HP 8200 tower manual Real-Time Clock and Configuration Memory, Clearing Cmos

Page 42

System Support

4.4 Real-Time Clock and Configuration Memory

The Real-time clock (RTC) and configuration memory (also referred to as “CMOS”) functions are provided by the 82801 component and is MC146818-compatible. As shown in the following figure, the 82801 PCH component provides 256 bytes of battery-backed RAM divided into two 128-byte configuration memory areas. The RTC uses the first 14 bytes (00-0Dh) of the standard memory area. All locations of the standard memory area (00-7Fh) can be directly accessed using conventional OUT and IN assembly language instructions through I/O ports 70h/71h, although the suggested method is to use the INT15 AX=E823h BIOS call.

0Dh

Register D

0Ch

Register C

0Bh

Register B

0Ah

Register A

09h

Year

08h

Month

07h

Date of Month

06h

Day of Week

05h

Hours (Alarm)

04h

Hours (Timer)

03h

Minutes (Alarm)

02h

Minutes (Timer)

01h

Seconds (Alarm)

00h

Seconds (Timer)

82801

Extended Config.

Memory Area

(128 bytes)

Standard Config.

Memory Area

(114 bytes)

RTC Area (14 bytes)

FFh

80h

7Fh

0Eh

0Dh

00h

CMOS

Figure 4-4. Configuration Memory Map

A lithium 3-VDC battery is used for maintaining the RTC and configuration memory while the system is powered down. During system operation a wire-Ored circuit allows the RTC and configuration memory to draw power from the power supply. The battery is located in a battery holder (XBT1) on the system board and has a life expectancy of three or more years. When the battery has expired it is replaced with a CR2032 or equivalent 3-VDC lithium battery.

4.4.1 Clearing CMOS

The contents of configuration memory can be cleared by the following procedure:

1.Turn off the unit.

2.Disconnect the AC power cord from the outlet and/or system unit.

3.Remove the chassis hood (cover) and insure that no LEDs on the system board are illuminated.

4.On the system board, press and hold the CMOS clear button (switch SW50, colored yellow) for at least 5 seconds.

5.Replace the chassis hood (cover).

6.Reconnect the AC power cord to the outlet and/or system unit.

7.Turn the unit on.

The above procedure does not clear the Power On Password. To clear the Power-On Password refer to section 4.5.1.

4-8

www.hp.com

Technical Reference Guide

Image 42
Contents Technical Reference Guide MarchTechnical Reference Guide Contents Processor/Memory Subsystem System SupportInput/Output Interfaces Power and Signal Distribution Integrated Graphics SubsystemError Messages and Codes IndexAdditional Information Sources IntroductionAbout this Guide Online Viewing HardcopySpecial Notices Serial NumberNotational Conventions ValuesCommon Acronyms and Abbreviations Acronyms and AbbreviationsAcronym or Abbreviation Description CGA Eide IRQ Nvram SDR Uart Introduction System Overview IntroductionFeatures HP Uefi BiosFeature Differences by Form Factor Usdt SFF CMTSystem Architecture Architectural Differences by Form FactorFunction HP Compaq 8200 Elite Business PC Architecture, Block diagram Intel Processor Support ChipsetSupport Component Functions Support ComponentsSystem Memory Component Name FunctionUniversal Serial Bus Interface Mass Storage AccommodationsLegacy Input/Output Interfaces Network Interface ControllerGraphics Subsystem Audio SubsystemHP ProtectTools Embedded Security Power Supply Electrical Specifications SpecificationsEnvironmental Specifications Factory Configuration Parameter Operating Non-operatingPhysical Specifications ParameterSFF CMT System Overview Processor/Memory Subsystem Processor/Memory Subsystem ArchitectureIntel Processor Features Specifications of Supported Intel ProcessorsIntel Processor Processor Changing/Upgrading Memory Subsystem Memory Socket Loading Memory UpgradingMemory Mapping and Pre-allocation Channel B Channel a Socket TotalSystem Memory Map for maximum of 8 gigabytes System Support PCI Bus OverviewPCI 2.3 Bus Operation Software/Driver Layer PCI Request/Grant SignalsPCI Express Bus Operation Transaction Protocol LayerPCI Interrupts PCI Power Management SupportOption ROM Mapping Link LayerPCI Connectors PCI 2.3 ConnectorPCI 2.3 Bus Connector Pinout PCIe Connectors PCIe Bus Connector PinoutInterrupts Apic ModeSystem Resources ModeDirect Memory Access System Board System Interrupts Pirq ConnectorPCI Interrupt Distribution Real-Time Clock and Configuration Memory Clearing CmosStandard Cmos Locations Configuration Memory Cmos MapSystem Management Security FunctionsCable Lock Provision Power-On / Setup PasswordSetup Password Interface SecurityAcpi Wake-Up Events Power ManagementSmart Cover Lock Optional Acpi Wake-Up Event System Wakes FromSystem Status PowerLED Beeps Action Required System StatusSystem Operational Status LED Indications Register Map and Miscellaneous Functions Thermal Sensing and CoolingSystem I/O Map System I/O Map Port FunctionGpio Functions PCH-DO FunctionsSIO Controller Functions System Support Input/Output Interfaces Sata interface Pin Sata Connector PinoutSATA/eSATA Interfaces Pin DescriptionOptional eSATA Bracket/Cable Assembly ESATA interfaceDB-9 Serial Connector Pinout Pin Signal DescriptionSerial Interface Extended Capabilities Port Mode Standard Parallel Port ModeEnhanced Parallel Port Mode Parallel Interface SupportParallel Interface Connector DB-25 Parallel Connector PinoutPin Signal Function Keyboard/Pointing Device Interface Keyboard Interface OperationKeyboard/Pointing Device Interface Connectors Keyboard/Pointing Device Connector PinoutPointing Device Interface Operation USB Signals USB Connector Location see note below Universal Serial Bus InterfacePCH USB Port Mapping USB Cable Data USB ConnectorUSB Connector Pinout USB Cable Length DataAudio Subsystem PCH-D0HD Audio Controller HD Audio Link BusAudio Multistreaming Audio Specifications HD Audio Subsystem SpecificationsParameter Measurement Network Interface Controller 10. LAN LED IndicationsFunction Activity LED Speed LED Power Management Support NIC ConnectorWake-On-LAN Support NIC Specifications 11. NIC SpecificationsParameter Compatibility standard orprotocol Integrated Graphics Subsystem Functional DescriptionSupported Intel Processor IGC Specifications System Memory Installed Pre-allocated IGC Memory Allocation with Windows XPIGC Memory Allocation with Windows Vista or Windows IGC Supported Resolutions Resolution Analog Digital DisplayPortMaximum Refresh Rate Monitor Connectors UpgradingDB-15 Monitor Connector Pinout Analog Monitor ConnectorDisplayPort Connector Pin SignalPower and Signal Distribution Power DistributionUsdt Power Distribution Usdt Power Supply SpecificationsParameter Watt supply 2 SFF/MT/CMT Power Distribution Power Supply Unit 4 3 2SFF 240-Watt Power Supply Unit Specifications MT/CMT 320-Watt Power Supply Unit SpecificationsPower Button Actions Power ControlPower Button Pressed Power Button ResultsPower LED Indications Power LED ConditionPower Management Wake Up EventsState System Condition System Power StatesPower Transition OS Restart Consumption To S0 by RequiredSignal Distribution System Board Connector, Indicator, and Switch DesignationsDesignator Component function SW1 Shows pinouts of headers used on the system boards Power and Signal Distribution System Bios ROM Flashing UpgradingChangeable Splash Screen Boot Functions Boot Device OrderNetwork Boot F12 Support Memory Detection and Configuration Boot Error CodesBoot Error Codes Visual power LED Audible speaker MeaningFunction Mode Client Management FunctionsClient Management Functions INT15 USB Legacy Support Smbios SupportTemperature Status System ID and ROM TypeManagement Engine Functions Table A-1. Beep/Power LED Codes Error Messages and CodesBeep/Power LED Codes Beeps Power LED Probable CausePower-On Self Test Post Messages Directory. Do not power down system untilProcessing is complete Board For systems with 2 Sata ports Root directory. Do not power down system until System Error Messages Table A-3 System Error Messages Probable CauseTable A-4 Memory Error MessagesMemory Error Messages Message Probable CauseKeyboard Error Messages Table A-5 Keyboard Error Messages Probable CauseTable A-6 Printer Error Messages Probable Cause Printer Error MessagesVideo Graphics Error Messages Table A-7 Video Graphics Error Messages Probable CauseDiskette Drive Error Messages Table A-8 Diskette Drive Error Messages Probable CauseSerial Interface Error Messages Table A-9 Serial Interface Error Messages Probable CauseModem Communications Error Messages System Status Error Messages System Status Error MessagesTable A-11 Hard Drive Error Messages Table A-12 Hard Drive Error Messages Probable CauseXx = 03, Hard drive read/write compare test Table A-13 Hard Drive Error Messages Probable Cause Audio Error Messages Table A-14 Video Graphics Error Messages Probable CauseTable A-15 Audio Error Messages Probable Cause DVD/CD-ROM Error Messages 17 DVD/CD-ROM Error MessagesNetwork Interface Error Messages Table A-17 Network Interface Error Messages Probable CauseScsi Interface Error Messages 65xx-xx, 66xx-xx Table A-18 Scsi Interface Error MessagesPointing Device Interface Error Messages 8601-xx Index NumericsIndex
Related manuals
Manual 6 pages 24 Kb Manual 29 pages 22.5 Kb Manual 13 pages 15.59 Kb

8200 tower specifications

The HP 8200 Tower is a robust desktop computer designed for professional environments, delivering performance and expandability for a variety of business needs. This workstation is part of HP's Elite series, known for its reliability and advanced technologies, making it a sound choice for companies requiring consistent operation.

One of the defining features of the HP 8200 Tower is its versatile processing power, powered by the Intel Core i5 and i7 processors. These processors offer a multi-core architecture, ensuring that users can efficiently handle multitasking and processor-intensive applications. With options for up to 32GB of DDR3 RAM, the HP 8200 Tower can smoothly run multiple applications simultaneously, making it suitable for tasks ranging from everyday office work to more demanding software like graphical design programs.

The system also provides a range of storage options, including traditional hard disk drives and faster solid-state drives, allowing users to select the balance of capacity and speed that best suits their needs. Additionally, the HP 8200 supports RAID configurations, enhancing data redundancy and performance, thereby protecting critical business data.

In terms of expandability, the HP 8200 Tower offers multiple PCIe slots for adding graphic cards, sound cards, or other expansion cards. This capability makes it adaptable for various purposes, whether that involves improving graphics performance for video editing or integrating specialized hardware for specific business functions.

The design of the HP 8200 Tower ensures efficient cooling and quiet operation. It features a tool-less chassis, allowing for easy upgrades and maintenance. The internal layout maximizes airflow, keeping components cool even under heavy workloads, an important feature for maintaining long-lasting performance.

Connectivity options are plentiful, with USB 2.0 and USB 3.0 ports, enabling speedy data transfer and peripheral connectivity. Additionally, integrated Gigabit Ethernet offers reliable networking capabilities, essential for seamless communication within a business environment.

The HP 8200 Tower showcases HP's commitment to sustainability, featuring energy-efficient components and a design aimed at reducing environmental impact. Overall, this powerful workstation combines performance, expandability, and energy efficiency, making it an excellent choice for any professional setting. With its blend of modern technologies and traditional reliability, the HP 8200 Tower stands out as a dependable tool for businesses looking to enhance productivity.