York YHJD18 THRU 60 Heating Performance Data, Condensing Unit Model No, YHJD24S21S1, AHP24

Page 24
Manual background

398612-YTG-B-0608

HEATING PERFORMANCE DATA

CONDENSING UNIT MODEL NO

YHJD24S21S1

 

 

 

 

 

 

 

EVAPORATOR COIL MODEL NO

AHP24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR TEMP.

AIR TEMP.

 

 

 

 

ID CFM

 

 

 

 

 

 

 

 

 

 

 

 

 

ENTERING

ENTERING

 

600

 

 

800

 

 

1000

 

OUTDOOR UNIT

INDOOR COIL

 

 

 

 

 

 

 

 

 

MBTUH

KW

C.O.P.

MBTUH

KW

C.O.P.

MBTUH

KW

C.O.P.

 

 

 

 

 

 

 

 

 

 

 

 

60

25.6

4.23

1.77

26.9

4.47

1.76

28.3

4.70

1.76

60

 

 

 

 

 

 

 

 

 

 

70

24.4

4.09

1.75

25.8

4.41

1.71

27.3

4.75

1.68

 

 

 

 

 

 

 

 

 

 

 

 

80

23.2

3.95

1.72

24.7

4.35

1.66

26.2

4.79

1.60

 

 

 

 

 

 

 

 

 

 

 

 

60

21.8

4.46

1.43

23.1

4.90

1.38

24.3

5.35

1.33

47

 

 

 

 

 

 

 

 

 

 

70

20.6

4.03

1.51

21.9

4.20

1.56

23.2

4.40

1.61

 

 

 

 

 

 

 

 

 

 

 

 

80

19.4

3.59

1.58

20.7

3.50

1.73

22.1

3.44

1.88

 

 

 

 

 

 

 

 

 

 

 

 

60

19.5

4.10

1.39

20.8

4.54

1.34

22.0

4.99

1.29

40

 

 

 

 

 

 

 

 

 

 

70

18.6

3.76

1.46

19.8

4.12

1.42

21.0

4.49

1.38

 

 

 

 

 

 

 

 

 

 

 

 

80

17.7

3.41

1.52

18.8

3.69

1.49

19.9

3.99

1.46

 

 

 

 

 

 

 

 

 

 

 

 

60

17.3

3.95

1.28

18.0

4.15

1.27

18.7

4.34

1.26

30

 

 

 

 

 

 

 

 

 

 

70

16.0

3.54

1.33

16.8

3.73

1.33

17.6

3.93

1.32

 

 

 

 

 

 

 

 

 

 

 

 

80

14.7

3.12

1.38

15.6

3.31

1.38

16.5

3.52

1.37

 

 

 

 

 

 

 

 

 

 

 

 

60

12.8

2.71

1.38

13.5

3.16

1.25

14.1

3.68

1.12

17

 

 

 

 

 

 

 

 

 

 

70

11.7

2.67

1.28

12.4

2.98

1.21

13.0

3.33

1.14

 

 

 

 

 

 

 

 

 

 

 

 

80

10.6

2.63

1.18

11.2

2.80

1.17

11.8

2.97

1.16

 

 

 

 

 

 

 

 

 

 

 

 

60

9.5

2.67

1.04

10.7

2.92

1.07

11.9

3.16

1.10

10

 

 

 

 

 

 

 

 

 

 

70

9.2

2.50

1.08

10.1

2.71

1.09

10.9

2.91

1.10

 

 

 

 

 

 

 

 

 

 

 

 

80

8.9

2.32

1.12

9.4

2.50

1.10

9.9

2.66

1.09

 

 

 

 

 

 

 

 

 

 

 

NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

Air Handler

Coil

MBH

KW

COP

FC/MC/PC/UC24

1.00

1.00

1.00

FC/MC/PC/UC30

1.00

1.00

1.00

FC/MC/PC/UC32

1.00

1.00

1.00

FC/MC/PC/UC35

1.00

1.00

1.00

HC30

1.00

1.00

1.00

HC36

1.00

1.00

1.00

HD24

1.00

1.00

1.00

MH24S

1.00

1.00

1.00

MH30S

1.00

1.00

1.00

AHP30

1.00

1.00

1.00

AV24

0.97

1.08

0.92

FPFP030

1.00

1.00

1.00

MV12B

FC/MC24B

0.98

1.07

0.93

MA08B

FC/MC24B

1.00

1.00

1.00

MV12B

FC/MC30B

0.98

1.07

0.93

MA08B

FC/MC30B

1.00

1.00

1.00

MV12B

FC/MC35B

0.97

1.07

0.93

MA08B

FC/MC35B

1.00

1.00

1.00

Variable Speed

Coil

MBH

KW

COP

Furnace

 

 

 

 

PV8*A12

FC/MC/PC/UC24A

0.98

1.05

0.95

PV9*A12

FC/MC/PC/UC24A

0.98

1.04

0.96

P(C,V)9*B12

FC/MC/PC/UC24B

0.98

1.05

0.95

PV8*A12

FC/MC/PC/UC30A

0.98

1.05

0.95

PV9*A12

FC/MC/PC/UC30A

0.98

1.05

0.95

P(C,V)9*B12

FC/MC/PC/UC30B

0.98

1.05

0.95

PV8*A12

FC/MC/PC/UC32A

0.98

1.05

0.95

PV9*A12

FC/MC/PC/UC32A

0.98

1.05

0.95

P(C,V)9*B12

FC/MC/PC/UC35B

0.98

1.05

0.95

PV8*A12

HC30

0.98

1.05

0.95

PV9*A12

HC30

0.98

1.05

0.95

P(C,V)9*B12

HC36

0.98

1.05

0.95

24

Johnson Controls Unitary Products

Image 24
Contents WARRANTY FEATURESDESCRIPTION 1.5 THRU 5 NOMINAL TONS, 1 PHASEPhysical and Electrical Data 398612-YTG-B-0608request 398612-YTG-B-0608 Johnson Controls Unitary ProductsOutdoor Unit Required Orifice or TXVPROCEDURES 398612-YTG-B-0608Outdoor Unit Required Orifice or TXVCOOLING CAPACITY - With Air Handler Coils 398612-YTG-B-0608Johnson Controls Unitary Products 398612-YTG-B-0608 398612-YTG-B-0608 Johnson Controls Unitary ProductsCOOLING CAPACITY - With Variable Speed Furnaces 398612-YTG-B-0608398612-YTG-B-0608 Johnson Controls Unitary ProductsHEATING PERFORMANCE - With Air Handler HEATING PERFORMANCE - With Air Handler Continued 398612-YTG-B-0608Johnson Controls Unitary Products FC/MC/PC/UC18 HEATING CAPACITY - With Variable Speed Furnaces 398612-YTG-B-0608Johnson Controls Unitary Products PV8*A12 ACCESSORIES TYPICAL INSTALLATIONSOUND POWER RATINGS TYPICAL FIELD WIRINGCOOLING PERFORMANCE DATA CONDENSING UNIT MODEL NOYHJD18S21S1 INDOOR COIL MODEL NOYHJD24S21S1 AHP24COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NOYHJD30S21S1 AHP30COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NOYHJD36S21S1 AHP36COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NOYHJD42S21S1 AHP42COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NOYHJD48S21S1 FC/MC/PC/UC48COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NOYHJD60S21S1 FC/MC62COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NOHEATING PERFORMANCE DATA EVAPORATOR COIL MODEL NOCONDENSING UNIT MODEL NO YHJD18S21S1HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NOYHJD24S21S1 EVAPORATOR COIL MODEL NOHEATING PERFORMANCE DATA CONDENSING UNIT MODEL NOYHJD30S21S1 EVAPORATOR COIL MODEL NOHEATING PERFORMANCE DATA CONDENSING UNIT MODEL NOYHJD36S21S1 EVAPORATOR COIL MODEL NOHEATING PERFORMANCE DATA CONDENSING UNIT MODEL NOYHJD42S21S1 EVAPORATOR COIL MODEL NOAHP/SHP48 HEATING PERFORMANCE DATACONDENSING UNIT MODEL NO YHJD48S21S1HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NOYHJD60S21S1 EVAPORATOR COIL MODEL NOJohnson Controls Unitary Products 5005 York Drive Norman, OK