Page 18

035-16328-Rev002C(0902).

UPPER

I LIMIT SWITCH

BLU

CRY

 

RED

 

 

 

 

WALL

 

 

 

 

BRN

THERMOSTAT

 

 

 

 

BRN

TO A]C

__,J

 

 

 

 

CONDENSING

 

 

 

 

 

 

 

 

 

UNIT (if equipped)

 

 

 

X

 

 

 

 

 

 

 

 

m

O

 

 

BLK

 

BLK o

oI

o

ERL_

WHT

 

 

 

 

BLOW

RED

 

RED

 

 

MOTOR

 

 

 

 

 

 

 

o

WHT

 

 

 

 

 

 

 

 

 

ca L o;

WHT

 

TRANSFORMER

 

 

 

 

 

 

 

 

 

 

7

I I I TO EARTH GROUND

GROUND

 

 

SCRI

 

 

 

I

NEUTRAL

.... _A D-_

 

 

115

 

 

 

 

 

 

 

 

 

VAC

L1

 

 

 

BLK

 

 

 

 

 

INCOMING POWER MUST BE POLARIZED.

OBSERVE COLOR CODING.

LIMIT

ORGQ OWER SWITCH

YEL

i

©

COMBUSTION AIR

SWITCH

BLK

BLK

WHT

Or-o

WHT

O_w

;i3mc

5

Z

VAC

i c---..--

I GAS

SYSTEMI VALVE SWITCH

_----.--

HOT SURFACE

IGNITOR

FIGURE23 : Wiring Diagram for DGAA and DGAH Models

18

Unitary ProductsGroup

Image 18
Contents Models DGAA, DGAH, DGPA, and Dgph For Installation Manufactured Mobile HomesSealed Combustion Downflow GAS Furnace Furnace START-UP Check ListFurnace Specifications Electrical SpecificationsGeneral Information Installation StandardsHigh Altitude Installation CodecomplianceAIR Distribution Systems Closet InstallationsReturn AIR Requirements Transition ductBelow the top of the furnace casing Door7900-7771/C * White Installation in Snow Regions Existing Furnace ReplacementNEW Home Installation Roof Jack4900-7141/C 4000-6141/A 4000-6101/A4000-61211A 4000-6151/ARoof Jack With Removable Crowns Unitary Products Group Rear Wall Enclosure Ceiling CUT-OUT Duct ConnectorsDuct Connector Dimensions Supply DuctUnitary Products Group Installation of Screw Abachmentduct ConnectorInstallation of TAB Attachment Duct Connectors Locator BracketInstallation of the Furnace Tened to the furnaceConnect Thermostat Wires Electrical WiringConnect Power Supply Wires Ceiling RingsNot Factoryinstalled Wall ThermostatWiring Diagrams Limitswitch Manual Reset WHT Limit SwitciRED AMP Fuse Auto Reset NEU WHT SwitchORG Blower Relay GRY BLEND-AIR Limit Control BOX Switch If EquippedBLU WHT Auto Reset Limit Switch System LineAuto Reset Limit Switch Pressure AJC Condensing Unit Contactor NEU WHT SwitchFAN Switch Blower ORG Motor Combustion Relay GRYIncoming Power Must be Polarized Observe Color Coding Ca L oGAS Piping Installation and Checking of GAS LinePilot Adjustment Observing Burner OperationFinish and Trim Final Procedure Install Furnace DoorsFurnace and AIR Conditioner Base DuctHigh Altitude Deration Chart Natural GASPropane GAS DGAA,DGAH Repair Parts ListDGAA, Dgah DGPA, Dgph Control BOX DetailDgaa Description DGAA056BDTA DGAA070BDTA DGAA077BDTA DGAA09OBDTADgah ItemdescriptionDGAH056BBSA DGAH077BBSA Dgpa Description DGPA086ABTA DGPA070ABTA DGPA077ABTA DGPA090ABTADgph Description DGPH056ABTA DGPH070ABTA DGPH077ABTDGPH090ABTA Accessory Parts List Description Dgaa Dgah Dgpa Dgph ModelSupersedes

DGPA056ABTA, DGAAO77BDTA, DGAHO77BBSA, DGPA070ABTA, DGPA090ABTA specifications

York DGPA070ABTA, DGAA056BDTA, DGPA090ABTA, DGPA077ABTA, and DGPH077ABTA are part of York’s latest series of air conditioning and heat pump units, designed to meet the evolving demands of residential and commercial applications. These models combine efficiency with advanced technology to provide optimal climate control throughout the year.

The DGPA070ABTA stands out for its impressive cooling capacity, making it suitable for medium-sized spaces. Equipped with a high seasonal energy efficiency ratio (SEER), it maximizes cooling performance while minimizing energy consumption. This model is integrated with advanced inverter technology, allowing for variable speed operation. This means that the compressor can adjust its speed based on the cooling or heating demand, ensuring consistent temperatures and reduced energy waste.

The DGAA056BDTA model is tailored for users seeking a balance between performance and efficiency. This air conditioner features a dual-stage compressor that enables it to operate at reduced capacity during milder conditions, resulting in lower energy costs. Its compact design is ideal for installations where space is limited, and it offers a whisper-quiet operation, making it particularly attractive for residential settings.

Next is the DGPA090ABTA, which boasts one of the highest capacities in this range, making it capable of cooling larger areas effectively. It employs a state-of-the-art refrigerant that not only improves efficiency but also reduces environmental impact. This model's smart grid compatibility allows for easier integration with home automation systems, enabling users to monitor and control their cooling systems remotely.

The DGPA077ABTA serves as a versatile option for both residential and commercial users. This model features a robust build designed for durability and longevity. With its advanced filtration system, it ensures cleaner air circulation, enhancing indoor air quality. It also has programmable settings, allowing users to define schedules that align with their lifestyle.

Finally, the DGPH077ABTA model is a high-efficiency heat pump, providing both heating and cooling capabilities. This dual functionality makes it an attractive choice for regions with variable climates. The heat pump operates efficiently even in low temperatures, ensuring comfort no matter the season.

In summary, the York DGPA070ABTA, DGAA056BDTA, DGPA090ABTA, DGPA077ABTA, and DGPH077ABTA units encapsulate the brand’s commitment to innovation, efficiency, and user-centric design. These models utilize advanced technologies to ensure dependable performance, enhancing indoor comfort while being mindful of energy consumption and environmental impacts.