Special Procedures
Fibre Channel Arbitrated Loop Hub Monitor
Fibre Channel Arbitrated Loop Hub Monitor
History
• IPR 9902: Initial release
Supported Products
•Fibre Channel Arbitrated Loop Hub Model A3724A
•Fibre Channel Arbitrated Loop Hub Model A4839A
Special Requirements
The
Device Firmware revisions:
•Device Agent Firmware revision 2.14 or greater
•Hub Controller Firmware revision 3.06 or greater
Firmware and installation instructions are available at http://www.software.hp.com
C++ runtime support patches:
•10.20 PHSS_16585 (supersedes PHSS_14262)
•11.00 PHSS_16587 (supersedes PHSS_14577)
Before using the hub monitor, edit the monitor configuration file, /var/stm/config/tools/monitor/dm_fc_hub.cfg, to indicate what hubs will be monitored. See “Configuring the
Resource Path
Event monitoring: /connectivity/events/hubs/FC_hub
Status monitoring: /connectivity/status/hubs/FC_hub
Executable File
/usr/sbin/stm/uut/bin/tools/monitor/dm_fc_hub
Monitor Behavior
•The monitor uses polling only with a default interval of 60 minutes.
•At initial startup the monitor does not retrieve any log information from the hub.
PSM State Control
The monitor does not support automatic state control. The set_fixed utility must be used to return a hardware resource to the UP state following a failure. See “Configuring the
102 | Chapter 6 |