York DGAHO77BBSA, DGPHO56ABTA Dgpa, Description DGPA086ABTA DGPA070ABTA DGPA077ABTA DGPA090ABTA

Page 25

035-16328-Rev002C(0902).

DGPA

ITEM

 

 

 

DESCRIPTION

DGPA086ABTA

DGPA070ABTA

DGPA077ABTA

DGPA090ABTA

 

Switch, Pressure

.......

 

 

024-27666-000

2

Tubing Silicone (2'Req'd)

........

 

 

028-11957-000

 

LimitSwitch,Manual(Upper)

025-35358-000

025-35358-000

025-35358_000

025-35358-000

4

Assembly,

Booster (w/Motor)

........

 

 

373-19601-820

 

Control

Board, Integrated

..........

 

 

 

6

Valve, Gas

 

7956-336P

7956-336P

7956-336P

7956-336P

7

Bracket, Valve

073-19801-064

073-19601-064

073-19801-064

073-19801-064

8

Thermostat

(Heat/Cool)

 

Accessory

(See Page 6)

 

9

Exchanger,

Heat (w/Gaskets)

373-19804-651

373-19805-651

373-19806451

373-19806-650

10

Sensor,

 

Flame

..........

 

 

 

 

Switch,

System

7681-3301

7681-3301

7681-3301

7681-3301

 

Transformer (115-24V, 46 VA)

2940A3541

2940A3541

2946A3541

2940A3541

 

Switch,

Limit

025-35380-000

025-35380-069

025-35381-000

925-35381-000

14

Standing

Pilot, Burner Assembly

373-19801-401

373-19801-401

373-19801-401

373-19801*402

 

Includes

items 10 & 15)

 

 

 

 

15

Ignitor, Hot Surface

........

 

 

 

16

Filter (2 Req'd)(16x20xl)

1214-2511

1214-2511

1214-2511

1214-2511

17

Panel, Door (Upper)

 

Accessory

(See Page 6)

 

18

Panel, Door(Lower, Tall)

373-19801-740

373-19801-746

373-19801-740

373-19801-740

 

Motor (See

Note 3)

024-31948-000

024-31948-000

024-31948-000

024-31949-900

20

Assembly,

Motor Mount

..........

 

 

 

21

Plug, Connector

028-21192-000

025-21192_000

028-21192-000

025-21192-000

 

Capacitor,

Run

.....

 

 

024-20045-000

23

Wheel,

Blower

1472-2761

1472-2761

1472-2761

1472-2761

 

Relay, Fan

 

3110-3301

3116-3301

3119-3391

3110-3301

25

Relay, Booster

.......

 

 

3110-3301

 

Switch,

Fan

7975-3281

7975-3281

7975-3281

7975-3281

27

Thermocouple

7945-3481

7945-3481

7945-3481

7945-3481

28

Burner, Pilot

9680-0141

9880-0141

9880-0141

9880-0141

29

Tube, Pilot

 

029-22188-600

029-22188-000

029-22168-006

029-22188-960

30*

Diagram, tA_dng

035-15287-001

035-15287-001

035-15287-001

035-15288-001

NOTE: *Not Shown

New replacement pa_s shown in bold face type at the first pdnting of parts list dated 9/02 Major components and suggested stocking items are shown with shaded item numbe_ "<" Across from row indicates a change in that row.

--Not applicable to specJfiedmodel.

3.DGPA with 4 or S-TonBlowers are provided as an accessory item and are not standard equipment from the factory See Page 6

Unitary Products Group

25

Image 25
Contents Sealed Combustion Downflow GAS Furnace For Installation Manufactured Mobile HomesModels DGAA, DGAH, DGPA, and Dgph Furnace START-UP Check ListElectrical Specifications Furnace SpecificationsHigh Altitude Installation Installation StandardsGeneral Information CodecomplianceReturn AIR Requirements Closet InstallationsAIR Distribution Systems Transition ductDoor Below the top of the furnace casing7900-7771/C * White NEW Home Installation Existing Furnace ReplacementInstallation in Snow Regions Roof Jack4000-61211A 4000-6101/A4900-7141/C 4000-6141/A 4000-6151/ARoof Jack With Removable Crowns Unitary Products Group Duct Connector Dimensions Duct ConnectorsRear Wall Enclosure Ceiling CUT-OUT Supply DuctInstallation of TAB Attachment Duct Connectors Installation of Screw Abachmentduct ConnectorUnitary Products Group Locator BracketTened to the furnace Installation of the FurnaceConnect Power Supply Wires Electrical WiringConnect Thermostat Wires Ceiling RingsWall Thermostat Not FactoryinstalledWiring Diagrams RED AMP Fuse Auto Reset Manual Reset WHT Limit SwitciLimitswitch NEU WHT SwitchBLU WHT Auto Reset Limit Switch System BLEND-AIR Limit Control BOX Switch If EquippedORG Blower Relay GRY LineFAN Switch AJC Condensing Unit Contactor NEU WHT SwitchAuto Reset Limit Switch Pressure Blower ORG Motor Combustion Relay GRYCa L o Incoming Power Must be Polarized Observe Color CodingPilot Adjustment Installation and Checking of GAS LineGAS Piping Observing Burner OperationFurnace and AIR Conditioner Final Procedure Install Furnace DoorsFinish and Trim Base DuctNatural GAS High Altitude Deration ChartPropane GAS DGAA, Dgah DGPA, Dgph Repair Parts ListDGAA,DGAH Control BOX DetailDescription DGAA056BDTA DGAA070BDTA DGAA077BDTA DGAA09OBDTA DgaaItemdescription DgahDGAH056BBSA DGAH077BBSA Description DGPA086ABTA DGPA070ABTA DGPA077ABTA DGPA090ABTA DgpaDescription DGPH056ABTA DGPH070ABTA DGPH077ABT DgphDGPH090ABTA Model Accessory Parts List Description Dgaa Dgah Dgpa DgphSupersedes

DGPA056ABTA, DGAAO77BDTA, DGAHO77BBSA, DGPA070ABTA, DGPA090ABTA specifications

York DGPA070ABTA, DGAA056BDTA, DGPA090ABTA, DGPA077ABTA, and DGPH077ABTA are part of York’s latest series of air conditioning and heat pump units, designed to meet the evolving demands of residential and commercial applications. These models combine efficiency with advanced technology to provide optimal climate control throughout the year.

The DGPA070ABTA stands out for its impressive cooling capacity, making it suitable for medium-sized spaces. Equipped with a high seasonal energy efficiency ratio (SEER), it maximizes cooling performance while minimizing energy consumption. This model is integrated with advanced inverter technology, allowing for variable speed operation. This means that the compressor can adjust its speed based on the cooling or heating demand, ensuring consistent temperatures and reduced energy waste.

The DGAA056BDTA model is tailored for users seeking a balance between performance and efficiency. This air conditioner features a dual-stage compressor that enables it to operate at reduced capacity during milder conditions, resulting in lower energy costs. Its compact design is ideal for installations where space is limited, and it offers a whisper-quiet operation, making it particularly attractive for residential settings.

Next is the DGPA090ABTA, which boasts one of the highest capacities in this range, making it capable of cooling larger areas effectively. It employs a state-of-the-art refrigerant that not only improves efficiency but also reduces environmental impact. This model's smart grid compatibility allows for easier integration with home automation systems, enabling users to monitor and control their cooling systems remotely.

The DGPA077ABTA serves as a versatile option for both residential and commercial users. This model features a robust build designed for durability and longevity. With its advanced filtration system, it ensures cleaner air circulation, enhancing indoor air quality. It also has programmable settings, allowing users to define schedules that align with their lifestyle.

Finally, the DGPH077ABTA model is a high-efficiency heat pump, providing both heating and cooling capabilities. This dual functionality makes it an attractive choice for regions with variable climates. The heat pump operates efficiently even in low temperatures, ensuring comfort no matter the season.

In summary, the York DGPA070ABTA, DGAA056BDTA, DGPA090ABTA, DGPA077ABTA, and DGPH077ABTA units encapsulate the brand’s commitment to innovation, efficiency, and user-centric design. These models utilize advanced technologies to ensure dependable performance, enhancing indoor comfort while being mindful of energy consumption and environmental impacts.