York R-410A manual Factory Installed Options

Page 6

251934-YTG-G-0708

can be reviewed at any time. Alarms and programmed values are retained through the loss of power.

Reliable - From the beginning - All units undergo computer automated testing before they leave the factory. Units are tested for refrigerant charge and pressure, unit amperage, and 100% functionality. For the long term - All units are painted with a long lasting, powder paint that stands up over the life of the unit. The paint used has been proven by a 1000 hour salt spray test.

Full Perimeter Base Rails - The permanently attached base rails provide a solid foundation for the entire unit and protect the unit during shipment. The rails offer rigging holes so that an overhead crane can be used to place the units on a roof.

Easy Installation - Gas and electric utility knockouts are supplied in the unit underside as well as the side of the unit. Utility connections can be made quickly and with a minimum amount of field labor. All units are shipped with 2" throw-away filters installed.

Wide Range of Indoor Airflows - All supply air blowers are equipped with a belt drive that can be adjusted to meet the exact requirements of the job. A high static drive option is available for applications with a higher CFM and/ or static pressure requirement.

Warranty - All models include a 1-year limited warranty on the complete unit. Compressors and electric heater elements each carry a 5-year warranty. Aluminized steel and stainless steel tubular heat exchangers carry a 10- year warranty.

Factory Installed Options

YORK® offers several equipment options factory installed, for the ZJ/ZR/ZF Series.

Single Input Electronic Enthalpy Economizers - Includes a slide-in /plug-in damper assembly with fully modulating spring-return motor actuator capable of introducing up to 100% outdoor air with nominal 1% leakage type dampers.

The enthalpy system contains one sensor that monitors the outdoor air and determines when the air is cool enough and dry enough to provide free cooling.

The rainhood is painted to match the basic unit and must be field-assembled before installing.

BAS-Ready Economizer - Includes a slide-in / plug-in damper assembly with fully modulating spring-return motor actuator with zero to 95-degree rotation capable of introducing up to 100% outdoor air with nominal 1% leakage type dampers.

Actuator requires 2-10 VDC input from an external source, such as a field-installed or factory-installed BAS controller. BAS-ready actuators have an adjustable auxiliary end-switch for optional power exhaust control.

For units with optional VAV or Simplicity® Intelli- Comfort™ control, a factory-installed, dry bulb sensor determines if outdoor air temperature is low enough to provide free-cooling operation. (Field-installed humidity sensors for either outdoor air or outdoor & return air

streams are available for single enthalpy and differential enthalpy configurations, respectively).

The rainhood is painted to match the basic unit and must be field-assembled before installing.

Power Exhaust - Our economizer options are available with power exhaust. Whenever the outdoor air intake dampers are opened for free cooling, the exhaust fan will be energized to prevent the conditioned space from being over-pressurized during economizer operation.

The exhaust fan, motor and controls are installed and wired at the factory. The rain hood must be assembled and installed in the field.

The power exhaust option can only be used on bottom duct configurations.

Motorized Outdoor Air Intake Damper - Includes a slide-in /plug-in damper assembly with a 2- position, spring return motor actuator which opens to a pre-set position whenever the supply air blower is operating and will drive fully closed when the blower unit shuts down. The rain hood is painted to match the basic unit and must be field assembled before installing.

Barometric Relief Damper - This damper option can be used to relieve internal building air pressure on units with an economizer without power exhaust. This accessory includes a rain hood, a bird screen and a fully assembled damper. With bottom duct connections, the damper should be mounted over the opening in the return air panel. With horizontal ductwork, the accessory should be mounted on the return air duct.

Phenolic Coated Evaporator And Condenser Coils - Special coating process that utilizes Technicoat 10-1" processes. Coating is applied by total immersion of the complete coil for maximum protection.

Electric Heaters - wired for single point power supply. These nickel chromium heater elements are provided with limit and automatic reset capability to prevent operation at excessive temperatures.

Variable Air Volume (VAV) - A factory-installed variable frequency drive (VFD), mounted in the Blower Access compartment, is used to control the speed of the indoor blower motor in order to maintain a constant static pressure in the supply duct. A pressure transducer and VAV control board are mounted inside the control box. The drive comes completely wired and pre-programmed from the factory.

An optional, factory-installed manual bypass switch available with factory-installed VFD can be found in the Blower Motor Access compartment. The switch can be used to either route power to the VFD for modulating control of the blower motor, to bypass the drive and operate the motor at full speed, or to power the drive (and not the motor) for diagnostic purposes.

Due to space limitations, VAV is not available with any of the factory-installed BAS options described below, but is available with ‘BAS-ready’ models. Terminal blocks are provided in the control box for field wiring of the customer- installed BAS.

6

Johnson Controls Unitary Products

Image 6
Contents ZJ/ZR Shown DescriptionTable of Contents Component Location ZJ shownNomenclature Ton Sunline Magnum Model Number NomenclatureFeatures and Benefits Standard FeaturesBalanced Heating Factory Installed Options Control Options Guide Specifications Field Installed AccessoriesGeneral Indoor Evaporator Fan Assembly DescriptionUnit Cabinet Unit Controls Outdoor Condenser Fan AssemblyRefrigerant Components Gas Heating Section ZJ/ZR/ZF***N ModelsElectrical Requirements Unit Operating CharacteristicsOther Pre-engineered Accessories Available Standard Limited WarrantiesReheat Mode Sequence Of Operation Normal ModeAlternate Mode Reheat Control Board Reheat Controls PartRHB Physical Data ZJ180-300 Physical DataFilters ZR180-300 Physical Data No. speeds Number of motors Motor HP each ZF180-300 Physical Data AFUE%ZJ/ZR/ZF180-300 Unit Limitations MinCapacity Performance ZJ180-300 Cooling CapacitiesZJ180 15 Ton 115F 125F ZJ210 17.5 Ton ZJ210 17.5 Ton ZJ240 20 Ton ZJ240 20 Ton ZJ300 25 Ton ZJ300 25 Ton ZR180-300 Cooling and Reheat Capacities ZR180 15 TonZR180 15 Ton ZR180 15 Ton Alternate Reheat Mode 35F 45FSensible Capacity MBh ZR240 20 Ton 115F 125F ZR240 20 Ton Alternate Reheat Mode 75F 85F ZR300 25 Ton 115F 125F ZR300 25 Ton Alternate Reheat Mode 75F 85F ZF180-300 Cooling Capacities ZF180 15 Ton115F 125F ZF210 17.5 Ton ZF210 17.5 Ton ZF240 20 Ton ZF240 20 Ton ZF300 25 Ton ZF300 25 Ton ZJ180 15 Ton Side Duct Airflow PerformanceZJ180-300 Side Duct Application ZJ210 17.5 Ton Side DuctZJ240 20 Ton Side Duct ZJ300 25 Ton Side Duct ZJ180-300 Bottom Duct Application ZJ180 15 Ton Bottom DuctZJ210 17.5 Ton Bottom Duct ZJ240 20 Ton Bottom Duct ZJ300 25 Ton Bottom Duct ZR180-300 Side Duct Application ZR180 15 Ton Side DuctZR240 20 Ton Side Duct ZR300 25 Ton Side Duct ZR180-300 Bottom Duct Application ZR180 15 Ton Bottom DuctZR240 20 Ton Bottom Duct ZR300 25 Ton Bottom Duct ZF180-300 Side Duct Application ZF180 15 Ton Side DuctZF210 17.5 Ton Side Duct ZF240 20 Ton Side Duct ZF300 25 Ton Side Duct ZF180-300 Bottom Duct Application ZF180 15 Ton Bottom DuctZF210 17.5 Ton Bottom Duct ZF240 20 Ton Bottom Duct ZF300 25 Ton Bottom Duct RPM Selection Additional Static ResistanceDrive Selection Factor Altitude/Temperature Correction FactorsAir Temperature ºF Gas Heat Minimum Supply Air CorrectionIndoor Blower Specifications Power Exhaust SpecificationsElectric Heat Minimum Supply Air ZJ/ZR/ZF Indoor Sound Power Levels Sound PerformanceElectric Heat Multipliers ZJ180-300 Standard Drive Without Powered Convenience Outlet Electrical DataZJ180 MCA ZJ180-300 Standard Drive With Powered Convenience Outlet Model Stages AmpsZJ180-300 Standard Drive With Powered Convenience Outlet Conv YTG-G-0708 ZJ180-300 High Static Drive With Powered Convenience Outlet ZJ180-300 High Static Drive With Powered Convenience Outlet ZJ300 Low Static Drive Without Powered Convenience Outlet ZJ300 Low Static Drive With Powered Convenience OutletZR180-300 Standard Drive Without Powered Convenience Outlet ZR180ZR180-300 Standard Drive With Powered Convenience Outlet YTG-G-0708 ZR180-300 High Static Drive With Powered Convenience Outlet ZR300 Low Static Drive Without Powered Convenience Outlet ZR300 Low Static Drive With Powered Convenience OutletZF180-300 Standard Drive Without Powered Convenience Outlet ZF180Pwr Max Fuse Motors ZF180-300 Standard Drive With Powered Convenience Outlet ZF180-300 Standard Drive With Powered Convenience Outlet ZF180-300 Hi Static Drive Without Powered Convenience Outlet ZF180-300 Hi Static Drive Without Powered Convenience Outlet ZF180-300 Hi Static Drive With Powered Convenience Outlet ZF180-300 Hi Static Drive With Powered Convenience Outlet ZF180-300 Low Static Drive With Powered Convenience Outlet ZJ/ZR/ZF180-300 Wiring Diagrams ZJ180-300 Typical Control DiagramZR180-300 Typical Control Diagram OCC Terminal BlockZF180-300 Typical Control Diagram OCCWeights and Dimensions ZJ/ZR/ZF180-300 Unit WeightsZF Unit 4 Point Load Weight ZF Unit 6 Point Load Weight ZJ/ZR/ZF180-300 Unit Accessory Weights Supply Fan VFD Weights, in LbsZJ/ZR/ZF180-300 Unit Dimensions ZJ/ZR Unit Dimensions Front ViewUtilities Entry ZF Unit Dimensions Front View 48-5/8 15 Ton 52-5/8 17.5 thru 25 TonZJ/ZR/ZF Unit Dimensions Rear View For bottom duct applicationsFor side duct applications ZJ/ZR/ZF Unit Dimensions Rain Hood ZJ/ZR/ZF180-300 Unit ClearancesZJ/ZR/ZF180-300 Unit Accessory Dimensions ZJ/ZR/ZF180-300 Roof CurbZJ/ZR/ZF180-300 Typical Installation Johnson Controls Unitary Products York Drive Norman, OK
Related manuals
Manual 24 pages 22.74 Kb Manual 68 pages 3.65 Kb Manual 128 pages 30.42 Kb Manual 36 pages 24.83 Kb

R-410A specifications

York R-410A is a widely recognized and highly efficient refrigerant used in modern air conditioning systems. Developed as an environmentally friendly alternative to R-22, R-410A has gained popularity in the HVAC industry due to its numerous advantageous features and characteristics.

One of the main features of York R-410A is its ability to provide superior cooling performance. This refrigerant operates efficiently at both high and low temperatures, allowing systems using it to maintain optimal indoor climates even during extreme weather conditions. Its high energy efficiency ratio (EER) and seasonal energy efficiency ratio (SEER) ratings make it a preferred choice for energy-conscious consumers, resulting in lower energy bills and a reduced carbon footprint.

Technologically, York R-410A systems feature advanced compressor designs that enhance their overall reliability and performance. These compressors are often equipped with variable-speed technology, enabling them to adjust their output to match the cooling demands of the space. This not only improves comfort levels but also leads to efficient energy consumption, reducing wear and tear on the equipment over time.

Another significant characteristic of York R-410A is its non-ozone-depleting properties. Unlike its predecessor R-22, which is being phased out due to its damaging effects on the ozone layer, R-410A is designed to minimize environmental impact. Its lower global warming potential (GWP) further underscores its role in promoting sustainability within the HVAC sector.

Furthermore, York R-410A systems are engineered with enhanced safety features. The refrigerant is non-toxic and non-flammable, which makes it safer for use in both residential and commercial applications. Additionally, its high thermal stability reduces the risk of breakdown or leakage, contributing to longer system lifespans and lower maintenance costs.

In conclusion, York R-410A stands out as a cutting-edge refrigerant that combines efficiency, safety, and environmental responsibility. With its advanced technologies and remarkable characteristics, it meets the demands of modern air conditioning requirements while paving the way for a sustainable future in HVAC systems. Adopting York R-410A not only benefits individual users through improved comfort and lower energy bills but also plays a vital role in protecting our planet's ozone layer and mitigating climate change.