HEATING PERFORMANCE - Upflow, Downflow, and Horizontal Furnaces and Coils
UNIT | COIL1 |
|
|
| ARI HEATING2 |
|
|
| ||
MODEL* | MODEL |
| 47°F |
|
|
|
| 17°F |
| HSPF |
|
| MBH | COP | KW |
| MBH |
| COP | KW | STD |
| FC/MC/PC/UC18 | 17.0 | 3.26 | 1.54 |
| 9.0 |
| 2.18 | 1.23 | 7.70 |
YHJD18S21S1 | FC/MC/PC/UC24 | 17.0 | 3.26 | 1.54 |
| 9.0 |
| 2.18 | 1.23 | 7.70 |
FC/MC/PC/UC30 | 17.0 | 3.26 | 1.54 |
| 9.0 |
| 2.18 | 1.23 | 7.70 | |
|
|
| ||||||||
| HC18 | 17.0 | 3.26 | 1.54 |
| 9.0 |
| 2.18 | 1.23 | 7.70 |
| FC/MC/PC/UC24 | 23.0 | 3.72 | 1.82 |
| 12.0 |
| 2.44 | 1.47 | 7.70 |
| FC/MC/PC/UC30 | 23.0 | 3.72 | 1.82 |
| 12.0 |
| 2.44 | 1.47 | 7.70 |
| FC/MC/PC/UC32 | 23.0 | 3.72 | 1.82 |
| 12.0 |
| 2.44 | 1.47 | 7.70 |
| FC/MC/PC/UC35 | 23.0 | 3.72 | 1.82 |
| 12.0 |
| 2.44 | 1.47 | 7.70 |
YHJD24S21S1 | HC30 | 23.0 | 3.72 | 1.82 |
| 12.0 |
| 2.44 | 1.47 | 7.70 |
| HC36 | 23.0 | 3.72 | 1.82 |
| 12.0 |
| 2.44 | 1.47 | 7.70 |
| HD24 | 23.0 | 3.72 | 1.82 |
| 12.0 |
| 2.44 | 1.47 | 7.70 |
| MH24S | 23.0 | 3.72 | 1.82 |
| 12.0 |
| 2.44 | 1.47 | 7.70 |
| MH30S | 23.0 | 3.72 | 1.82 |
| 12.0 |
| 2.44 | 1.47 | 7.70 |
| FC/MC/PC/UC32 | 29.0 | 3.56 | 2.40 |
| 15.0 |
| 2.24 | 1.96 | 7.70 |
| FC/MC/PC/UC35 | 29.0 | 3.56 | 2.40 |
| 15.0 |
| 2.24 | 1.96 | 7.70 |
| FC/MC/PC/UC37 | 29.0 | 3.56 | 2.40 |
| 15.0 |
| 2.24 | 1.96 | 7.70 |
| FC/MC/PC/UC43 | 29.0 | 3.56 | 2.40 |
| 15.0 |
| 2.24 | 1.96 | 7.70 |
YHJD30S21S1 | HC36 | 29.0 | 3.56 | 2.40 |
| 15.0 |
| 2.24 | 1.96 | 7.70 |
| HC42 | 29.0 | 3.56 | 2.40 |
| 15.0 |
| 2.24 | 1.96 | 7.70 |
| HD36 | 29.0 | 3.56 | 2.40 |
| 15.0 |
| 2.24 | 1.96 | 7.70 |
|
|
|
|
|
|
|
|
|
|
|
| MH24S | 29.0 | 3.56 | 2.40 |
| 15.0 |
| 2.24 | 1.96 | 7.70 |
| MH30S | 29.0 | 3.56 | 2.40 |
| 15.0 |
| 2.24 | 1.96 | 7.70 |
| FC/MC/PC/UC37 | 34.0 | 3.58 | 2.78 |
| 21.0 |
| 2.52 | 2.39 | 8.50 |
| FC/MC/PC/UC43 | 34.0 | 3.58 | 2.78 |
| 21.0 |
| 2.52 | 2.39 | 8.50 |
| FC/MC/PC/UC48 | 34.0 | 3.58 | 2.78 |
| 21.0 |
| 2.52 | 2.39 | 8.50 |
YHJD36S21S1 | FC/MC/PC/UC60 | 34.0 | 3.58 | 2.78 |
| 21.0 |
| 2.52 | 2.39 | 8.50 |
HC42 | 34.0 | 3.58 | 2.78 |
| 21.0 |
| 2.52 | 2.39 | 8.50 | |
|
|
| ||||||||
| HC60 | 34.0 | 3.58 | 2.78 |
| 21.0 |
| 2.52 | 2.39 | 8.50 |
| HD48 | 34.0 | 3.58 | 2.78 |
| 21.0 |
| 2.52 | 2.39 | 8.50 |
| HD60 | 34.0 | 3.58 | 2.78 |
| 21.0 |
| 2.52 | 2.39 | 8.50 |
| FC/MC/PC/UC48 | 42.0 | 3.52 | 3.45 |
| 25.0 |
| 2.60 | 2.81 | 8.50 |
YHJD42S21S1 | FC/MC/PC/UC60 | 42.0 | 3.52 | 3.45 |
| 25.0 |
| 2.60 | 2.81 | 8.50 |
HC60 | 42.0 | 3.52 | 3.45 |
| 25.0 |
| 2.60 | 2.81 | 8.50 | |
|
|
| ||||||||
| HD60 | 42.0 | 3.52 | 3.45 |
| 25.0 |
| 2.60 | 2.81 | 8.50 |
| FC/MC/PC/UC60 | 48.0 | 3.40 | 4.13 |
| 37.0 |
| 2.76 | 3.97 | 7.70 |
YHJD48S21S1 | FC/MC62 | 48.0 | 3.40 | 4.13 |
| 37.0 |
| 2.76 | 3.97 | 7.70 |
HC60 | 48.0 | 3.40 | 4.13 |
| 37.0 |
| 2.76 | 3.97 | 7.70 | |
|
|
| ||||||||
| HD60 | 48.0 | 3.40 | 4.13 |
| 37.0 |
| 2.76 | 3.97 | 7.70 |
YHJD60S21S1 | FC/MC62 | 58.0 | 3.46 | 4.91 |
| 40.0 |
| 2.36 | 4.90 | 7.70 |
1.Rated CFM same as for cooling.
2.Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and
no supplemental electric heat operation.
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.
— = Not Applicable.
12 | Johnson Controls Unitary Products |