hp StorageWorks
QuickSpecsmodular SAN array 1000 specific for Tru64 UNIX and OpenVMS only
Technical Specifications
MODULAR SAN ARRAY 1000
LED Indicators on Front (3)  | Power  | 
  | 
  | Fault detected in one or more   | |
  | Fault in Enclosure Management  | |
  | 
  | 
  | 
LED Indicators for Drive  | Drive Access (centre)  | 
  | 
Modules (3)  | Online (left)  | 
  | 
  | 
  | |
  | Drive Failure (right)  | 
  | 
  | 
  | |
LED Indicators on Rear Panel  | Power Supply/Blower Assembly Fault (1)  | |
(4)  | EMU (3) Power, A bus, B bus  | 
  | 
  | 
  | |
  | 
  | 
  | 
Interface  | Ultra3 SCSI to Hard Drives  | 
  | 
  | 2 Gb Fibre Channel to Hosts  | 
  | 
  | 
  | |
Maximum Number of Drives | Fourteen,   | |
  | two additional StorageWorks 4200/4300 Enclosures  | |
Temperature Range  | Operating  | 50° to 95° F/10° to 35° C  | 
  | Shipping  | |
  | NOTE: Derated 1° C per 1,000 feet of elevation to 10,000 ft.  | |
  | 
  | 
  | 
Relative Humidity  | Operating  | 10% to 90%  | 
  | Up to 95%  | |
  | 
  | 
  | 
Input Power Requirements | Rated Input Voltage  | 100 to 240 VAC  | 
  | Rated Input Frequency  | 50 to 60 Hz  | 
  | Rated Input Current  | 6 A Max  | 
  | Input Power (max)  | 549 W*  | 
  | 
  | 
  | 
Heat Dissipation (max) | 1876 Btu/hr*  | 
  | 
  | * Input Power and Heat Dissipation specifications are maximum values and apply to   | |
  | rated power supply load. The power/heat dissipation for your installation will vary depending on the equipment  | |
  | configuration.  | 
  | 
msa1000 Cabinet | 4U Rack Form Factor  | 
  | 
  | Dimensions (H x W x D)  | 6.9 x 19 x 20.5 in/17.5 x 48.3 x 52.1 cm  | 
  | Weight  | Net 55 to 85 lb/24.95 to 38.56 kg  | 
  | 
  | 
  | 
Shipping Packaging | Dimensions (L x W x D)  | 28.5 x 14.81 x 33.13 in/72.4 x 37.6 x 84.1 cm  | 
  | Weight  | Gross 75 to 105 lb/34.02 to 47.63 kg  | 
Canada — Version 2 — April 15, 2003  | 15  |