York 300 warranty DJ Electrical Data

Page 41

036-21410-001-A-0502

TABLE 34: DJ ELECTRICAL DATA

 

 

Compressors

OD Fan

 

 

Minimum

 

Model

 

ID Blower

 

Circuit

Max Fuse Size

Voltage

 

 

Motors

Heater kW

Tonnage

 

RLA Each

LRA Each

FLA Each

Motor FLA

 

Ampacity

Amps

 

 

 

 

Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

~

72.9

90

 

 

 

 

 

 

13.5

72.9

90

 

208

21.8

184

2.1

15.4

27.0

112.9

125

 

 

 

 

 

 

40.6

160.1

175

 

 

 

 

 

 

54.1

169.1

200

 

 

 

 

 

 

~

71.9

90

 

 

 

 

 

 

18.0

72.1

90

 

230

21.8

184

2.1

14.4

36.0

126.3

150

 

 

 

 

 

 

54.0

147.9

175

15

 

 

 

 

 

72.0

191.2

225

 

 

 

 

 

~

36.4

45

 

 

 

 

 

 

 

 

 

 

 

 

18.0

36.4

45

 

460

11

90

1.1

7.2

36.0

63.1

70

 

 

 

 

 

 

54.0

74

90

 

 

 

 

 

 

72.0

95.6

110

 

 

 

 

 

 

~

31.1

40

 

 

 

 

 

 

18.0

31.1

40

 

575

9.6

73

0.9

5.9

36.0

50.7

60

 

 

 

 

 

 

54.0

59.3

70

 

 

 

 

 

 

72.0

76.7

90

 

 

 

 

 

 

~

86.0

110

 

 

 

 

 

 

13.5

86.0

110

 

208

25.6

225

2.1

20

27.0

118.7

125

 

 

 

 

 

 

40.6

165.9

175

 

 

 

 

 

 

54.1

175.2

200

 

 

 

 

 

 

~

86.0

110

 

 

 

 

 

 

18.0

86.0

110

 

230

25.6

225

2.1

20

36.0

133.3

150

 

 

 

 

 

 

54.0

154.9

175

17.5

 

 

 

 

 

72.0

198.2

225

 

 

 

 

 

~

43.2

50

 

 

 

 

 

 

 

 

 

 

 

 

18.0

43.2

50

 

460

12.8

114

1.1

10

36.0

66.6

70

 

 

 

 

 

 

54.0

77.5

90

 

 

 

 

 

 

72.0

99.1

110

 

 

 

 

 

 

~

35.0

45

 

 

 

 

 

 

18.0

35.0

45

 

575

10.3

80

0.9

8.2

36.0

53.6

60

 

 

 

 

 

 

54.0

62.2

70

 

 

 

 

 

 

72.0

79.5

90

 

 

 

 

 

 

~

110.4

125

 

 

 

 

 

 

13.5

110.4

125

 

208

33.6

225

3.7

20

27.0

118.7

125

 

 

 

 

 

 

40.6

165.9

175

 

 

 

 

 

 

54.1

175.2

200

 

 

 

 

 

 

~

110.4

125

 

 

 

 

 

 

18.0

110.4

125

 

230

33.6

225

3.7

20

36.0

133.3

150

 

 

 

 

 

 

54.0

154.9

175

20

 

 

 

 

 

72.0

198.2

225

 

 

 

 

 

~

56.5

70

 

 

 

 

 

 

 

 

 

 

 

 

18.0

56.5

70

 

460

17.3

114

1.9

10

36.0

66.6

70

 

 

 

 

 

 

54.0

77.5

90

 

 

 

 

 

 

72.0

99.1

110

 

 

 

 

 

 

~

44.6

50

 

 

 

 

 

 

18.0

44.6

50

 

575

13.5

80

1.5

8.2

36.0

53.6

60

 

 

 

 

 

 

54.0

62.2

70

 

 

 

 

 

 

72.0

79.5

90

 

 

 

 

 

 

~

159.4

200

 

 

 

 

 

 

13.5

159.4

200

 

208

47.1

245

3.7

38.6

27.0

159.4

200

 

 

 

 

 

 

40.6

189.1

200

 

 

 

 

 

 

54.1

198.4

225

 

 

 

 

 

 

~

159.4

200

 

 

 

 

 

 

18.0

159.4

200

 

230

47.1

245

3.7

38.6

36.0

159.4

200

 

 

 

 

 

 

54.0

178.2

200

25

 

 

 

 

 

72.0

221.5

250

 

 

 

 

 

~

71.0

90

 

 

 

 

 

 

 

 

 

 

 

 

18.0

71.0

90

 

460

19.6

125

1.9

19.3

36.0

78.3

90

 

 

 

 

 

 

54.0

89.1

100

 

 

 

 

 

 

72.0

110.7

125

 

 

 

 

 

 

~

57.0

70

 

 

 

 

 

 

18.0

57.0

70

 

575

15.8

100

1.5

15.4

36.0

62.6

70

 

 

 

 

 

 

54.0

71.2

80

 

 

 

 

 

 

72.0

88.5

100

Unitary Products Group

41

Image 41
Contents Technical Guide Table of Contents Sng Product Nomenclature Panels Johnson UNT Controller, DFS, APS & Phase Monitor Technicoat Condenser Coil, Phase Monitor, & Coil Guard Features FACTORY-INSTALLED Options FIELD-INSTALLED Accessories 036-21410-001-A-0502 GAS Heat Ratiings Sound Power RATING1Capacity Ratings ARI Cooling Capacities for DJ180 AT 85F Cooling Capacities for DJ180 AT 95F Cooling Capacities for DJ180 AT 105F Cooling Capacities for DJ180 AT 115F Cooling Capacities for DJ180 AT 125F 6500 Cooling Capacities for DJ210 AT 85F7000 7875Cooling Capacities for DJ210 AT 95F Cooling Capacities for DJ210 AT 105F Cooling Capacities for DJ210 AT 115F Cooling Capacities for DJ210 AT 125F 8000 Cooling Capacities for DJ240 AT 85F8700 9400Cooling Capacities for DJ240 AT 95F Cooling Capacities for DJ240 AT 105F Cooling Capacities for DJ240 AT 115F Cooling Capacities for DJ240 AT 125F 12500 Cooling Capacities for DJ300 AT 85F10000 Cooling Capacities for DJ300 AT 95F Cooling Capacities for DJ300 AT 105F Cooling Capacities for DJ300 AT 115F Cooling Capacities for DJ300 AT 125F Volt and Standard Drive Volt Standard Drive 6000 7000 8000 9000 9400 965 980 1025 1065 1125 1170 870 900 930 950 980 995 1015 6000 7000 8000 9000 9400 7500 8750 10000 11250 12500 Static RESISTANCES1 Power Exhaust PerformanceBlower Motor and Drive Data DJ Electrical Data Physical Data DJ Voltage LIMITATIONS1KW CAP. Multiplier Electric Heat Correction FactorsBack Utilities EntryUnit Dimensions Rear View Unit Dimensions DJ180, 210, 240 & 300 Rainhood Four and SIX Point Loads Dimension Unit Roof Curb DimensionsOCC Description GeneralRefrigerant Components Other Factory Installed Options 036-21410-001-A-0502 036-21410-001-A-0502 036-21410-001-A-0502 Unitary 5005 Norman Products York Group Drive 73069