York 300 warranty Sound Power RATING1, Capacity Ratings ARI, GAS Heat Ratiings

Page 12

 

 

 

 

 

 

 

 

 

 

 

 

 

036-21410-001-A-0502

TABLE 1: SOUND POWER RATING1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ESP

BLOWER

 

 

 

 

SOUND POWER (db 10-12Watts)

 

 

 

UNIT

 

 

 

 

 

 

 

 

 

 

 

 

CFM

 

 

 

 

 

Octave Band Centerline Frequency (Hz)

 

SWL

dB(A)

SIZE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

@

 

 

IWG

RPM

BHP

63

125

 

250

500

1,000

2,000

4,000

8,000

dB(A)

 

 

 

10Ft.2

 

 

 

 

180

6,000

1.00

1,080

4.60

99

99

 

89

82

84

77

72

67

89

56

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

210/240

8,000

1.00

1,120

6.65

102

102

 

92

85

87

80

75

70

92

59

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300

10,000

1.30

1160

12.5

108

108

 

98

91

93

86

81

76

98

65

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.These values have been accessed using a model of sound propagation from a point source into the hemispheric\free field. The dBA values provided are to be used for reference only. Calculation of dBA values cover matters of system design and the fan manufacture has no way of knowing the details of each system. This constitutes and expectation to any specification or guarantee requiring a dBA value or sound data in any other form than sound power level ratings.

2.At a distance of 10 feet from the blower.

TABLE 2: CAPACITY RATINGS - (ARI 360)1

MODEL

MBH

EER2

IPLV3

COOLING ONLY

 

 

 

 

 

 

 

DJ180C/E00

178

11.8

13.0

 

 

 

 

DJ210C/E00

208

11.7

12.7

 

 

 

 

DJ240C/E00

230

11.3

12.0

 

 

 

 

DJ300C/E00

292

10.5

11.2

 

 

 

 

COOLING WITH GAS HEAT

 

 

 

 

 

 

 

DJ180N/S

178

11.8

13.0

 

 

 

 

DJ210N/S

208

11.7

12.7

 

 

 

 

DJ240N/S

230

11.3

12.0

 

 

 

 

DJ300N/S

292

10.5

11.2

 

 

 

 

COOLING WITH ELECTRIC HEAT

 

 

 

 

 

 

DJ180E18

178

11.8

13.0

 

 

 

 

DJ180E36

178

11.8

13.0

 

 

 

 

DJ180E54

176

11.6

12.7

 

 

 

 

DJ180E72

176

11.6

12.7

 

 

 

 

DJ210E18

208

11.7

12.7

 

 

 

 

DJ210E36

208

11.7

12.7

 

 

 

 

DJ210E54

206

11.5

12.4

 

 

 

 

DJ210E72

206

11.5

12.4

 

 

 

 

DJ240E18

230

11.3

12.0

 

 

 

 

DJ240E36

230

11.3

12.0

 

 

 

 

DJ240E54

228

11.1

11.7

 

 

 

 

DJ240E72

228

11.1

11.7

 

 

 

 

DJ300E18

292

10.5

11.2

 

 

 

 

DJ300E36

292

10.5

11.2

 

 

 

 

DJ300E54

290

10.3

11.0

 

 

 

 

DJ300E72

290

10.3

11.0

 

 

 

 

1.Certified in accordance with the Unitary Large Equip- ment certification program which is based on ARI Stan- dard 340/360.

2.EER = Energy Efficiency Ratio at full load - the cooling capacity in Btu’s per hour (Btuh) divided by the power input in watts, expressed in Btuh per watt (Btuh/watt).

3.IPLV = Integrated Part Load Value.

TABLE 3: GAS HEAT RATIINGS

MODEL

MBH INPUT

MBH OUTPUT

 

 

 

DJ180N/S24

300

240

 

 

 

DJ180N/S32

400

320

 

 

 

DJ210N/S24

300

240

 

 

 

DJ210N/S32

400

320

 

 

 

DJ240N/S24

300

240

 

 

 

DJ240N/S32

400

320

 

 

 

DJ300N/S24

300

240

 

 

 

DJ300N/S32

400

320

 

 

 

NOTE: All gas units are two-stage heating. First stage is 50% of total.

S.S.E. = Steady State Efficiency (80%) - output divided by input.

12

Unitary Products Group

Image 12
Contents Technical Guide Table of Contents Sng Product Nomenclature Panels Johnson UNT Controller, DFS, APS & Phase Monitor Technicoat Condenser Coil, Phase Monitor, & Coil Guard Features FACTORY-INSTALLED Options FIELD-INSTALLED Accessories 036-21410-001-A-0502 Sound Power RATING1 Capacity Ratings ARIGAS Heat Ratiings Cooling Capacities for DJ180 AT 85F Cooling Capacities for DJ180 AT 95F Cooling Capacities for DJ180 AT 105F Cooling Capacities for DJ180 AT 115F Cooling Capacities for DJ180 AT 125F Cooling Capacities for DJ210 AT 85F 65007000 7875Cooling Capacities for DJ210 AT 95F Cooling Capacities for DJ210 AT 105F Cooling Capacities for DJ210 AT 115F Cooling Capacities for DJ210 AT 125F Cooling Capacities for DJ240 AT 85F 80008700 9400Cooling Capacities for DJ240 AT 95F Cooling Capacities for DJ240 AT 105F Cooling Capacities for DJ240 AT 115F Cooling Capacities for DJ240 AT 125F Cooling Capacities for DJ300 AT 85F 1000012500 Cooling Capacities for DJ300 AT 95F Cooling Capacities for DJ300 AT 105F Cooling Capacities for DJ300 AT 115F Cooling Capacities for DJ300 AT 125F Volt and Standard Drive Volt Standard Drive 6000 7000 8000 9000 9400 965 980 1025 1065 1125 1170 870 900 930 950 980 995 1015 6000 7000 8000 9000 9400 7500 8750 10000 11250 12500 Power Exhaust Performance Blower Motor and Drive DataStatic RESISTANCES1 DJ Electrical Data DJ Voltage LIMITATIONS1 Physical DataElectric Heat Correction Factors KW CAP. MultiplierUtilities Entry BackUnit Dimensions Rear View Unit Dimensions DJ180, 210, 240 & 300 Rainhood Four and SIX Point Loads Unit Roof Curb Dimensions DimensionOCC General DescriptionRefrigerant Components Other Factory Installed Options 036-21410-001-A-0502 036-21410-001-A-0502 036-21410-001-A-0502 Unitary 5005 Norman Products York Group Drive 73069