HP dc5850 manual Memory Error Messages, Table A-4, Message Probable Cause

Page 98

Error Messages and Codes

A.5 Memory Error Messages (2xx-xx)

 

Table A-4.

 

Memory Error Messages

 

 

Message

Probable Cause

 

 

200-04

Real memory size changed

 

 

200-05

Extended memory size changed

 

 

200-06

Invalid memory configuration

 

 

200-07

Extended memory size changed

 

 

200-08

CLIM memory size changed

 

 

201-01

Memory machine ID test failed

 

 

202-01

Memory system ROM checksum failed

 

 

202-02

Failed RAM/ROM map test

 

 

202-03

Failed RAM/ROM protect test

 

 

203-01

Memory read/write test failed

 

 

203-02

Error while saving block in read/write test

 

 

203-03

Error while restoring block in read/write test

 

 

204-01

Memory address test failed

 

 

204-02

Error while saving block in address test

 

 

204-03

Error while restoring block in address test

 

 

204-04

A20 address test failed

 

 

204-05

Page hit address test failed

 

 

205-01

Walking I/O test failed

 

 

205-02

Error while saving block in walking I/O test

 

 

205-03

Error while restoring block in walking I/O test

 

 

206-xx

Increment pattern test failed

 

 

207-xx

ECC failure

 

 

210-01

Memory increment pattern test

 

 

210-02

Error while saving memory during increment pattern test

 

 

210-03

Error while restoring memory during increment pattern test

 

 

211-01

Memory random pattern test

 

 

 

A-6

www.hp.com

Technical Reference Guide

Image 98
Contents Technical Reference Guide OctoberTechnical Reference Guide Contents System Support Input/Output InterfacesPower and Signal Distribution Integrated Graphics SubsystemSystem Bios Error Messages and Codes IndexAdditional Information Sources IntroductionAbout this Guide Online ViewingSpecial Notices Serial NumberNotational Conventions ValuesAcronym or Abbreviation Description Common Acronyms and AbbreviationsAcronyms and Abbreviations CDS Eisa LAN PAL Sdvo URL Introduction System Overview IntroductionFeatures Feature Difference Matrix by Form Factor SFFSystem Architecture HP Compaq dc5850 Business PC Architecture, Block diagram Chipset Components and Functionality AMD Processor SupportChipset Components FunctionSupport Component Functions Support ComponentsSystem Memory Component Name FunctionUniversal Serial Bus Interface Mass StorageSerial Interface Network Interface ControllerIntegrated Graphics Subsystem Statistics Integrated Graphics ProcessorAudio Subsystem Integrated Graphics ControllerPower Supply Electrical Specifications SpecificationsEnvironmental Specifications Factory Configuration Parameter Operating Non-operatingPhysical Specifications Parameter SFFSystem Overview Processor/Memory Subsystem Processor/Memory Subsystem ArchitectureProcessor Changing/Upgrading AMD ProcessorsAMD Processor Overview Supported Processors partial listingMemory Subsystem Memory Socket Loading Memory Loading/UpgradingMemory Mapping and Pre-allocation Channel a Channel B SocketSystem Memory Map for maximum of 8 gigabytes Processor/Memory Subsystem PCI 2.3 Bus Operation System SupportPCI Bus Overview Software/Driver Layer Device REQ/GNT Line PCI Connector SlotPCI Express Bus Operation Transaction Protocol LayerPCI Interrupts PCI Power Management SupportOption ROM Mapping Link LayerPCI 2.3 Bus Connector Pinout PCI ConnectorsPCI 2.3 Connector PCI Express Connectors PCI Express Bus Connector PinoutInterrupts Apic ModeSystem Resources ModePCI Interrupt Distribution Direct Memory AccessConnector PCI slot 1 J20 System Interrupts System BoardReal-Time Clock and Configuration Memory Clearing CmosStandard Cmos Locations Configuration Memory Cmos MapSystem Management Security FunctionsInterface Security Power-On / Setup PasswordCable Lock Provision Acpi Wake-Up Event System Wakes From Power ManagementAcpi Wake-Up Events Thermal Sensing and Cooling System Status PowerLED Beeps Action RequiredSystem Status System Operational Status LED IndicationsRegister Map and Miscellaneous Functions System I/O MapSystem I/O Map Port FunctionSIO Controller Functions Gpio FunctionsSB700 Functions System Support Input/Output Interfaces Sata Interfaces Sata ConnectorPin Sata Connector Pinout AHCI/RAID SupportRAID 1-Mirroring with Two Hard Drives Factory Configuration for RAIDImplementing Ahci RAID for Non-Factory Configurations Diskette Drive Interface Pin Diskette Drive Connector Pinout Pin Signal DescriptionDB-9 Serial Connector Pinout Serial InterfaceExtended Capabilities Port Mode Standard Parallel Port ModeEnhanced Parallel Port Mode Parallel Interface SupportPin Signal Function Parallel Interface ConnectorDB-25 Parallel Connector Pinout Keyboard/Pointing Device Interface Keyboard Interface OperationPointing Device Interface Operation Keyboard/Pointing Device Interface ConnectorKeyboard/Pointing Device Connector Pinout SB700 signals USB Connector Location USB ConnectorUSB Connector Pinout Universal Serial Bus InterfaceUSB Cable Length Data Signal Insulation colorUSB Cable Data USB Color CodeAudio Subsystem Functional Block Diagram Audio SubsystemAudio Multistreaming HD Audio ControllerHD Audio Link Bus Parameter Measurement Audio SpecificationsHD Audio Subsystem Specifications Network Interface Controller LAN I/F NICAlert Standard Format Support Power Management SupportWake-On-LAN Support NIC Specifications NIC ConnectorNIC Specifications Parameter Compatibility standard orprotocolIntegrated Graphics Processor Integrated Graphics Processor, Block diagram Functional DescriptionUpgrading DB-15 Monitor Connector Pinout Monitor ConnectorsAnalog Monitor Connector Pin Signal DVI-D ConnectorDVI-D Monitor Connector Pinout Integrated Graphics Processor Power and Signal Distribution Power DistributionMin Range Current Max Surge Tolerance Loading Ripple SFF Power SupplySFF 240-Watt Power Supply Unit Specifications Range or Min Current Max Surge Tolerance Loading Ripple MT Power SupplyMT 300-Watt Power Supply Unit Specifications Power Button Actions Power ControlPower Button Pressed Power Button ResultsPower LED Indications Condition Wake Up Events Wake-On-LANState System Condition System Power StatesPower Transition OS Restart Consumption To S0 by RequiredDesignator Component function Signal DistributionSystem Board Component Designations Shows pinouts of headers used on the sytem boards Power and Signal Distribution System Bios Changeable Splash Screen ROM FlashingUpgrading Network Boot F12 Support Boot FunctionsBoot Device Order Memory Detection and ConfigurationVisual power LED Audible speaker Meaning Boot Error CodesBoot Error Codes Client Management Functions INT15 Function ModeClient Management Functions System ID Numbers Temperature StatusSystem ID and ROM Type System System ID Form Factor Subsystem Device IDSmbios Functions Type DataUSB Legacy Support Management FunctionsTable A-1 Beep/Power LED Codes Error Messages and CodesBeep/Power LED Codes Beeps Power LED Probable CausePower-On Self Test Post Messages Table A-2 Error Messages and Codes System Error Messages Table A-3 System Error Messages Probable CauseTable A-4 Memory Error MessagesMemory Error Messages Message Probable CauseKeyboard Error Messages Table A-5 Keyboard Error Messages Probable CauseTable A-6 Printer Error Messages Probable Cause Printer Error MessagesVideo Graphics Error Messages Table A-7 Video Graphics Error Messages Probable CauseDiskette Drive Error Messages Table A-8 Diskette Drive Error Messages Probable CauseSerial Interface Error Messages Table A-9 Serial Interface Error Messages Probable CauseModem Communications Error Messages Table A-11 System Status Error MessagesSystem Status Error Messages Hard Drive Error Messages Table A-12 Hard Drive Error Messages Probable CauseXx = 03, Hard drive read/write compare test Table A-13 Hard Drive Error Messages Probable Cause Table A-15 Audio Error Messages Probable Cause Audio Error MessagesTable A-14 Video Graphics Error Messages Probable Cause DVD/CD-ROM Error Messages 17 DVD/CD-ROM Error MessagesNetwork Interface Error Messages Table A-17 Network Interface Error Messages Probable CauseScsi Interface Error Messages 65xx-xx, 66xx-xx Table A-18 Scsi Interface Error MessagesPointing Device Interface Error Messages 8601-xx Error Messages and Codes Index NumericsIndex
Related manuals
Manual 4 pages 1.09 Kb Manual 19 pages 40.13 Kb Manual 69 pages 369 b

dc5850 specifications

The HP dc5850 is a desktop computer that was designed for business environments, offering a blend of performance, reliability, and efficiency. Released during the height of the mid-2000s, this system is powered by AMD processors, particularly the Athlon or Phenom series, which ensures that it can handle various computational tasks with ease.

The dc5850 features a compact chassis that adheres to the Microtower form factor. This design not only saves space but also allows for easier upgrades and maintenance. The unit typically supports a range of RAM configurations, with options for up to 8GB of DDR2 memory. This flexibility enables the user to tailor the system's performance according to their needs, whether for basic office tasks or more demanding applications.

Storage options on the HP dc5850 include a 3.5-inch HDD that can accommodate substantial data, with capacities typically ranging from 160GB to 1TB. The inclusion of a SATA interface ensures fast data transfer rates, which is essential for improving overall system performance. Moreover, the dc5850 boasts multiple USB ports, including USB 2.0 and sometimes even USB 3.0, facilitating easy connectivity with peripherals such as printers, scanners, and external drives.

Graphics capabilities on the dc5850 are generally provided by integrated solutions, although users have the option to add discrete graphics cards for enhanced performance in visual tasks. The system often comes with integrated audio, which supports basic multimedia needs without requiring additional sound cards.

In terms of connectivity, the HP dc5850 features built-in Ethernet for wired networking and may also offer options for Wi-Fi capabilities via PCI expansion slots. This makes it suitable for networked business environments, enabling seamless integration into office infrastructures.

The system is designed with energy efficiency in mind, complying with various environmental standards, thereby reducing its carbon footprint. This aspect may also lead to lower operational costs for businesses focused on sustainability.

Overall, the HP dc5850 stands out as a versatile desktop solution, catering to the essential needs of small to medium-sized businesses. With its combination of performance, expandability, and energy efficiency, it remains a noteworthy choice for users seeking reliable computing power in a compact and manageable form.