York R-410A manual Guide Specifications, Field Installed Acessories Fresh Air

Page 10

528194-YTG-F-1210

Accessories (Continued)

Field Installed Acessories - Fresh Air

MODEL

VOLTAGE

DESCRIPTION

WHERE USED

 

All

Barometric Relief Kit for Power Exhaust, Downflow

 

1EH0407

Application (Includes Hood)

All Cabinets

 

 

 

Barometric Relief Kit for Power Exhaust, Horizontal

 

1EH0408

All

Application

All Cabinets

 

 

Barometric Relief/Hood Kit - Required for field installed

 

1EH0409

All

slab economizer without ERV

All Cabinets

1FA0413

All

Manual Outside Air Damper 0-35%, Downflow

All Cabinets

1FA0414

All

Manual Outside Air Damper 0-100%, Downflow

All Cabinets

1RD0411

All

Barometric Relief Kit for Horizontal Applications

All Cabinets

2EC04700924

All

Dual Enthalpy Control

All Cabinets

 

 

Downflow Economizer, Slab type for ERV, (no

 

2EE04705724

All

Barometric Relief or FA hood)

All 50" Cabinets

 

 

Downflow Economizer, Slab type for ERV, (no

 

2EE04705824

All

Barometric Relief or FA hood)

All 42" Cabinets

2EE04705924

All

Downflow Economizer with Barometric Relief

All Cabinets

2EE04706024

All

Horizontal Economizer without Barometric Relief

All Cabinets

2MD04703224

All

Motorized Damper, Downflow without Barometric Relief

All Cabinets

2MD04703724

All

Motorized Damper, Horizontal

All Cabinets

2PE04703225*

230

Power Exhaust 230V Downflow or Horizontal

All Cabinets

2PE04703246*

460

Power Exhaust 460V Downflow or Horizontal

All Cabinets

2PE04703258*

575

Power Exhaust 575V Downflow or Horizontal

All Cabinets

* Must be installed in return Duct on Horizontal Applications and a 1EH0408 is required.

Field Installed Acessories - Controls

MODEL

VOLTAGE

DESCRIPTION

WHERE USED

2AP0401

All

Air Proving Switch

All Units

2AQ04700324

All

CO2 Space Accessory

All Units

2AQ04700424

All

CO2 Unit Accessory

All Units

2DF0402

All

Dirty Air Switch

All Units

2DH04700024

All

Humidistat

All Units

 

 

 

All Gen 4 or older units with 2" Filter only capable

2SD04700624

All

Smoke Detector for Supply or Return

Cabinets

2SD04700824

All

Smoke Detector for Supply

All Gen 5 units with 2" & 4" Filters

2SD04700924

All

Smoke Detector for Return

All Gen 5 units with 2" & 4" Filters

2SD04701024

All

Smoke Detector for Supply and Return

All Gen 5 units with 2" & 4" Filters

Field Installed Acessories - Electrical

MODEL

VOLTAGE

DESCRIPTION

WHERE USED

2BC04700106

230

Gas heat kit, -60ºF

All Units

2BC04700151

460

Gas heat kit, -60ºF

All Units

2BC04700154

575

Gas heat kit, -60ºF

All Units

2LA04704632

All

Low Ambient Kit

All 3 - 10T units (excludes 12.5T "V" cabinets)

Guide Specifications

GENERAL

Units shall be manufactured by York International Unitary Products in an ISO 9001 certified facility. YORK® Predator® units are convertible single packages with a common footprint cabinet and common roof curb for all 6-1/2 through 12-1/2 ton models. All units have two compressors with independent R- 410A refrigeration circuits to provide 2 stages of cooling. The units were designed for light commercial applications and can be easily installed on a roof curb, slab, or frame. All Predator® units are self-contained and assembled on rigid full perimeter base rails allowing for 3-way forklift access and overhead rigging. Every unit is completely charged with R-410A, wired, piped, and tested at the factory to provide a quick and easy field installation. All units are convertible between side and down airflow. Independent economizer designs are used on side and down discharge applications, as well as all tonnage

sizes. Predator® units are available in the following configurations: cooling only, cooling with electric heat, cooling with gas heat, heat pump, and heat pump with electric heat. Electric heaters are available as factory-installed options or field-installed accessories.

DESCRIPTION

Units shall be factory assembled, single package, (Elec/Elec, Gas/ Elec), designed for outdoor installation. They shall have built in field convertible duct connections for down discharge supply/return or horizontal discharge supply/return and be available with factory installed options or field installed accessories. The units shall be factory wired, piped and charged with R-410A refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. The cooling performance shall be rated in accordance with DOE and ARI test procedures. Units shall be CSA certified to ANSI Z21.47 and UL 1995/CAN/CSA No. 236- M90 standards.

10

Johnson Controls Unitary Products

Image 10
Contents Technical Guide R-410A ZF Series DescriptionTable of Contents Component LocationNomenclature Ton York Model Number NomenclatureFeatures and Benefits Standard FeaturesFactory Installed Options YTG-F-1210 Field Installed Accessories Control OptionsYTG-F-1210 Field Installed Acessories Electric Heat AccessoriesField Installed Acessories Non-Electrical Description Where UsedField Installed Acessories Controls Guide SpecificationsField Installed Acessories Fresh Air Field Installed Acessories ElectricalUnit Cabinet GAS Heating Section if Equipped Other PRE-ENGINEERED Accessories Available Physical Data ZF078-150 Physical DataBelt Drive Evap FAN Data ZF078 ZF090 ZF102 ZF120 ZF150Condenser FAN Data FiltersUnit Voltage Applied Voltage ZF078-150 Unit LimitationsSize Unit Limitations MinZF078-150 Cooling Capacities Capacity PerformanceZF078 6.5 Ton 115F ZF090 7.5 Ton ZF090 7.5 Ton ZF102 8.5 Ton ZF102 8.5 Ton ZF120 10 Ton ZF120 10 Ton ZF150 12.5 Ton 115F 125F ZF078 6.5 Ton Side Duct Airflow PerformanceZF078-150 Side Duct Application ZF090 7.5 Ton Side DuctZF150 12.5 Ton Side Duct ZF120 10 Ton Side DuctAvailable External Static Pressure IWG1 ZF090 7.5 Ton Bottom Duct ZF078-150 Bottom Duct ApplicationZF078 6.5 Ton Bottom Duct ZF102 8.5 Ton Bottom DuctZF120 10 Ton Bottom Duct ZF150 12.5 Ton Bottom DuctAdditional Static Resistance RPM SelectionCFM Airflow Performance Factor Altitude/Temperature Correction FactorsAir Temperature ºF CorrectionGas Heat Minimum Supply Air Indoor Blower SpecificationsPower Exhaust Specifications Electric Heat Minimum Supply AirSound Performance Indoor Sound Power LevelsOutdoor Sound Power Levels ZF078-150 Electric Heat MultipliersZF078-150 Standard Motor Without Powered Convenience Outlet Electrical DataZF078-150 Standard Motor Without Powered Convenience Outlet ZF078-150 Hi Static Motor Without Powered Convenience Outlet ZF078-150 Hi Static Motor Without Powered Convenience Outlet ZF078-150 Standard Motor With Powered Convenience Outlet ZF078-150 Standard Motor With Powered Convenience Outlet ZF078-150 Hi Static Motor With Powered Convenience Outlet ZF078-150 Hi Static Motor With Powered Convenience Outlet Typical Wiring Diagrams ZF078-150 Typical Wiring DiagramsYTG-F-1210 YTG-F-1210 YTG-F-1210 YTG-F-1210 YTG-F-1210 Typical ZF078-150 Factory Installed VFD Option YTG-F-1210 YTG-F-1210 YTG-F-1210 YTG-F-1210 YTG-F-1210 Typical ZF078-150 VFD Ready Unit Option ZF078-150 Unit Weights Weights and DimensionsUnit 4 Point Load Weight Unit 6 Point Load Weight ZF078 ZF078-150 Unit DimensionsZF078-150 Unit Accessory Weights Shipping OperatingDimension ZF078-150 Unit Physical DimensionsZF150 Detail a Detail BZF078-150 Unit Clearances TOP View ZF078-150 Unit Bottom Duct OpeninFront ZF150 Unit Side Duct Openings ZF Side Duct DimensionsZF078-150 Unit Left Duct Opening ZF078-150 Roof Curb ZF078-150 Unit Accessory DimensionsZF078-150 Transition Roof Curb ZF078-150 Economizer Assembly Economizer Options Factory Installed Downflow EconomizerField Installed Downflow Economizer W/Power Exhaust Economizer UsageField Installed Horizontal Economizer W/Power Exhaust Slab Economizer Downflow W/Power ExhaustSlab Economizer End Return W/Power Exhaust Johnson Controls Unitary Products York Drive Norman, OK
Related manuals
Manual 24 pages 22.74 Kb Manual 104 pages 7.39 Kb Manual 128 pages 30.42 Kb Manual 36 pages 24.83 Kb

R-410A specifications

York R-410A is a widely recognized and highly efficient refrigerant used in modern air conditioning systems. Developed as an environmentally friendly alternative to R-22, R-410A has gained popularity in the HVAC industry due to its numerous advantageous features and characteristics.

One of the main features of York R-410A is its ability to provide superior cooling performance. This refrigerant operates efficiently at both high and low temperatures, allowing systems using it to maintain optimal indoor climates even during extreme weather conditions. Its high energy efficiency ratio (EER) and seasonal energy efficiency ratio (SEER) ratings make it a preferred choice for energy-conscious consumers, resulting in lower energy bills and a reduced carbon footprint.

Technologically, York R-410A systems feature advanced compressor designs that enhance their overall reliability and performance. These compressors are often equipped with variable-speed technology, enabling them to adjust their output to match the cooling demands of the space. This not only improves comfort levels but also leads to efficient energy consumption, reducing wear and tear on the equipment over time.

Another significant characteristic of York R-410A is its non-ozone-depleting properties. Unlike its predecessor R-22, which is being phased out due to its damaging effects on the ozone layer, R-410A is designed to minimize environmental impact. Its lower global warming potential (GWP) further underscores its role in promoting sustainability within the HVAC sector.

Furthermore, York R-410A systems are engineered with enhanced safety features. The refrigerant is non-toxic and non-flammable, which makes it safer for use in both residential and commercial applications. Additionally, its high thermal stability reduces the risk of breakdown or leakage, contributing to longer system lifespans and lower maintenance costs.

In conclusion, York R-410A stands out as a cutting-edge refrigerant that combines efficiency, safety, and environmental responsibility. With its advanced technologies and remarkable characteristics, it meets the demands of modern air conditioning requirements while paving the way for a sustainable future in HVAC systems. Adopting York R-410A not only benefits individual users through improved comfort and lower energy bills but also plays a vital role in protecting our planet's ozone layer and mitigating climate change.