York H*RD036 THRU 060, H*RD018 THRU 060 Accessories, Sound Power Ratings, Typical Installation

Page 16

254892-YTG-C-0606

ACCESSORIES

Refer to Price Manual for specific model numbers.

HARD START KIT - Provides increased starting torque for areas with low voltage.

COMPRESSOR BLANKET - Designed to further reduce the normal compressor operating sound. Refer to price pages for specific match-ups.

OFF CYCLE TIMER DELAY - Provides a 5-minute off cycle to prevent rapid recycling of the compressor.

ROOM THERMOSTATS - A wide selection of compatible thermosets are available to provide optimum performance and features for any installation.

1H/1C, manual change-over electronic non-programmable thermostat.

1H/1C, auto/manual changeover, electronic programmable, deluxe 7-day, thermostat.

1H/1C, auto/manual changeover, electronic programmable.

*For the most current accessory information, refer to the price book or consult factory.

SOUND POWER RATINGS*

UNIT MODEL

(dBA)

018

75

024

74

030

75

036

75

042

76

048

76

060

76

* Rated in accordance with ARI 270-95 Standards.

TYPICAL INSTALLATION

 

MINIMUM 24” SERVICE ACCESS

THERMOSTAT

TO FURNACE OR

60” OVERHEAD

CLEARANCE ON ONE SIDE

 

 

AIR HANDLER

CLEARANCE

WEATHERPROOF

 

 

TERMINAL BLOCK

 

DISCONNECT

 

 

 

 

 

SWITCH

 

NEC CLASS 1 WIRING

 

 

 

NEC CLASS 2 WIRING

10” CLEARANCE

 

 

TO INDOOR COIL

COIL AREA

 

 

NOTE: ALL OUTDOOR WIRING MUST BE WEATHERPROOF.

SEAL OPENING(S) WITH

PERMAGUM OR EQUIVALENT

CONTROL ACCESS PANEL

TYPICAL FIELD WIRING - 1 Phase Application

ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES

POWER WIRING

208/230-1-60

POWER WIRING

24 VOLT CONTROL WIRING

 

CONTROL WIRING

MINIMUM 18 GA. WIRE

 

 

 

 

FACTORY WIRING

(NEC CLASS 2)

 

 

 

 

 

 

FURNACE OR AIR HANDLER TERMINAL BLOCK

CONTACTOR

TERMINALS

GND.

LUGCOIL

CONDENSING UNIT

C Y R G W

* TERMINAL W IS ONLY REQUIRED ON SYSTEMS WITH HEAT.

*

Y R G W

ROOM THERMOSTAT

ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY.

16

Unitary Products Group

Image 16
Contents Features WarrantyDescription Physical and Electrical Data 1 Phase DimensionsModel UnitIndoor Coil1,2 TXV KIT3 Additional Charge, Oz HC18A3X HC30A3XHC36B3X HC42C3X HC60C3X HD24A3X HD36B3X HD48C3X HD60D3X AHP18B3X AHP24B3XProcedures FootnotesPhysical and Electrical Data 3 Phase H1RDIndoor Coil1 Additional Charge, Oz Footnotes PH 13 Seer AC with MV Variable Speed PH 13 Seer AC with AV / SV Variable Speed SensSeer AC with AHP / F*FP / F*FV Cooling Unit Model CFM Range Rated NET MBH SEER1 FurnaceTotal Sens FC/MC/PC/UC48 FC/MC/PC/UC42FC/MC/PC/UC60 FC/MC/PC18A FC/MC/PC18BFC/MC/PC24A FC/MC/PC24BFC/MC/PC42B FC/MC/PC42CFC/MC/PC48C FC/MC/PC48DFC/PC60C Sens PH 13 Seer AC with Variable Speed FURNACES2FC/MC/PC60D Sound Power Ratings AccessoriesTypical Installation Temperature Cooling Performance DataAIR Conditioner Model no Indoor Coil Model no FC/MC/PC/UC18 CondensingH2RD024S06 Indoor Coil Model no FC/MC/PC/UC24 CondensingH2RD030S06 , H1RD030S25,46 Indoor Coil Model no FC/MC/PC/UC30 CondensingMA12B MC30B MC36B AHP30 AHP36Indoor Coil Model no FC/MC/PC/UC36 Condensing H2RD036S06 , H1RD036S25,46AHP36 AHP42 AHP/SHP60 H2RD042S06 , H1RD042S25,46 Indoor Coil Model no FC/MC/PC/UC42 CondensingMA12C MC42C MA14D MC42D MC48C MC48D MA12CIndoor Coil Model no FC/MC/PC/UC48 Condensing H2RD048S06, H1RD048S25,46MA12C MC48C MA20D MC48D H2RD060S06, H1RD060S25,46 Indoor Coil Model no FC/MC/PC/UC60 CondensingMA20D MC60D MC61D MA20D MC60DUnitary 5005 Norman Products York Group Drive 73069