York R-410A manual ZJ300 25 Ton Side Duct

Page 51

251934-YTG-G-0708

ZJ300 (25 Ton) Side Duct

Air Flow

 

 

 

 

Available External Static Pressure - IWG1

 

 

 

 

0.4

0.6

0.8

 

1.0

 

1.2

1.4

1.6

1.8

(CFM)

 

 

RPM BHP

RPM BHP

RPM BHP

 

RPM BHP

 

RPM BHP

RPM BHP

RPM BHP

RPM BHP

 

Low Static

7.5 HP &

 

 

 

 

 

 

Low Static 7.5 HP & Drive

 

 

 

 

 

Field Supplied Drive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6600

760

2.51

793

3.11

824

3.68

 

856

4.23

 

887

4.74

919

5.23

950

5.70

983

6.15

7000

775

2.99

808

3.60

839

4.17

 

871

4.71

 

902

5.22

934

5.72

966

6.19

998

6.64

7400

792

3.51

824

4.11

856

4.69

 

887

5.23

 

918

5.74

950

6.24

982

6.70

1014

7.16

7800

809

4.07

841

4.67

873

5.24

 

904

5.78

 

935

6.30

967

6.79

999

7.26

1031

7.71

8200

826

4.66

859

5.27

890

5.84

 

922

6.38

 

953

6.89

985

7.39

1016

7.86

1049

8.31

8600

845

5.30

877

5.90

909

6.47

 

940

7.01

 

972

7.53

1003

8.02

1035

8.49

1067

8.94

9000

864

5.97

896

6.57

928

7.14

 

960

7.69

 

991

8.20

1022

8.69

1054

9.16

1087

9.61

9400

884

6.68

916

7.28

948

7.86

 

980

8.40

 

1011

8.91

1042

9.41

1074

9.88

1107 10.33

9800

905

7.43

937

8.04

969

8.61

 

1000

9.15

 

1032

9.67

1063 10.16

1095 10.63

1127 11.08

10200

926

8.22

958

8.83

990

9.40

 

1021

9.94

 

1053 10.46

1084 10.95

1116 11.42

1148 11.87

10600

948

9.05

980

9.66

1012 10.23

 

1043 10.77

 

1075 11.29

1106 11.78

1138 12.25

1170 12.70

11000

970

9.92

1003 10.52

1034 11.09

 

1066 11.64

 

1097 12.15

1128 12.64

1160 13.11

1193 13.56

11400

993

10.82

1025 11.43

1057 12.00

 

1089 12.54

 

1120 13.06

1151 13.55

1183 14.02

1216 14.47

11800

1017 11.76

1049 12.37

1081 12.94

 

1112 13.48

 

1143 14.00

1175 14.49

1207 14.96

1239 15.41

12200

1040 12.74

1073 13.34

1104 13.91

 

1136 14.46

 

1167 14.97

1199 15.46

1231 15.93

1263 16.38

12600

1065 13.75

1097 14.35

1129 14.92

 

1160 15.47

 

1192 15.98

1223 16.47

1255 16.94

-

-

 

 

 

 

 

 

 

High Static 15 HP & Drive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Flow

 

 

 

 

Available External Static Pressure - IWG1

 

 

 

 

2.0

2.2

2.4

 

2.6

 

2.8

3.0

3.2

3.4

(CFM)

 

 

RPM BHP

RPM BHP

RPM BHP

RPM BHP

RPM BHP

RPM BHP

RPM BHP

RPM BHP

 

 

 

 

Standard 10 HP & Drive

 

 

 

 

 

 

High Static 15 HP & Drive

 

6600

1016

6.59

1050

7.00

1086

7.41

 

1123

7.81

 

1161

8.19

1202

8.58

1244

8.95

1289

9.33

7000

1031

7.07

1065

7.49

1101

7.89

 

1138

8.29

 

1176

8.68

1217

9.06

1259

9.44

1304

9.82

7400

1047

7.59

1081

8.01

1117

8.41

 

1154

8.81

 

1192

9.20

1233

9.58

1275

9.96

1320 10.34

7800

1064

8.14

1098

8.56

1134

8.97

 

1171

9.36

 

1209

9.75

1250 10.13

1292 10.51

1337 10.89

8200

1082

8.74

1116

9.16

1152

9.56

 

1189

9.96

 

1227 10.35

1268 10.73

1310 11.11

1355 11.49

8600

1101

9.37

1135

9.79

1170 10.20

 

1207 10.59

 

1246 10.98

1286 11.36

1329 11.74

1374 12.12

9000

1120 10.05

1154 10.46

1189 10.87

 

1226 11.27

 

1265 11.65

1305 12.04

1348 12.41

1393 12.79

9400

1140 10.76

1174 11.18

1209 11.58

 

1246 11.98

 

1285 12.37

1325 12.75

1368 13.13

1413 13.51

9800

1160 11.51

1195 11.93

1230 12.33

 

1267 12.73

 

1306 13.12

1346 13.50

1389 13.88

1434 14.26

10200

1182 12.30

1216 12.72

1251 13.12

 

1288 13.52

 

1327 13.91

1367 14.29

1410 14.67

1455 15.05

10600

1204 13.13

1238 13.55

1273 13.95

 

1310 14.35

 

1349 14.74

1389 15.12

1432 15.50

1477 15.88

11000

1226 14.00

1260 14.41

1296 14.82

 

1332 15.22

 

1371 15.60

1412 15.99

1454 16.36

1499 16.74

11400

1249 14.90

1283 15.32

1318 15.72

 

1355 16.12

 

1394 16.51

1434 16.89

-

-

-

-

11800

1272 15.84

1306 16.26

1342 16.66

 

1379 17.06

 

-

-

-

-

-

-

-

-

12200

1296 16.82

1330 17.23

-

-

 

-

-

 

-

-

-

-

-

-

-

-

12600

-

-

-

-

-

-

 

-

-

 

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

15 HP & Field Supplied Drive

 

 

1.Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.

2.See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.

3.kW = BHP x 0.82.

Standard 10 HP & Drive

Johnson Controls Unitary Products

51

Image 51
Contents Description ZJ/ZR ShownTable of Contents ZJ shown Component LocationTon Sunline Magnum Model Number Nomenclature NomenclatureFeatures and Benefits Standard FeaturesBalanced Heating Factory Installed Options Control Options Guide Specifications Field Installed AccessoriesGeneral Indoor Evaporator Fan Assembly DescriptionUnit Cabinet Gas Heating Section ZJ/ZR/ZF***N Models Outdoor Condenser Fan AssemblyRefrigerant Components Unit ControlsStandard Limited Warranties Unit Operating CharacteristicsOther Pre-engineered Accessories Available Electrical RequirementsReheat Mode Sequence Of Operation Normal ModeAlternate Mode Reheat Controls Part Reheat Control BoardRHB ZJ180-300 Physical Data Physical DataFilters ZR180-300 Physical Data No. speeds Number of motors Motor HP each AFUE% ZF180-300 Physical DataMin ZJ/ZR/ZF180-300 Unit LimitationsCapacity Performance ZJ180-300 Cooling CapacitiesZJ180 15 Ton 115F 125F ZJ210 17.5 Ton ZJ210 17.5 Ton ZJ240 20 Ton ZJ240 20 Ton ZJ300 25 Ton ZJ300 25 Ton ZR180 15 Ton ZR180-300 Cooling and Reheat CapacitiesZR180 15 Ton 35F 45F ZR180 15 Ton Alternate Reheat ModeSensible Capacity MBh ZR240 20 Ton 115F 125F ZR240 20 Ton Alternate Reheat Mode 75F 85F ZR300 25 Ton 115F 125F ZR300 25 Ton Alternate Reheat Mode 75F 85F ZF180 15 Ton ZF180-300 Cooling Capacities115F 125F ZF210 17.5 Ton ZF210 17.5 Ton ZF240 20 Ton ZF240 20 Ton ZF300 25 Ton ZF300 25 Ton ZJ210 17.5 Ton Side Duct Airflow PerformanceZJ180-300 Side Duct Application ZJ180 15 Ton Side DuctZJ240 20 Ton Side Duct ZJ300 25 Ton Side Duct ZJ180-300 Bottom Duct Application ZJ180 15 Ton Bottom DuctZJ210 17.5 Ton Bottom Duct ZJ240 20 Ton Bottom Duct ZJ300 25 Ton Bottom Duct ZR180-300 Side Duct Application ZR180 15 Ton Side DuctZR240 20 Ton Side Duct ZR300 25 Ton Side Duct ZR180-300 Bottom Duct Application ZR180 15 Ton Bottom DuctZR240 20 Ton Bottom Duct ZR300 25 Ton Bottom Duct ZF180-300 Side Duct Application ZF180 15 Ton Side DuctZF210 17.5 Ton Side Duct ZF240 20 Ton Side Duct ZF300 25 Ton Side Duct ZF180-300 Bottom Duct Application ZF180 15 Ton Bottom DuctZF210 17.5 Ton Bottom Duct ZF240 20 Ton Bottom Duct ZF300 25 Ton Bottom Duct Additional Static Resistance RPM SelectionDrive Selection Correction Altitude/Temperature Correction FactorsAir Temperature ºF Gas Heat Minimum Supply Air FactorIndoor Blower Specifications Power Exhaust SpecificationsElectric Heat Minimum Supply Air ZJ/ZR/ZF Indoor Sound Power Levels Sound PerformanceElectric Heat Multipliers ZJ180-300 Standard Drive Without Powered Convenience Outlet Electrical DataZJ180 MCA Model Stages Amps ZJ180-300 Standard Drive With Powered Convenience OutletZJ180-300 Standard Drive With Powered Convenience Outlet Conv YTG-G-0708 ZJ180-300 High Static Drive With Powered Convenience Outlet ZJ180-300 High Static Drive With Powered Convenience Outlet ZJ300 Low Static Drive With Powered Convenience Outlet ZJ300 Low Static Drive Without Powered Convenience OutletZR180 ZR180-300 Standard Drive Without Powered Convenience OutletZR180-300 Standard Drive With Powered Convenience Outlet YTG-G-0708 ZR180-300 High Static Drive With Powered Convenience Outlet ZR300 Low Static Drive With Powered Convenience Outlet ZR300 Low Static Drive Without Powered Convenience OutletZF180 ZF180-300 Standard Drive Without Powered Convenience OutletPwr Max Fuse Motors ZF180-300 Standard Drive With Powered Convenience Outlet ZF180-300 Standard Drive With Powered Convenience Outlet ZF180-300 Hi Static Drive Without Powered Convenience Outlet ZF180-300 Hi Static Drive Without Powered Convenience Outlet ZF180-300 Hi Static Drive With Powered Convenience Outlet ZF180-300 Hi Static Drive With Powered Convenience Outlet ZF180-300 Low Static Drive With Powered Convenience Outlet ZJ180-300 Typical Control Diagram ZJ/ZR/ZF180-300 Wiring DiagramsOCC Terminal Block ZR180-300 Typical Control DiagramOCC ZF180-300 Typical Control DiagramWeights and Dimensions ZJ/ZR/ZF180-300 Unit WeightsZF Unit 4 Point Load Weight ZF Unit 6 Point Load Weight Supply Fan VFD Weights, in Lbs ZJ/ZR/ZF180-300 Unit Accessory WeightsZJ/ZR/ZF180-300 Unit Dimensions ZJ/ZR Unit Dimensions Front ViewUtilities Entry 48-5/8 15 Ton 52-5/8 17.5 thru 25 Ton ZF Unit Dimensions Front ViewZJ/ZR/ZF Unit Dimensions Rear View For bottom duct applicationsFor side duct applications ZJ/ZR/ZF180-300 Unit Clearances ZJ/ZR/ZF Unit Dimensions Rain HoodZJ/ZR/ZF180-300 Roof Curb ZJ/ZR/ZF180-300 Unit Accessory DimensionsZJ/ZR/ZF180-300 Typical Installation Johnson Controls Unitary Products York Drive Norman, OK
Related manuals
Manual 24 pages 22.74 Kb Manual 68 pages 3.65 Kb Manual 128 pages 30.42 Kb Manual 36 pages 24.83 Kb

R-410A specifications

York R-410A is a widely recognized and highly efficient refrigerant used in modern air conditioning systems. Developed as an environmentally friendly alternative to R-22, R-410A has gained popularity in the HVAC industry due to its numerous advantageous features and characteristics.

One of the main features of York R-410A is its ability to provide superior cooling performance. This refrigerant operates efficiently at both high and low temperatures, allowing systems using it to maintain optimal indoor climates even during extreme weather conditions. Its high energy efficiency ratio (EER) and seasonal energy efficiency ratio (SEER) ratings make it a preferred choice for energy-conscious consumers, resulting in lower energy bills and a reduced carbon footprint.

Technologically, York R-410A systems feature advanced compressor designs that enhance their overall reliability and performance. These compressors are often equipped with variable-speed technology, enabling them to adjust their output to match the cooling demands of the space. This not only improves comfort levels but also leads to efficient energy consumption, reducing wear and tear on the equipment over time.

Another significant characteristic of York R-410A is its non-ozone-depleting properties. Unlike its predecessor R-22, which is being phased out due to its damaging effects on the ozone layer, R-410A is designed to minimize environmental impact. Its lower global warming potential (GWP) further underscores its role in promoting sustainability within the HVAC sector.

Furthermore, York R-410A systems are engineered with enhanced safety features. The refrigerant is non-toxic and non-flammable, which makes it safer for use in both residential and commercial applications. Additionally, its high thermal stability reduces the risk of breakdown or leakage, contributing to longer system lifespans and lower maintenance costs.

In conclusion, York R-410A stands out as a cutting-edge refrigerant that combines efficiency, safety, and environmental responsibility. With its advanced technologies and remarkable characteristics, it meets the demands of modern air conditioning requirements while paving the way for a sustainable future in HVAC systems. Adopting York R-410A not only benefits individual users through improved comfort and lower energy bills but also plays a vital role in protecting our planet's ozone layer and mitigating climate change.