hp StorageWorks
QuickSpecsmodular SAN array 1000 specific for Tru64 UNIX and OpenVMS only
MSA1000 Components
With the following components, your storage capacity and performance can be scaled to new levels
Modular SAN Array 1000 | The 4U cabinet houses up to fourteen 1” Universal hot pluggable Ultra2, Ultra3, and/or Ultra320 drives. Each | ||
| msa1000 includes the following standard components: (1) msa1000 Controller, (1) msa Fibre Channel I/O Module | ||
| with a single SFP, dual hot pluggable fans/power supplies and power cables, (2) 3’ VHDCI to VHDCI SCSI cables | ||
| to connect expansion enclosures, documentation and a CD Kit containing firmware upgrade code for Tru64 and | ||
| OpenVMS and a support software CD. |
| |
| The modular design of the msa1000 makes it possible to add redundant controllers, redundant single port Fibre | ||
| Channel I/O Modules, | ||
|
| ||
msa1000 Controller | The msa1000 Controller is an integrated RAID controller with an integrated LCD/LED status display and 256 MB | ||
| read/write | ||
| the msa1000; a redundant msa1000Controller is an option. | ||
| Key Features | • | Redundant controller support with mirrored cache |
|
| • | Fabric, Private Loop & Public Loop Support |
|
| • | Auto Negotiated F, FL & L Port Login |
|
| • | RAID 0, 1, 1+0, 5 and ADG |
|
| • | 2 Gb/1 Gb Frequency Agile |
|
| • | Primary & Secondary |
|
| • | configurable with Command Line Interface (CLI) |
|
|
|
|
| msa1000 Controller | • | Online RAID Level Migration: allows for online |
| Management Features |
| RAID level without destroying data or volume information. |
|
| • | Online Capacity Expansion: lets you add storage to an operational |
|
|
| |
|
| • | Global Online Spare: reduces the risk of data loss by facilitating automatic |
|
|
| rebuilds after a drive failure |
|
|
| |
| Fault Tolerance | Several fault tolerant configurations, which keep data available and servers | |
|
| running while drives are being replaced, are supported including: | |
|
| • | Advanced Data Guarding (RAID ADG): Allocates the equivalence of two |
|
|
| parity drives across multiple drives and allows simultaneous write |
|
|
| operations. |
|
| • | Distributed Data Guarding (RAID 5): Allocates parity data across multiple |
|
|
| drives and allows simultaneous write operations. |
|
| • | Drive Mirroring (RAID 1, (1+0 Striped Mirroring)): Allocates half of the drive |
|
|
| array to data and the other half to mirrored data, providing two copies of |
|
|
| every file. |
|
|
|
|
| Fault Recovery | • | Minimizes downtime, reconstructs data, and facilitates a quick recovery |
|
|
| from drive failure |
|
| • | Online Spares: If a failure occurs, recovery begins with an online spare and |
|
|
| data is reconstructed automatically. Multiple online spares can be |
|
|
| assigned per array and used across multiple arrays. It is also possible to |
|
|
| assign different online spares across different arrays. |
|
| • | Array Accelerator: Onboard, |
|
|
| the event of a power failure. In the unlikely event of a controller failure, the |
|
|
| |
|
| ||
msa Fibre Channel I/O Module | Provides a single 2 Gb Fibre Channel connection per controller from the host side into the msa1000. The msa | ||
| Fibre Channel I/O Module includes one 2 Gb, Short Wave, |
second msa Fibre Channel I/O Module can be installed for redundancy when a redundant controller is used.
Canada — Version 2 — April 15, 2003 | 4 |