York DGAAO77BDTA, DGPHO56ABTA Dgph, Description DGPH056ABTA DGPH070ABTA DGPH077ABT, DGPH090ABTA

Page 26

035-16328-Rev002C(0902).

DGPH

ITEM

DESCRIPTION

DGPH056ABTA

DGPH070ABTA

DGPH077ABT/

Switch, Pressure

DGPH090ABTA

024-27666-000

2 Tubing Silicone (2'Req'd}

LimitSwitch,Manual(Upper)025-35358-000

4Assembly, Booster (w/Motor) Control Board, Integrated

6

Valve, Gas

 

7956-336P

7

Bracket, Valve

073-19801-064

8

Thermostat

(Heat Only)

 

9

Exchanger,

Heat (w/Gaskets)

373-19504451

10

!Sensor,

Flame

 

 

Switch,

System

7970-3331

 

Transformer

(115-24V, 40 VA)

2940A3541

 

Switch,

Limit

025-35380-000

14

Standing Pilot, Burner Assembly

373-19801401

 

Includes items 10 & 15)

 

15

Ignitor,

Hot Surface

 

16

Filter (2 Req'd)(16x2Ox1)

1214-2511

17

Panel,

Door (Upper)

 

18

Panel, Door

(Lower, Tall)

373-19801-740

 

Motor

(See

Note 3)

024-31948-000

20

Assembly, Motor Mount

 

21

Plug, Connector

025-21192-000

 

Capacitor, Run

 

23

Wheel, Blower

1472-2761

 

Relay,

Fan

 

 

25

Relay,

Booster

 

26

Switch,

Fan

 

7975-3281

27

Thermocouple

7945-3481

28

Burner,

Pilot

 

9880-0141

29

Tube, Pilot

 

029-22188-000

30

Diagram, Wiring

035-15285-001

NOTE: *Not Shown

025-35358-000 025-35358-000

7956-336P7956-336P

073-19801-064 073-19801-064

Accessory (See Page 6)

373-19805_651 373-19806451

---n_

7970-33317970-3331

2940A35412940A3541

025-35380-000 025-35381-000

373-19801-401 373-19801401

1214-25111214-2511 Accessory(See Page 6)

373-19801-740 373-19801-740

024-31948-000 024-31948-000

---_.

025-21192-000 025-21192-000

__=

1472-27611472-2761

7975-32817975-3281

7945-34817945-3481

9880-01419880-0141

029*22185-000 029-22188-000

035-15285-001 035-15285-001

028-11957-000

025-35358-000

373-19801-820

7956-336P

073-19801-064

373-19806-650

7970-3331

2940A3541

025-35381-000

373-19801-402

1214-2511

373-19801-740

024-31949-000

025-21192-000

024-20045-000

1472-2761

3110-3301

7975-3281

7945-3481

9880-0141

029-22188-900

035-15286-001

New replacement parts shown in bold face type at the first printing of parts list dated 9/02. Major components and suggested stocking items are shown with shaded item numpen

"<= Across from row indimate$ a change in that row.

-- Not applicable to specified model.

3.DGPH with 4 or 5-Ton Blowers are provided as an accessory item and are not standard equipment from the factory. See page 6.

26

Unitary Products Group

Image 26
Contents Models DGAA, DGAH, DGPA, and Dgph For Installation Manufactured Mobile HomesSealed Combustion Downflow GAS Furnace Furnace START-UP Check ListFurnace Specifications Electrical SpecificationsGeneral Information Installation StandardsHigh Altitude Installation CodecomplianceAIR Distribution Systems Closet InstallationsReturn AIR Requirements Transition duct7900-7771/C * White Below the top of the furnace casingDoor Installation in Snow Regions Existing Furnace ReplacementNEW Home Installation Roof Jack4900-7141/C 4000-6141/A 4000-6101/A4000-61211A 4000-6151/ARoof Jack With Removable Crowns Unitary Products Group Rear Wall Enclosure Ceiling CUT-OUT Duct ConnectorsDuct Connector Dimensions Supply DuctUnitary Products Group Installation of Screw Abachmentduct ConnectorInstallation of TAB Attachment Duct Connectors Locator BracketInstallation of the Furnace Tened to the furnaceConnect Thermostat Wires Electrical WiringConnect Power Supply Wires Ceiling RingsNot Factoryinstalled Wall ThermostatWiring Diagrams Limitswitch Manual Reset WHT Limit SwitciRED AMP Fuse Auto Reset NEU WHT SwitchORG Blower Relay GRY BLEND-AIR Limit Control BOX Switch If EquippedBLU WHT Auto Reset Limit Switch System LineAuto Reset Limit Switch Pressure AJC Condensing Unit Contactor NEU WHT SwitchFAN Switch Blower ORG Motor Combustion Relay GRYIncoming Power Must be Polarized Observe Color Coding Ca L oGAS Piping Installation and Checking of GAS LinePilot Adjustment Observing Burner OperationFinish and Trim Final Procedure Install Furnace DoorsFurnace and AIR Conditioner Base DuctPropane GAS High Altitude Deration ChartNatural GAS DGAA,DGAH Repair Parts ListDGAA, Dgah DGPA, Dgph Control BOX DetailDgaa Description DGAA056BDTA DGAA070BDTA DGAA077BDTA DGAA09OBDTADGAH056BBSA DGAH077BBSA DgahItemdescription Dgpa Description DGPA086ABTA DGPA070ABTA DGPA077ABTA DGPA090ABTADGPH090ABTA DgphDescription DGPH056ABTA DGPH070ABTA DGPH077ABT Accessory Parts List Description Dgaa Dgah Dgpa Dgph ModelSupersedes

DGPA056ABTA, DGAAO77BDTA, DGAHO77BBSA, DGPA070ABTA, DGPA090ABTA specifications

York DGPA070ABTA, DGAA056BDTA, DGPA090ABTA, DGPA077ABTA, and DGPH077ABTA are part of York’s latest series of air conditioning and heat pump units, designed to meet the evolving demands of residential and commercial applications. These models combine efficiency with advanced technology to provide optimal climate control throughout the year.

The DGPA070ABTA stands out for its impressive cooling capacity, making it suitable for medium-sized spaces. Equipped with a high seasonal energy efficiency ratio (SEER), it maximizes cooling performance while minimizing energy consumption. This model is integrated with advanced inverter technology, allowing for variable speed operation. This means that the compressor can adjust its speed based on the cooling or heating demand, ensuring consistent temperatures and reduced energy waste.

The DGAA056BDTA model is tailored for users seeking a balance between performance and efficiency. This air conditioner features a dual-stage compressor that enables it to operate at reduced capacity during milder conditions, resulting in lower energy costs. Its compact design is ideal for installations where space is limited, and it offers a whisper-quiet operation, making it particularly attractive for residential settings.

Next is the DGPA090ABTA, which boasts one of the highest capacities in this range, making it capable of cooling larger areas effectively. It employs a state-of-the-art refrigerant that not only improves efficiency but also reduces environmental impact. This model's smart grid compatibility allows for easier integration with home automation systems, enabling users to monitor and control their cooling systems remotely.

The DGPA077ABTA serves as a versatile option for both residential and commercial users. This model features a robust build designed for durability and longevity. With its advanced filtration system, it ensures cleaner air circulation, enhancing indoor air quality. It also has programmable settings, allowing users to define schedules that align with their lifestyle.

Finally, the DGPH077ABTA model is a high-efficiency heat pump, providing both heating and cooling capabilities. This dual functionality makes it an attractive choice for regions with variable climates. The heat pump operates efficiently even in low temperatures, ensuring comfort no matter the season.

In summary, the York DGPA070ABTA, DGAA056BDTA, DGPA090ABTA, DGPA077ABTA, and DGPH077ABTA units encapsulate the brand’s commitment to innovation, efficiency, and user-centric design. These models utilize advanced technologies to ensure dependable performance, enhancing indoor comfort while being mindful of energy consumption and environmental impacts.