Toshiba RAV-SP560AT-E Electrical Work, SM560AT-E How to remove the valve cover, How to wire

Page 15

6 ELECTRICAL WORK

For the air conditioner that has no power cable, connect a power cable as mentioned below.

 

 

 

SM800AT-E

Model RAV-

SM560AT-E

SP560AT-E

 

 

 

SP800AT-E

 

 

 

Power supply

220 – 240 V

Single phase 50 Hz

 

 

 

 

Maximum running current

12A

 

15A

 

 

 

 

Installation fuse rating

25 A (D type

)

 

 

Power cable

H07 RN-F or 245 IEC 66

(2.5 mm2 or more)

 

 

 

 

CAUTION

Wrong wiring may cause a burnout to some electrical parts.

Be sure to use the cord clamps attached to the product.

Do not damage or scratch the conductive core and inner insulator of power and inter-connecting cables when peeling them.

Be sure to comply with local regulations of the cable from outdoor unit to indoor unit.

(wire size and cabling method etc.)

Use the power and Inter-connecting cables with specified thickness, specified type and protective devices required.

<SM560AT-E>

How to remove the valve cover

1.Remove screws of the valve cover.

2.Pull the valve cover downward to remove it.

Valve cover

Piping cover

Cord clamp

Indoor/outdoor connecting cables

Power cable

How to wire

1.Connect the connecting cable to the terminal as identified with their respective numbers on the terminal block of indoor and outdoor unit.

H07 RN-F or 245 IEC 66 (1.0 mm2 or more)

2.When connecting the connecting cable to the outdoor unit terminal, prevent water coming in the outdoor unit.

3.Insulate the unsheathed cords (conductors) with electrical insulation tape. Process them so that they do not touch any electrical or metal parts.

4.For inter connecting cable, do not use a wire jointed to another on the way.

Use wires long enough to cover the entire length.

Terminal block

1 2 3 L N

Screw

Connecting Power cable cable

Stripping length power cord and connecting cable

L N

10

10

1 2 3

10

 

 

10

40

40

30

30

Earth line

Earth line

(mm)

 

 

Power cable

Connecting

 

 

cable

 

CAUTION

The installation fuse (25A D type ) must be used for the power supply line of this air conditioner.

Incorrect/incomplete wiring might cause an electrical fire or smoke.

Prepare the exclusive power supply for the air conditioner.

This product can be connected to the mains. Connection to the fixed wiring :

A switch which disconnects all poles and has a contact separation of at least 3 mm must be incorporated in the fixed wiring.

47

Image 15
Contents Split Type Adoption of NEW Refrigerant Indoor Unit 4-Way Air Discharge Cassette Type Precautions for Safety New Refrigerant Air Conditioner InstallationTo Disconnect the Appliance from Main Power Supply Accessory and Installation Parts Refrigerant Piping Accessory and RefrigerantBefore installation Selection of InstallationObstacle at front side Upper side is free Installation PlaceNecessary Space for Installation Obstacle at rear side Upper side is freeInstallation of Outdoor Unit Piping connection Optional Installation Parts Local ProcureRefrigerant Piping Connection For ReferenceKnockout procedure How to remove the front panelKnockout of Pipe Cover Projection margin in flaring B Unit mm Flaring Refrigerant PipingPipe Forming/End Positioning Flaring size a Unit mmDo not apply refrigerating machine oil to the flared surface Tightening of Connecting PartEvacuating Air PurgeVacuum pump Evacuating How to open the valveElectrical Work SM560AT-E How to remove the valve coverHow to wire Stripping length power cord and connecting cableFinal Installation Checks Check and Test OperationSelf-Diagnosis by LED Indication New tools for R410A Changes in the product and componentsPrecautions for Safety Accessory and Installation Parts SP1100AT-E, SP1400AT-E only SP1100AT-E, SP1400AT-ELength of refrigerant pipe SM1100AT-E, SM1400AT-E Single unitIn installation Moreor Liquid side Gas side Outer diameter Thickness Ø9.5 Ø15.9 Rigid Clutch type Projection margin in flaring B Unit mmValve at gas side Evacuating How to open the valve Model RAV SM1400AT-E Useful Functions Final Installation Checks

RAV-SP1100UT-E, RAV-SP800AT-E, RAV-SP1100AT-E, RAV-SP1400UT-E, RAV-SP560AT-E specifications

Toshiba has consistently been at the forefront of advancing air conditioning technologies, and its line of products, including the RAV-SP1100AT-E, RAV-SP1100UT-E, RAV-SP1400UT-E, RAV-SP800AT-E, and RAV-SP560AT-E, exemplifies this commitment to quality and innovation. These models reflect Toshiba’s dedication to energy efficiency, user comfort, and technological sophistication.

The RAV-SP1100AT-E and RAV-SP1100UT-E are notable for their robust cooling capacities, making them ideal for medium to large spaces. With energy efficiency ratings that comply with global standards, these units help reduce electricity costs while maintaining optimal indoor temperatures. Both models feature advanced inverter technology, which allows for precise cooling and heating control. This technology not only ensures energy savings but also supports quieter operation, enhancing the overall comfort of the environment.

The RAV-SP1400UT-E stands out for its high-performance capabilities, designed to provide efficient climate control even under extreme conditions. This model integrates cutting-edge refrigerant technology, which minimizes environmental impact without compromising on performance. The RAV-SP1400UT-E offers advanced air purification systems that help eliminate dust and allergens, contributing to improved indoor air quality.

For those seeking compact yet powerful solutions, the RAV-SP800AT-E and RAV-SP560AT-E models are excellent choices. They are designed for smaller spaces without sacrificing efficiency. These units are equipped with compact designs that make installation straightforward, while still incorporating Toshiba’s inverter technology, allowing for both heating and cooling functions that adapt seamlessly to changing weather patterns.

All these models support advanced connectivity options, enabling users to monitor and control their units remotely through smart devices. This feature adds convenience and flexibility, allowing for greater energy management and comfort personalization.

In conclusion, Toshiba’s RAV-SP series embodies a blend of energy efficiency, advanced technology, and user-friendly features. These models not only cater to various cooling and heating needs but also prioritize environmental responsibility. With their ability to provide reliable performance across a range of conditions, Toshiba’s RAV-SP1100AT-E, RAV-SP1100UT-E, RAV-SP1400UT-E, RAV-SP800AT-E, and RAV-SP560AT-E stand out as exemplary choices for residential and commercial climate control solutions.