HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO | YHJD60S21S1 |
|
|
|
|
|
|
| |||
EVAPORATOR COIL MODEL NO | FC/MC62 |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
AIR TEMP. | AIR TEMP. |
|
|
|
|
| ID CFM |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
ENTERING | ENTERING |
|
| 1600 |
|
| 1800 |
|
| 2000 |
|
OUTDOOR UNIT | INDOOR COIL |
|
|
|
|
|
|
|
|
| |
MBTUH |
| KW | C.O.P. | MBTUH | KW | C.O.P. | MBTUH | KW | C.O.P. | ||
|
|
|
|
|
|
|
|
|
|
|
|
| 60 | 75.6 |
| 4.6 | 4.8 | 76.1 | 4.4 | 5.1 | 76.6 | 4.2 | 5.3 |
60 |
|
|
|
|
|
|
|
|
|
|
|
70 | 72.9 |
| 5.1 | 4.2 | 73.4 | 4.9 | 4.4 | 73.8 | 4.6 | 4.7 | |
|
|
|
|
|
|
|
|
|
|
|
|
| 80 | 70.2 |
| 5.6 | 3.7 | 70.6 | 5.3 | 3.9 | 71.0 | 5.1 | 4.1 |
|
|
|
|
|
|
|
|
|
|
|
|
| 60 | 63.8 |
| 4.3 | 4.4 | 64.2 | 4.1 | 4.6 | 64.7 | 3.9 | 4.8 |
47 |
|
|
|
|
|
|
|
|
|
|
|
70 | 61.4 |
| 4.8 | 3.8 | 61.8 | 4.6 | 4.0 | 62.2 | 4.4 | 4.2 | |
|
|
|
|
|
|
|
|
|
|
|
|
| 80 | 59.0 |
| 5.3 | 3.3 | 59.3 | 5.0 | 3.4 | 59.6 | 4.8 | 3.6 |
|
|
|
|
|
|
|
|
|
|
|
|
| 60 | 53.1 |
| 4.0 | 3.9 | 53.2 | 4.2 | 3.7 | 53.3 | 4.3 | 3.6 |
40 |
|
|
|
|
|
|
|
|
|
|
|
70 | 48.9 |
| 4.4 | 3.3 | 49.3 | 4.6 | 3.1 | 49.6 | 4.8 | 3.0 | |
|
|
|
|
|
|
|
|
|
|
|
|
| 80 | 44.7 |
| 4.7 | 2.7 | 45.4 | 5.0 | 2.7 | 46.0 | 5.2 | 2.6 |
|
|
|
|
|
|
|
|
|
|
|
|
| 60 | 47.5 |
| 4.1 | 3.4 | 48.8 | 3.9 | 3.6 | 50.2 | 3.7 | 3.9 |
30 |
|
|
|
|
|
|
|
|
|
|
|
70 | 46.6 |
| 4.5 | 3.0 | 47.3 | 4.4 | 3.2 | 48.1 | 4.2 | 3.4 | |
|
|
|
|
|
|
|
|
|
|
|
|
| 80 | 45.7 |
| 4.9 | 2.7 | 45.8 | 4.8 | 2.8 | 45.9 | 4.6 | 2.9 |
|
|
|
|
|
|
|
|
|
|
|
|
| 60 | 38.3 |
| 3.8 | 2.9 | 40.1 | 3.6 | 3.2 | 41.9 | 3.5 | 3.5 |
17 |
|
|
|
|
|
|
|
|
|
|
|
70 | 36.8 |
| 4.0 | 2.7 | 38.4 | 4.0 | 2.8 | 40.0 | 3.9 | 3.0 | |
|
|
|
|
|
|
|
|
|
|
|
|
| 80 | 35.3 |
| 4.3 | 2.4 | 36.7 | 4.3 | 2.5 | 38.1 | 4.4 | 2.6 |
|
|
|
|
|
|
|
|
|
|
|
|
| 60 | 33.1 |
| 3.4 | 2.9 | 34.5 | 3.5 | 2.9 | 36.0 | 3.6 | 2.9 |
10 |
|
|
|
|
|
|
|
|
|
|
|
70 | 33.2 |
| 3.9 | 2.5 | 34.0 | 3.9 | 2.5 | 34.7 | 3.9 | 2.6 | |
|
|
|
|
|
|
|
|
|
|
|
|
| 80 | 33.4 |
| 4.4 | 2.2 | 33.4 | 4.3 | 2.2 | 33.4 | 4.3 | 2.3 |
|
|
|
|
|
|
|
|
|
|
|
|
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
Air Handler | Coil | MBH | KW | COP |
MV20D | FC/MC62D | 1.00 | 1.01 | 0.99 |
MA20D | FC/MC62D | 1.00 | 1.00 | 1.00 |
Variable Speed | Coil |
| MBH | KW | COP |
Furnace |
| ||||
|
|
|
|
| |
PV8*C20 |
| FC/MC62D | 1.00 | 1.00 | 1.00 |
P(C,V)9*C20 |
| FC/MC62D | 0.98 | 1.00 | 1.00 |
P(C,V)9*D20 |
| FC/MC62D | 0.96 | 1.01 | 0.99 |
Johnson Controls Unitary Products | 29 |