON® PRODUCTS ARE TO BE INSTALLED ONLY IN ACCORDANCE WI TH LOCAL LAWS, CODES AND REGULATIONS, AND ONLY BY A CONTRACTOR QUALI FIED I N THE I NSTALLATION AND SERVICE OF GAS-FIRED HEATING EQUI PMENT.

Image 19
Contents Copyright 2004 Roberts-Gordon N170601NA Rev D 07/04 Roberts-Gordon2004 Contents of BH-Series Burner Carton Standard Parts ListContents of Core and Extension Packages General Specifications Two Side Reflectors Inches Centimeters Clearances to CombustiblesStandard Reflector Inches Centimeters Model One Side Reflector Inches CentimetersModel Tilt Reflector Inches CentimetersInches Centimeters Tube, Full Inches Centimeters ModelBH-40 BH-60 138 150 Tube, Opposite 45 Reflector Inches Centimeters ModelLower Clearance Shield Inches Centimeters BH-80 153 166BH-100 BH-115/125 BH-140/150 BH-175/200 Venting InchesBH-40 Vent BH-60 Infrared Tubes Pipes BH-80BH-SERIES Assembly Overview BH-Series Linear Assembly Overview Critical Hanger Placement Heater InstallationBH-Series Linear Layout Overview Hook 91907302 Tube/Reflector Hanger 03090100 Burner Tube InstallationWeld Must be to the bottom of the tube Burner TubeClosed Tube Clamp Package InstallationCoupling and Tube Assembly Open229 cm ± 305 25 cm Total Overall Tube Length Correct Slide DimensionsTighten slide bar as shown below PositionReflector Installation Turbulator InstallationHanger Burner Tube Reflector Reflector Support Reflector, U-Clip and Reflector Support InstallationOverlap must be a Minimum of 6 16 cm ScrewBolt 94273914 Burner Burner InstallationExtra chain min 12 30 cm Burner Gasket Lock Hook Burner Tube Bolt Torque 120Tube, Full Optional Heater AccessoriesBH-Series U-Tube Assembly Overview Tube, StandardBH-Series U-Tube Layout Overviews BH-175 BH-200 BH-140 BH-150 BH-175 BH-200Reflector Joint Installation Elbow Package Configuration Elbow InstallationTube Coupling Joint Reflector Joint DetailAttach Reflector Joint Side Reflector Installation Bracket InstallationReflector Side Extension Grille Installation Lower Clearance Shield InstallationShield Support Strap Assembly TWO-FOOT Decorative Grille InstallationReflector Side Extension Installation Frame Shield InstallationShield Joint Piece and Reinforcement ONE-FOOT Decorative Grille InstallationOne-Foot Decorative Grille Bracket Decorative GrilleEnd Piece End Piece and Reflector End CapElbow Reflector joint pieceSilicone Cap Installation Protective Grille InstallationCombustible or Non-Combustible Wall Only VentingHorizontal Ventilation 4 10 cm Pipe Vertical Ventilation 4 10 cm PipeVent Terminal 6 15 cm 90502101 Common Sidewall VentingTjernlund VH1-6 or Equivalent Outside WallTop View Roberts-Gordon Common Vertical VentingOutside Combustion AIR Supply Vertical Outside Air Supply for Single Heater InstallationVent Cap 4 10 cm 90502300 Vent Cap 6 15 cm 90502302 Vertical Outside Air Supply for Double Heater InstallationVent Cap Vent Cap Wall OutsideShut-Off Valve Gas Connection with Stainless Steel Flex ConnectorShown without blower assembly GAS PipingMaximum 5 Burners WiringLine Voltage Thermostat Wiring BurnersBlack Low Voltage Thermostat WiringSpdt Transformer Relay Low Voltage ThermostatGround Power Sense Spark Valve Ignition Module Gas Valve BH-Series Internal WiringBH-Series Ladder Diagram Blower Transformer Pressure Switch Gap ElectrodeElectrical Connection to the Burner Pressure Switch Internal Burner DiagramCanada Warranty is Void ifROBERTS-GORDON will not PAY for Limitations on Authority Representatives