HP DL370 manual HP R1500 G2 UPS, HP R3000 UPS, HP R3000v Uninterruptible Power System

Page 35

QuickSpecs

HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6)

Additional Options

Uninterruptible Power Systems - Tower

HP T1000v Uninterruptible Power System

 

HP T1000v UPS

AF443A

NOTE: The T1000v is available in China and India only.

 

NOTE: Please see the QuickSpecs for additional information:

 

http://h18000.www1.hp.com/products/quickspecs/13130_div/13130_div.html

 

(Worldwide)

 

HP T1500 G3 UPS Models

 

HP T1500 G3 UPS, NA

AF450A

HP T1500 G3 UPS, INTL

AF451A

NOTE: Please see the QuickSpecs for additional information:

 

http://h18000.www1.hp.com/products/quickspecs/13160_div/13160_div.html

 

(Worldwide)

 

Uninterruptible Power Systems - Rack

HP R1500 G2 UPS

 

HP, R1.5kVA UPS, 1U, NA

AF419A

HP, R1.5kVA UPS, 1U, INTL

AF418A

HP, R1.5kVA UPS, 1U, JPN/TW

AF421A

NOTE: Please see the QuickSpecs for Technical Specifications and additional

 

information:

 

http://h18000.www1.hp.com/products/quickspecs/12507_div/12507_div.html

 

(Worldwide)

 

HP R3000 UPS

 

HP R3000 VA UPS, 2U, DTC, INTL

AF414A

HP R3000 VA UPS, 2U, L5-30, NA

AF422A

HP R3000 VA UPS, 2U, L6-20, NA

AF423A

HP R3000 VA UPS, 2U, L6-20, JPN

AF424A

HP R3000 VA UPS, 2U, L5-30, JPN

AF425A

NOTE: Please see the QuickSpecs for Technical Specifications and additional

 

information:

 

http://h18000.www1.hp.com/products/quickspecs/10671_div/10671_div.html

 

(Worldwide)

 

HP R3000v Uninterruptible Power System

 

HP R3000v UPS

AF444A

NOTE: The R3000v is available in China and India only.

 

NOTE: Please see the QuickSpecs for Technical Specifications and additional

 

information:

 

http://h18000.www1.hp.com/products/quickspecs/13129_div/13129_div.html

 

(Worldwide)

 

HP Rack-Mountable R5500 UPS

 

HP R5500 VA UPS, INTL

AF416A

HP R5500 VA UPS, NA/JPN

AF426A

NOTE: Please see the QuickSpecs for Technical Specifications and additional

 

information:

 

http://h18000.www1.hp.com/products/quickspecs/11871_div/11871_div.html

 

(Worldwide)

 

DA - 13242 Worldwide — Version 3 — April 2, 2009

Page 35

Image 35
Contents HP ProLiant DL370 G6 Rack Front View Rear View OverviewMemory Two processors Power supply bayHP ProLiant ML370 G6 Tower Front View Rear View ProcessorsInternal Drive Support Power SourcesDeployment/Serviceability Storage ControllerWarranty Standard Features DDR3 memory options part number decoder Network Controller Standard Entry Model GB 2 xMaximum Rdimm Maximum UdimmInterfaces StorageMaximum Internal Storage TypeControl suite GraphicsForm Factor 4U Rack and Tower form factor 7 in, 17.8 cm Essentials Server ManagementStand Alone Software Product ProLiantQuickSpecs Eliminate receiving unnecessary duplicate media Core InfrastructureSubscribers Choice Event notificationsServer profiles provided with the Rapid Deployment Pack Management Homepage please visit the management Web site atSecurity Industry StandardCompliance Key could result in data loss Server Power CordsPower Supply ModuleRequired Cabling OS Support Common Slot ProLiantSupply option kits see Redundant Options for part numbers System FansHP Enterprise ConfiguratorRack Airflow Rack 10000 series Cabinets Requirements Telco Rack SupportQuickSpecs Models Performance Model HP DL370 G6 Base ProcessorsDL370 E5530 6GB Cache Memory HP DL370 G6 ProcessorsXX=42 Europe Country Code Key Tower Code KeyHP ProLiant DL370 G6 Rack Models Configuration Information Factory Integrated ModelsModels HP ProLiant ML370 G6 Tower Models Factory Integrated Model ships withUnbuffered with ECC DIMMs UDIMMs Performance Pack part numbers in belowBase Memory Registered DIMMs RDIMMs Performance Packs ControllersIntegrated hypervisor Choose Additional Options for Factory Integration Processors Quad-Core Processors Core OptionsDL370 G6 Unique OptionsSAS Hot Plug 3.5 Enterprise ENT Drives Optical DrivesHard Drives SAS Hot Plug SFF Enterprise ENT DrivesHP NC524SFP Dual Port 10GbE Module 489892-B21 CommunicationsAdapters allowed in this server NC522SFP adapterHP Insight Control suite Additional Options483527-B21 Year of 24x7 Technical Support and UpdatesHP Insight Server Migration software for ProLiant Monitor HP Insight Dynamics-VSE suite for ProLiantActivation key and documentation HP Insight Power Manager IPMHP Integrated Lights-Out Advanced Pack Optimize HP Accelerated iSCSI PackSAS Controller Options Smart Array P212 ControllerSmart Array P410 Controller Smart Array P411 ControllerTape Drives Power CordsDisk-Based Backup RDX Removable Disk Backup D2D BackupHP StorageWorks MSL4048 Tape Library HP Serviceguard for Linux OptionsTape Autoloaders HP StorageWorks 1/8 G2 Tape Autoloader Tape Libraries HP StorageWorks MSL2024 Tape LibraryDrive MSL tape libraries to ProLiant servers StorageWorks Options StorageWorks Fibre Channel HBALinux. For detailed compatibility information please see StorageWorks Scsi HBAHP Rack-Mountable R5500 UPS HP R3000v Uninterruptible Power SystemHP R1500 G2 UPS HP R3000 UPSRack Kit HP Monitored Power Distribution Unit Full Rack VersionHP Monitored Power Distribution Unit Half Rack Version USB OptionsHP Rack 10000 G2 Series HP Rack 5000 SeriesGraphite Metallic HP 5642 Rack Unassembled 358254-B21 QuickSpecs HP 16 Port Serial Console Server worldwide AF101A Installation & Start-up Services Service and Support OfferingsHardware Services On-site Service Hardware Services 6-Hour Call to Repair On-site ServicePopulated Dimm Speed MHz MemoryRegistered Dimms RDIMMs Unbuffered with ECC DIMMs UDIMMs Quad Rank 4R Single Rank 1R Dual Rank 2RChnl Standard memory configuration 1 CPU modelPopulation order start with a first, B second, C third, etc Slot #72GB, consisting of nine 9 8GB dual-rank PC3-8500 RDIMMs Rdimm maximum configurationUdimm maximum configuration 1 CPU model Standard memory plus optional memory 1 CPU model144GB, consisting of eighteen 18 8GB PC3-8500 RDIMMs Udimm maximum configuration 2 CPU model1GB = 1024MB 2GB = 2048MB 4GB = 4096MB 8GB = 8192MB Storage Hard Drives SAS Hot Plug SFF Enterprise ENT Drives ControllerRemovable Media SAS Hot Plug 3.5 Midline MDL Drives Internal USB Tape Drives Tape and Disk-Based BackupExternal Storage Host Controller or AdapterSAS Tape Automation Removable Disk Backup System, InternalRemovable Disk Backup System, External Backup SystemsInput Voltage Range Vrms Power SpecificationsHP 460W Power Supply Part Number AC 460W PSU HP 750W Power Supply Part Number AC 750W PSUMaximum British Thermal Unit 3174 3530 4600 Rating BTU-Hr HP 1200W Power Supply Part Number ACVrms Technical Specifications Idle Relative HumidityAltitude Acoustic NoiseInterface Transfer rate Smart Array P410i DimensionsSAS Connectors Upgradeable FirmwareProducts and Approach Recycling ConnectorCable Support Environment-friendly