York R-410A manual YTG-F-1210

Page 47

528194-YTG-F-1210

Typical ZF150 Cooling Unit with Gas Heat 230 Volt Wiring Diagram

Johnson Controls Unitary Products

47

Image 47
Contents Description Technical Guide R-410A ZF SeriesComponent Location Table of ContentsTon York Model Number Nomenclature NomenclatureStandard Features Features and BenefitsFactory Installed Options YTG-F-1210 Control Options Field Installed AccessoriesYTG-F-1210 Description Where Used AccessoriesField Installed Acessories Non-Electrical Field Installed Acessories Electric HeatField Installed Acessories Electrical Guide SpecificationsField Installed Acessories Fresh Air Field Installed Acessories ControlsUnit Cabinet GAS Heating Section if Equipped Other PRE-ENGINEERED Accessories Available ZF078-150 Physical Data Physical DataFilters ZF078 ZF090 ZF102 ZF120 ZF150Condenser FAN Data Belt Drive Evap FAN DataMin ZF078-150 Unit LimitationsSize Unit Limitations Unit Voltage Applied VoltageZF078 6.5 Ton Capacity PerformanceZF078-150 Cooling Capacities 115F ZF090 7.5 Ton ZF090 7.5 Ton ZF102 8.5 Ton ZF102 8.5 Ton ZF120 10 Ton ZF120 10 Ton ZF150 12.5 Ton 115F 125F ZF090 7.5 Ton Side Duct Airflow PerformanceZF078-150 Side Duct Application ZF078 6.5 Ton Side DuctAvailable External Static Pressure IWG1 ZF120 10 Ton Side DuctZF150 12.5 Ton Side Duct ZF102 8.5 Ton Bottom Duct ZF078-150 Bottom Duct ApplicationZF078 6.5 Ton Bottom Duct ZF090 7.5 Ton Bottom DuctZF150 12.5 Ton Bottom Duct ZF120 10 Ton Bottom DuctCFM RPM SelectionAdditional Static Resistance Airflow Performance Correction Altitude/Temperature Correction FactorsAir Temperature ºF FactorElectric Heat Minimum Supply Air Indoor Blower SpecificationsPower Exhaust Specifications Gas Heat Minimum Supply AirElectric Heat Multipliers Indoor Sound Power LevelsOutdoor Sound Power Levels ZF078-150 Sound PerformanceElectrical Data ZF078-150 Standard Motor Without Powered Convenience OutletZF078-150 Standard Motor Without Powered Convenience Outlet ZF078-150 Hi Static Motor Without Powered Convenience Outlet ZF078-150 Hi Static Motor Without Powered Convenience Outlet ZF078-150 Standard Motor With Powered Convenience Outlet ZF078-150 Standard Motor With Powered Convenience Outlet ZF078-150 Hi Static Motor With Powered Convenience Outlet ZF078-150 Hi Static Motor With Powered Convenience Outlet ZF078-150 Typical Wiring Diagrams Typical Wiring DiagramsYTG-F-1210 YTG-F-1210 YTG-F-1210 YTG-F-1210 YTG-F-1210 Typical ZF078-150 Factory Installed VFD Option YTG-F-1210 YTG-F-1210 YTG-F-1210 YTG-F-1210 YTG-F-1210 Typical ZF078-150 VFD Ready Unit Option Unit 4 Point Load Weight Unit 6 Point Load Weight Weights and DimensionsZF078-150 Unit Weights Shipping Operating ZF078-150 Unit DimensionsZF078-150 Unit Accessory Weights ZF078ZF150 ZF078-150 Unit Physical DimensionsDimension ZF078-150 Unit Clearances Detail BDetail a ZF078-150 Unit Bottom Duct Openin TOP ViewFront ZF078-150 Unit Left Duct Opening ZF Side Duct DimensionsZF150 Unit Side Duct Openings ZF078-150 Transition Roof Curb ZF078-150 Unit Accessory DimensionsZF078-150 Roof Curb ZF078-150 Economizer Assembly Economizer Usage Factory Installed Downflow EconomizerField Installed Downflow Economizer W/Power Exhaust Economizer OptionsSlab Economizer Downflow W/Power Exhaust Field Installed Horizontal Economizer W/Power ExhaustJohnson Controls Unitary Products York Drive Norman, OK Slab Economizer End Return W/Power Exhaust
Related manuals
Manual 24 pages 22.74 Kb Manual 104 pages 7.39 Kb Manual 128 pages 30.42 Kb Manual 36 pages 24.83 Kb