Toshiba RAV-SM562BT-E, RAV-SM1102CT-E, RAV-SM1102BT-E, RAV-SM1403UT-E Super Digital Inverter

Page 12

<Super Digital Inverter>

Model

 

Indoor unit

RAV-

SM562BT-E

SM802BT-E

 

SM1102BT-E

SM1402BT-E

 

 

 

 

 

 

 

 

 

Outdoor unit

RAV-

SP562AT-E

SP802AT-E

 

SP1102AT-E

SP1402AT-E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling capacity

 

 

(kW)

5.0

7.1

 

10.0

12.5

 

 

 

 

 

 

 

 

 

 

Heating capacity

 

 

(kW)

5.6

8.0

 

11.2

14.0

 

 

 

 

 

 

 

 

 

Power supply

 

 

 

 

1 phase 230V (220 – 240V) 50Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Running current

(A)

6.51 – 5.97

9.74 – 8.93

 

11.72 – 10.74

18.09 – 16.58

 

 

 

 

 

 

 

 

 

 

 

 

 

Power consumption

(kW)

1.39

2.10

 

2.50

3.90

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

Power factor

(%)

97

98

 

97

98

 

 

 

 

 

 

 

 

 

 

 

EER

(W/W)

3.60

3.38

 

4.00

3.21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Energy efficiency class *

A

A

 

A

A

 

 

 

 

 

 

 

 

 

 

Electrical

 

 

Energy rating **

 

 

characteristics

 

 

Running current

(A)

7.26 – 6.66

9.74 – 8.93

 

11.72 – 10.74

16.70 – 15.31

 

 

 

 

 

 

 

 

 

 

 

 

 

Power consumption

(kW)

1.55

2.10

 

2.50

3.60

 

 

 

 

 

 

 

 

 

 

 

 

Heating

Power factor

(%)

97

98

 

97

98

 

 

 

 

 

 

 

 

 

 

 

COP

(W/W)

3.61

3.81

 

4.48

3.89

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Energy efficiency class *

A

A

 

A

A

 

 

 

 

 

 

 

 

 

 

 

 

 

Energy rating **

 

 

 

 

 

 

 

 

 

 

 

 

 

Main unit

 

 

 

Zinc hot dipping steel plate

 

 

 

 

 

 

 

 

 

 

 

Appearance

 

Ceiling panel

Model

 

 

 

 

 

 

(Sold separately)

Panel color

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height

(mm)

320

320

 

320

320

 

 

 

 

 

 

 

 

 

 

 

 

Main unit

Width

(mm)

700

1000

 

1350

1350

 

 

 

 

 

 

 

 

 

 

Outer

 

 

Depth

(mm)

800

800

 

800

800

dimension

 

 

Height

(mm)

 

 

 

Ceiling panel

 

 

 

 

 

 

 

 

 

Width

(mm)

 

 

 

(Sold separately)

 

 

 

Depth

(mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total weight

 

Main unit

 

(kg)

30

39

 

54

54

 

 

 

 

 

 

 

 

 

 

Ceiling panel (Sold separately)

(kg)

 

 

 

 

 

 

 

 

 

 

 

 

 

Heat exchanger

 

 

 

 

Finned tube

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan

 

 

Centrifugal

Centrifugal

 

Centrifugal

Centrifugal

 

 

 

 

 

 

 

 

 

 

Fan unit

 

Standard air flow

H/M/L

(m³/min)

13.0/11.9/9.8

19.0/16.2/13.3

 

27.0/23.0/18.9

33.0/28.0/23.1

 

 

 

 

 

 

 

 

 

 

 

 

Motor

 

(W)

120

120

 

120

120

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UFM11BFCE

 

UFM21BFCE

Air filter

 

 

TCB-

UFM21BE

UFM31BE

 

UFM 41BE

 

 

UFM61BE

UFH51BFCE

 

UFH61BFCE

 

 

 

 

 

 

 

 

 

 

 

 

UFM71BE

 

UFH 81BE

 

 

 

 

 

 

 

 

Controller (Sold separately)

 

 

RBC-AMT31E, AS21E2, TCB-SC642TLE2, AX21E2

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas side

(mm)

12.7

15.9

 

15.9

15.9

 

 

 

 

 

 

 

 

 

 

Connecting pipe

 

Liquid side

(mm)

6.4

9.5

 

9.5

9.5

 

 

 

 

 

 

 

 

 

 

 

 

Drain port

(mm)

 

VP25

 

 

 

 

 

 

 

 

 

 

Sound pressure level

H/M/L

(dB•A)

40/37/33

40/37/34

 

42/39/36

44/41/38

 

 

 

 

 

 

 

 

 

Sound power level

H/M/L

(dB•A)

55/52/48

55/52/49

 

57/54/51

59/56/53

 

 

 

 

 

 

 

 

 

 

* : IEC standard, ** : AS standard

– 12 –

Image 12
Contents AIR-CONDITIONER Contents 10-1 10-210-3 10-4Explanation of indications Explanation of illustrated marksConfirmation of warning label on the main unit Indication Explanation∗ For details, refer to the parts list Never recover the refrigerant into the outdoor unitDo not modify the products For spare parts, use those specified ∗Check the following items after reinstallation Metal section Earth positionSide Limit even if the refrigerant leaksSafety Caution Concerned to New Refrigerant Pipe MaterialsCopper pipe Piping Flare nutGeneral tools Conventional tools can be used R410A Conventional airUsed tool Usage Indoor Unit Way Air Discharge Cassette TypeDigital Inverter Super Digital Inverter SP562AT-E SP802AT-EConcealed Duct Type RAV SM562BT-E SM802BT-ESuper Digital Inverter Under Ceiling Type RAV SM562CT-E SM802CT-ERevised Mar Twin Type Indoor unitSP1402AT-E SP1102AT-E RAV SM563AT-E SM803AT-E SP562AT-E SP802AT-E Operation characteristic curve Digital Inverter RAV-SM563AT-E, RAV-SM803AT-ECooling Heating CurrentOperation characteristic curve Super Digital Inverter RAV-SP1102AT-ECapacity variation ratio according to temperature Ratio CapacityOutdoor temp. ˚C Pressure TapHigh Low StaticStatic Pressure Tap Tap LowRAV-SM563UT-E, RAV-SM803UT-E 35˚RAV-SM1103UT-E, RAV-SM1403UT-E, RAV-SP1102UT-E 188Dimension Suction port canvas Separate soldRAV-SM562CT-E, RAV-SM802CT-E, RAV-SM1102CT-E, RAV-SM1402CT-E Space required for service 365 RAV-SP1102AT-E, RAV-SP1402AT-E Indoor unit RAV-SM563UT-E, RAV-SM562BT-E, RAV-SM562CT-E / RAV-SM563AT-EOutdoor unit RAV-SM803UT-E, RAV-SM802BT-E, RAV-SM802CT-E / RAV-SM803AT-E Outdoor unit Distributor TCJ sensorMin. Max 5m 50m Ball valve Packed valve Outer dia. Ø a 25 × L180Outer dia. Ø B Strainer RAV-SM563UT-E, RAV-SM562BT-E, RAV-SM562CT-E / RAV-SP562AT-E TCJRAV-SM803UT-E, RAV-SM802BT-E, RAV-SM802CT-E / RAV-SP802AT-E 1500cc R410A 2.1 kg Cooling HeatingTCJ sensor Distributor Compressor DA420A3F 21M R410A 2.95kg Cooling HeatingL210 FP1.3 flat fin Inside 2500cc RotaryLM1 3 LM2 3Color IdentificationIndoor Unit ColorIdentification LM 3Outdoor Unit Wiring DiagramMCC-5009 BoardBoard MCC-1438MCC-1531 SUB P.C. boardRAV-SP562AT-E, RAV-SP802AT-E BLK Black WHI White BLU Blue BRN Brown Parts name Type Specifications MP24Z2N RAV-SM563AT-E RAV-SM803AT-ECAM-MD12TF-8 TCB-DP22CE2 Drain up kit RBC-U21PG W -E2 Ceiling panelSafety During Installation/Servicing Piping Materials and Joints UsedProcessing of Piping Materials 1 Thicknesses of annealed copper pipes Thickness mmOuter diameter mm R410A R22 12.7 15.9Flare tool for Conventional flare tool R410A clutch type Clutch type Wing nut typeR22 clutch type Clutch type Wing nut type Diameter Width mm43˚to 45˚ 13.0 13.5 12.7 16.2 16.0 12.9 15.9 19.4 19.0 23.3 24.0 19.2Nm kgfm Wrenches available on the marketRequired Tools Refer to the 4. ToolsLow temperature brazing filler Flux Reason why flux is necessaryMaterials for Brazing Silver brazing filler Phosphor bronze brazing fillerCharacteristics required for flux Types of flux Noncorrosive fluxActivated flux Piping materials for brazing and used brazing filler/fluxBasic conditions need to reuse the existing pipe Branching pipe for simultaneous operation systemCuring of pipes Restricted items to use the existing pipesExisting pipe no * Use a new pipes Recovery method of refrigerant for RAV-SM563AT-E, SM803AT-E Work procedureWhen recovering refrigerant in case of reinstalla Main Sub master remote controller Indoor Control CircuitOutline of specifications Remarks Setting at shipment CoolHeating Auto OperationHeat Control temp C Arning Cooling/dry operation In heating/fan operationAll modes Frequency fixed In case of wired remote controller Last push priority CenterOperation Prohibited Normal control Indoor Print Circuit BoardAy Air Concealed Duct Type / Under Ceiling TypeIndoor P.C. Board Optional Connector Specifications Function Connector Pin Specifications RemarksOutdoor Controls AppliedMCC-5009 SM803AT-EP.C board Iewed from partsEEPROM-IC RAV MCC-1531Ipdu MCC-1438 RAV -SP562AT-E, RAVSP1402AT-E RAV -SM1103AT-E, RAV -SM1403AT-EDischarge temperature release control Current release controlOutdoor fan control Operation with WEAllocations of fan tap revolutions rpm TE ˚C TD ˚CCoil heating control Trouble of TE sensorTo ˚C TE ˚CDefrost control Start of heating operationTE ºC ZoneSummary of Troubleshooting Before troubleshootingTroubleshooting procedure Ired remote controller typeTrouble Confirmation of lamp display Check Code List Error mode detected by indoor and outdoor unitsCause of operation Status of air Condition Error mode detected by remote controller Error mode detected by central remote controllerError Mode Detected by LED on Outdoor P.C. Board Type aType B Troubleshooting Procedure for Each Check Code E01 errorE09 error Check CodeE04 error E10 error E18 errorE08, L03, L07, L08 error L09 errorL20 error L30 errorP10 error F10 errorP12 error Only for 4-way air discharge cassette type models CN333CN334 P22 error P19 error F02 errorF01 error P26 errorP29 error H03 errorF06 error F04 errorF08 error L29 error H02 errorP03 error H01 errorP04 error C06 error Central controller Same as others Correct connection of connectorE03 error Master indoor unit F29 error / 12 errorP31 error Sub indoor unit 100101 TA sensor TC, TCJ sensor Caracteristics-2 Caracteristics-1Caracteristics-3 20 TE, TO, TS sensorReplacement Procedure 102R1 Readout of the setup data from Eeprom R2 Replacement of service P.C. boardContents 103R3 Writing of the setup contents to Eeprom Memorandum for setup contents Item code table Example 105Type Item code Indoor unit capacity Item codeTest Run Setup on Remote Controller Wired remote controller106 RAV-SM563UT-E, RAV-SM803UT-E, RAV-SM562BT-E, RAV-SM802BT-EUse either Cool or Heat operation mode for test operation Conditioner from the wireless remote controllerReturn Dip switch of the sensor section as before 107Case of wireless remote controller 108109 Item No. DN table Selection of functionCabling and Setting of Remote Controller Control Indoor unit is controlled by 2 remote controllersSetup method 110Monitor Function of Remote Controller Switch Call of sensor temperature display Contents111 Calling of error history Contents Order to monitor another error history, push112 Group control operationSetup at Local Site / Others TCC-LINK Adapter For TCC-LINK Central Control113 Wiring Specifications C. Board Switch SW01 Setup114 SizeHow to set up central control address number 115Address Setup Address setup procedureItem code Data at shipment Setup data range 116Address Setup & Group Control System configurationOnly turning on source power supply Automatic completion Automatic address example from unset address No miscablingManual setting from remote controller END118 119 No. Part name Procedure Remarks 120Detachment Attachment121 122 CN102 TCJ sensor 2P Red CN333 Power supply of fan motor 123† Fan motor 1. Detachment Remove nuts fixing the fan motor to Remove it124 ‡ Drain pan 1. DetachmentAssembly Perform works of items 1 of , 1 of ‚ Body 1 position, and then remove Assembly. Ø4 × 8, 3 pcsFix the drain pump assembly as before 125Part name Procedure Remarks 126Heat 127 128 129 130 Motor Remove the connector of the fan 131„ Multi blade fan Remove the suction grille Case side. Then fans come off132 133 Heat exchanger support134 Procedure Remarks 135136 137 138 Take off fixed screw for the valve mountingBy hands so that the fan motor does not Fall Tighten the flange nut with torque 4.9Nm 50kgf/cm139 140 Fan guardPerform works of items 1 of , and ‚ With minus screwdriver along with141 ClampRemove the upper cabinet. ST1T Ø4 × 10L, 6 pcs 142 Discharge port cabinet for the heatFin guard Heat exchanger ST1T Ø4 × 10, 2 pcs 143 144 145 146 Motor and the propeller fanLoosen the flange nut by turning clock 147 148 149 Product150 151 ‚ Air-outlet cabinetPut the upper left side of the air-outlet Cabinet on the end plate of heat ex152 „ Inverter Perform the works in 1 of and ƒCN702 PMV Pulse Motor Valve coil Remove connectors and lead wires 153154 155 Case of RAV-SP1102AT-ECase of RAV-SP1402AT-E 156 Pay attention that 4-way valve or PMV is‰ PMV coil 157 158 Reactor Perform works of items to „Electric parts box as shown below so that They do not come to contact with the reac Tor233 231225 209 208 159402 404 401 405 403 160224 212 205 231 161162 224 212 211 225 209 202 226 208 216, 218 205 230229 213, 214, 220 223 207 232 231164 304 311 306 305 301 307 302 303 310 313 308 309 165RBC-U21PG W E2 902 166RAV-SM562BT-E 43196012 Bushing 43166002 Remote Controller 904901, 902, 903 167904 901, 902 168RAV-SM1102BT-E, RAV-SM1402BT-E 402 404 403 406 405401407 169\Location Part Description 44, 45 22, 2336, 37, 38,39, 54 33, 34, 35,53, 56171 404401 407 403 406 402 405 172404 43158193 Reactor 21, 22 14, 16, 17 13, 15, 19 10, 32Muffler 173705 701 702 708 707 706 710 1743332 15, 16 175RAV-SM1103AT-E, RAV-SM1403AT-E 707 708 706 704 703 701 705 702 710 17621,22 16,17 17743146695 Valve, Pulse, Modulating 704 707 178Inverter 26,27 23,24 28,29 179710 706 704 709180 Replacement of Main Parts Sold Separately Drain up Kit181 TCB-DP22CE2Wireless Remote Control Kit 182RBC-AX22CE2 Required parts for installation work Recommendation This is on installation for 2 HP and 3 HP ProductsPart name ’ty Specifications/Vendor Remarks 183Required tools for installation work Part name Specifications Usage184 Cord heater installation wiring diagram 185Cord heater installation work procedure Photo / Explanatory diagram Procedure186 Remove the motor base assembly, partition plate Assembly and the sound insulation board187 Remove the fixing screws of the heat exchanger188 189 Photo / Explanatory diagram Procedure Assembly 190Drawing of thermostat fixing plate Material SGCC-Z08, Thickness 0.8t191 Ø3.4 burring hole Upward Ø3.4 burring hole DownwardBase Plate 192RAV-SM1103AT-E, RAV-SM1403AT-E 193Check of Concentration Limit Toshiba Carrier Corporation
Related manuals
Manual 18 pages 35.13 Kb

RAV-SP1102UT-E, RAV-SM562BT-E, RAV-SM562CT-E, RAV-SM563AT-E, RAV-SM802BT-E specifications

Toshiba, a prominent player in the HVAC sector, has engineered a range of advanced air conditioning systems that cater to diverse environments and needs. Among their standout offerings are the RAV-SM562BT-E, RAV-SM1102CT-E, RAV-SM563AT-E, RAV-SM1403UT-E, and RAV-SM803UT-E models. Each of these systems embodies Toshiba's commitment to energy efficiency, innovative technology, and user-centric design.

The RAV-SM562BT-E model is designed for residential and light commercial use, boasting a cooling capacity of 5.6 kW and a heating capacity of 6.7 kW. It incorporates Toshiba’s advanced inverter technology, ensuring optimal performance and reduced energy consumption. The unit features a sleek, modern design and operates quietly, making it perfect for environments where noise levels must be controlled.

Next in line is the RAV-SM1102CT-E, which excels in larger commercial spaces. With a remarkable cooling output of 11.2 kW and heating performance to match, this unit is engineered for heavy-duty usage. It employs a multi-split system, allowing several indoor units to connect to a single outdoor unit. This provides homes or businesses with flexible installation options without sacrificing comfort or style.

The RAV-SM563AT-E model presents a perfect blend of efficiency and effectiveness, focusing on eco-friendliness. With an impressive seasonal energy efficiency ratio (SEER), it minimizes energy bills while maintaining superior performance. This model is equipped with advanced filtration technology that not only cools or heats the air but also improves indoor air quality by capturing dust and allergens.

Designed for high-performance requirements, the RAV-SM1403UT-E offers cooling and heating capacities of 14.0 kW. This unit is hardy enough for industrial applications but remains efficient and easy to operate. The incorporation of Toshiba’s Smart Control technology allows users to manage their systems remotely, enhancing convenience.

The RAV-SM803UT-E completes the lineup, combining 8.0 kW cooling and heating outputs with cutting-edge technology. It features adaptive comfort control, which adjusts the temperature based on occupancy and external conditions, ensuring optimal comfort while maintaining energy efficiency.

In conclusion, Toshiba's range of RAV-SM series models offers innovative features, advanced technology, and effective performance. These models not only meet the demands of modern spaces but also shine in energy efficiency, making them excellent choices for both residential and commercial applications. By addressing the diverse requirements of users, Toshiba continues to uphold its reputation as a leader in HVAC solutions.