Bearing Housing and Connecting Rod

Bearing Housing and Connecting Rod

Removal

WARNING

Read Skin Injection Hazard, page 3; Burn Hazard, page 4

1.Relieve pressure; page 5.

2.FIG. 1. Remove four screws (45) and front cover (44)

3.Remove pump. Refer to Displacement Pump, Removal, page 14.

4.Remove four screws (41) and washers (42) from bearing housing (40).

5.Pull connecting rod (43) and lightly tap lower rear of bearing housing with plastic mallet to loosen from drive housing (33). Pull bearing housing and connecting rod assembly off drive housing.

6.Inspect crank (B) and connecting rod (43) for excessive wear and replace parts as needed.

Installation

1.Evenly lubricate inside of bronze bearing (C) in bearing housing (40) with high-quality motor oil. Liberally pack top roller bearing (E), lower bearing (D) inside connecting rod (43) with bearing grease.

2.Assemble connecting rod (43) to bearing housing (40). Rotate connecting rod to lowest position.

3.Clean mating surfaces of bearing and drive housings.

4.Align connecting rod with crank (B) and carefully align locating pins in drive housing (33) with holes in bearing housing (40). Push bearing housing onto drive housing or tap into place with plastic mallet.

CAUTION

DO NOT use bearing housing screws (41) to align or seat bearing housing with drive housing. Align these parts with locating pins, to avoid premature bearing wear.

5.Install screws (41) and washers (42) in bearing housing. Torque evenly to note 3 value in Fig. 1.

6.Install pump. Refer to Displacement Pump, Installation, page 14.

B

38

E 2

2

44

33D

F

43

 

42

45

1 C

41 3

 

40

87

88

 

A68

ti5739b

1Oil

2Pack with bearing grease 114819

3Torque to 25 ft-lb (34 N.m)

FIG. 1

8

311046H

Image 8
Contents Gmax II 5900 Convertible TexSpray 5900 HD Airless Sprayers Related Manuals 310892 311861 309469 308491 310894 309640Contents Manual ConventionsFire and Explosion Hazard Equipment Misuse Hazard Maintenance Pressure Relief ProcedureTroubleshooting Problem Cause SolutionReplace o-ring. Manual Removal Bearing Housing and Connecting RodInstallation Drive Housing Pinion housing 29 and locating pins BPinionHousing/Rotor/Shaft/Clutch/Pulley RemovalInstallation DimesOn/Off Switch Pressure ControlPressure Control Transducer Pressure Adjust PotentiometerControl Board Digital Display Messages Display Sprayer Operation Indication ActionDisplacement Pump Read Skin Injection Hazard, page 3 Burn Hazard,Ti6325a Attach drain hose to sprayer Parts Standard Sprayer Parts DrawingStandard Sprayer Parts List Part Description QtyEngine Detail Parts List Engine DetailPinion and Drive Housing Parts Drawing and List Premium models and TexSpray 5900HD convertiblePressure Control and Filter Parts Drawing #ONVERTIBLE #OMPLETEMPressure Control and Filter Parts List Part DescriptionQty Part Description Clutch Housing Parts Drawing and ListPart Description Ref 40 Bearing Housing Premium Sprayers Parts Drawing and ListLo-Boy Suction Set Parts Drawing and List Models 248695, 248697 Part Description QtyTechnical Data DimensionsGraco Standard Warranty For Graco Canada Customers