HP EMS HARDWARE S B6191-90028 manual Selecting Protocols for Sending Events Notify Via, Opcmsg ITO

Page 76

Using the Peripheral Status Monitor

Monitoring Request Parameters

interval is the maximum amount of elapsed time before EMS will be aware of a change in status for the hardware resource being monitored. A short polling interval will ensure that you have recent data. However, a short polling interval may use more CPU and system resources. You must weigh the importance of being able to respond quickly against the importance of maintaining good system performance.

Some considerations include:

MC/ServiceGuard monitors resources every few seconds. You may want to use a short polling interval (30 seconds or less) when it is critical that you make a quick failover decision.

You may want a polling interval of 5 minutes or so for monitoring less critical resources.

You may want to set a very long polling interval (4 hours) to monitor failed disks that are not essential to the system, but which should be replaced in the next few days.

Selecting Protocols for Sending Events - <Notify Via>

Using the <Notify via> option, you can specify the method EMS uses to send events. The options are:

opcmsg ITO

This option sends messages to ITO applications via the opcmsg daemon. IT Operation 4.0 or above must be installed on the resource server for this option to display.

The ITO message severity options are:

Critical

Major

Minor

Warning

Normal

A specified severity other than Normal is returned under the following conditions:

The When value is . . . condition evaluates to TRUE

The When value changes condition evaluates to TRUE

See the HP OpenView IT/Operations Administrators Task Guide (Part Number B4249-90003) for more information on configuring notification severity.

Templates for configuring IT/Operations and Network Node events can be found on the Hewlett-Packard High Availability public web page at http://www.hp.com/go/ha.

To set the opcmsg ITO:

1.Specify the notification type from the <Notify> list.

2.Select the opcmsg ITO option from the <Notify via> list.

3.Select the severity from the <Severity> list, (Critical, Major, Minor, Warning, Normal).

SNMP traps

This option sends messages to applications using SNMP traps, such as Network Node Manager. See HP OpenView Using Network Node Manager (P/N J1169-90002) for more information on configuring SNMP traps.

The following traps are used by EMS:

76

Chapter 4

Image 76
Contents EMS Hardware Monitors Users Guide Manufacturing Part Number B6191-90028 SeptemberLegal Notices Printing History Page Contents Using the Peripheral Status Monitor Hardware Monitor Configuration FilesSpecial Procedures Contents About This Manual Related Web Site Introduction What is Hardware Monitoring? Hardware Monitoring OverviewHow Does Hardware Monitoring Work? Components Involved in Hardware MonitoringBenefits of Hardware Monitoring Products Supported by Hardware Monitors Tips for Hardware Monitoring Hardware Monitoring Terms Hardware Monitoring TermsTerm Definition Hardware Monitoring Terms Introduction Hardware Monitoring Overview Chapter Installing and Using Monitors Steps Involved Steps for Installing and Configuring Hardware Monitoring Installing EMS Hardware Monitors Supported System ConfigurationRemoving EMS Hardware Monitors Disk Arrays Checking for Special RequirementsProduct Model/Product Special Number Requirements Disk Products Tape Products all supported by the Scsi Tape Devices MonitorHigh Availability Storage Systems Fibre Channel Scsi MultiplexersFibre Channel Arbitrated Loop FC-AL Hub Fibre Channel AdaptersProduct Model/Product Special Requirements Number Memory Fibre Channel SwitchSystem Interface Cards OthersWhat Is a Monitoring Request? Using Hardware Monitoring RequestsSome Monitoring Request Examples Building a Monitoring Request Running the Monitoring Request Manager To run the Monitoring Request Manager, typeEnabling Hardware Event Monitoring 13 Default Monitoring Requests for Each Monitor Default Monitoring RequestsSeverity Levels Notification Method Listing Monitor Descriptions To list the descriptions of available monitorsViewing Current Monitoring Requests To view or show the current monitoring requestsAdding a Monitoring Request To add a monitoring request14 Monitoring Requests Configuration Settings Setting DescriptionEvent Description MC/ServiceGuard Severity Response Level 15 Event Severity LevelsEvent Severity Levels Example of Adding a Monitoring Request == ADD Comment Modifying Monitoring Requests To modify a monitoring requestVerifying Hardware Event Monitoring Checking Detailed Monitoring Status Events =Retrieving and Interpreting Event Messages Sample Event MessageDeleting Monitoring Requests To delete a monitoring requestTo disable hardware event monitoring Disabling Hardware Event MonitoringDetailed Description Detailed Picture of Hardware Monitoring Hardware Monitoring ArchitectureComponents from Three Different Applications Hardware Monitoring Request ManagerPolling or Asynchronous? EMS Hardware Event MonitorStartup Client Event Monitoring Service EMS Peripheral Status Monitor PSM1File Locations File LocationsDirectories and Files Description Startup Process in Detail Monitoring Startup ProcessDisabling Monitoring Asynchronous Event Detection in Detail Event DecodingAsynchronous Event Detection Process Event Polling in Detail FC-AL Hub and FC Switch Polling ProcessesMemory Monitor Polling Monitoring Polling Process Memory Monitor Polling Process Detailed Picture of Hardware Monitoring Chapter Using the Peripheral Status Monitor Peripheral Status Monitor Overview How Does the PSM Work? Peripheral Status Monitor PSM Components PSM StatesPSM Resource Paths PSM StatusHow Does the PSM Work? Chapter Configuring Package Dependencies using SAM To create a package resource dependencyResourcepollinginterval Resourceupvalue =UP To create a PSM monitoring request Creating EMS Monitoring Requests for PSMFrom the Actions menu select Add Monitoring Request Specifying When to Send Event Notify Setting the Polling Interval Polling IntervalMonitoring Request Parameters Determining the Frequency of Events OptionsSelecting Protocols for Sending Events Notify Via Opcmsg ITOCritical Major Minor Normal To set the opcmsg ITOTo set the Snmp trap TCP and UDPTo set the TCP or UDP conditions To set for email notificationAdding a Notification Comment Comment Copying Monitoring Requests To change the monitoring parameters of a request Removing Monitoring Requests To remove monitoring requestsTo view the parameters for a monitoring request Viewing Monitoring RequestsFrom the Actions menu select View Monitoring Request To restore the operating state of a resource to UP Using the setfixed Utility to Restore Hardware UP StateExample 4-1 Example of Using setfixed Using the Peripheral Status Monitor Hardware Monitor Configuration Files Monitor Configuration Files Monitor Configuration File Entries Setting Values DescriptionFile Names File FormatInterval must be a Eventnum must be aFrequency must be a Sample Global Configuration File Event DefinitionSeverity Action Polling IntervalSample Monitor-Specific Configuration File = Communication Device#POLLINTERVAL Startup Configuration File Startup Configuration File Entries Keyword Values DescriptionUDP Default Monitoring Requests Default File EntriesDescription Entry Peripheral Status Monitor PSM Configuration File Considerations for Modifying the PSM Configuration File PSM Configuration File Fields MonitorresourcenameCritical Downseverityope Example File Entries Special Procedures Fibre Channel Arbitrated Loop Hub Monitor Initial Monitor Configuration Configuring the FC-AL Monitor Configuration FileConfiguration Files Adding or Removing an FC-AL HubSetting Default Description Value This setting is requiredPSM Configuration File Fibre Channel Switch Monitor Adding or Removing an FC Switch Configuring the FC Switch Monitor Configuration FileChanging the FC Switch Monitoring Configuration 2PSM Configuration File Fields Special Procedures 112 Index 114 115