York 300 warranty Panels

Page 5

036-21410-001-A-0502

 

Additional Options

 

 

EB

Johnson UNT Controller, DFS, APS & Phase Monitor, Hinged Filter Door & Tooless Access Panels

 

 

EC

Johnson UNT Controller, DFS, APS & Coil Guard, Hinged Filter Door & Tooless Access Panels

 

 

ED

Johnson UNT Controller, DFS, APS, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels

 

 

EE

Johnson UNT Controller, DFS, APS & Technicoat Cond. Coil, Hinged Filter Door & Tooless Access Panels

 

 

EF

Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Tooless Access Panels

 

 

EG

Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Tooless Access Panels

 

 

EH

Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels

 

 

EJ

Johnson UNT Controller, DFS, APS & Technicoat Evap. Coil, Hinged Filter Door & Tooless Access Panels

 

 

EK

Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Tooless Access Panels

 

 

EL

Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Tooless Access Panels

 

 

EM

Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels

 

 

EN

Johnson UNT Controller, DFS, APS & Technicoat Evap. & Cond Coils, Hinged Filter Door & Tooless Access Panels

 

 

EP

Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Tooless Access Panels

 

 

EQ

Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Tooless Access Panels

 

 

ER

Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access

 

Panels

 

 

GA

Honeywell Excel 10 Controller with Dirty Filter Switch & Air Proving Switch, Hinged Filter Door & Tooless Access Panels

 

 

GB

Honeywell Excel 10 Controller, DFS, APS & Phase Monitor, Hinged Filter Door & Tooless Access Panels

 

 

GC

Honeywell Excel 10 Controller, DFS, APS & Coil Guard, Hinged Filter Door & Tooless Access Panels

 

 

GD

Honeywell Excel 10 Controller, DFS, APS, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels

 

 

GE

Honeywell Excel 10 Controller, DFS, APS & Technicoat Cond. Coil, Hinged Filter Door & Tooless Access Panels

 

 

GF

Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Tooless Access Panels

 

 

GG

Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Tooless Access Panels

 

 

GH

Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access

 

Panels

 

 

GJ

Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. Coil, Hinged Filter Door & Tooless Access Panels

 

 

GK

Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Tooless Access Panels

 

 

GL

Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Tooless Access Panels

 

 

GM

Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access

 

Panels

 

 

GN

Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. & Cond Coils, Hinged Filter Door & Tooless Access Panels

 

 

GP

Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Tooless Access

 

Panels

 

 

GQ

Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Tooless Access Panels

 

 

GR

Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless

 

Access Panels

 

 

HA

Honeywell Excel 10 Controller with Dirty Filter Switch & Air Proving Switch

 

 

HB

Honeywell Excel 10 Controller, DFS, APS & Phase Monitor

 

 

HC

Honeywell Excel 10 Controller, DFS, APS & Coil Guard

 

 

HD

Honeywell Excel 10 Controller, DFS, APS, Phase Monitor, & Coil Guard

 

 

HE

Honeywell Excel 10 Controller, DFS, APS & Technicoat Cond. Coil

 

 

HF

Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor

 

 

HG

Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard

 

 

HH

Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard

 

 

HJ

Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. Coil

 

 

HK

Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor

 

 

HL

Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard

 

 

HM

Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard

 

 

HN

Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. & Cond Coils

 

 

HP

Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor

 

 

HQ

Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard

 

 

HR

Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard

 

 

JA

Johnson UNT Controller with Dirty Filter Switch & Air Proving Switch

 

 

Unitary Products Group

5

Image 5
Contents Technical Guide Table of Contents Sng Product Nomenclature Panels Johnson UNT Controller, DFS, APS & Phase Monitor Technicoat Condenser Coil, Phase Monitor, & Coil Guard Features FACTORY-INSTALLED Options FIELD-INSTALLED Accessories 036-21410-001-A-0502 GAS Heat Ratiings Sound Power RATING1Capacity Ratings ARI Cooling Capacities for DJ180 AT 85F Cooling Capacities for DJ180 AT 95F Cooling Capacities for DJ180 AT 105F Cooling Capacities for DJ180 AT 115F Cooling Capacities for DJ180 AT 125F 6500 Cooling Capacities for DJ210 AT 85F7000 7875Cooling Capacities for DJ210 AT 95F Cooling Capacities for DJ210 AT 105F Cooling Capacities for DJ210 AT 115F Cooling Capacities for DJ210 AT 125F 8000 Cooling Capacities for DJ240 AT 85F8700 9400Cooling Capacities for DJ240 AT 95F Cooling Capacities for DJ240 AT 105F Cooling Capacities for DJ240 AT 115F Cooling Capacities for DJ240 AT 125F 12500 Cooling Capacities for DJ300 AT 85F10000 Cooling Capacities for DJ300 AT 95F Cooling Capacities for DJ300 AT 105F Cooling Capacities for DJ300 AT 115F Cooling Capacities for DJ300 AT 125F Volt and Standard Drive Volt Standard Drive 6000 7000 8000 9000 9400 965 980 1025 1065 1125 1170 870 900 930 950 980 995 1015 6000 7000 8000 9000 9400 7500 8750 10000 11250 12500 Static RESISTANCES1 Power Exhaust PerformanceBlower Motor and Drive Data DJ Electrical Data Physical Data DJ Voltage LIMITATIONS1KW CAP. Multiplier Electric Heat Correction FactorsBack Utilities EntryUnit Dimensions Rear View Unit Dimensions DJ180, 210, 240 & 300 Rainhood Four and SIX Point Loads Dimension Unit Roof Curb DimensionsOCC Description GeneralRefrigerant Components Other Factory Installed Options 036-21410-001-A-0502 036-21410-001-A-0502 036-21410-001-A-0502 Unitary 5005 Norman Products York Group Drive 73069