York 300 warranty Blower Motor and Drive Data, Static RESISTANCES1, Power Exhaust Performance

Page 40

036-21410-001-A-0502

TABLE 31: BLOWER MOTOR AND DRIVE DATA

 

 

 

 

 

MOTOR1

ADJUSTABLE MOTOR PULLEY

FIXED BLOWER PULLEY

 

BELT

 

 

 

BLOWER

 

(NOTCHED)

 

MODEL

 

 

 

 

 

 

 

 

 

 

 

 

 

DRIVE

RANGE

 

 

 

EFF.

DESIG-

OUTSIDE

PITCH

BORE

DESIG-

OUTSIDE

PITCH

BORE

DESIG-

PITCH

 

SIZE

 

(RPM)

 

 

 

 

 

HP

FRAME

(%)

NATION

DIA.

DIA.

(IN.)

NATION

DIA.

DIA.

(IN.)

NATION

LENGTH

QTY.

 

 

 

 

 

 

 

 

 

 

 

 

(IN.)

(IN.)

 

 

(IN.)

(IN.)

 

 

(IN.)

 

 

Standard

850/1065

 

 

 

 

 

 

 

 

BK90

8.75

8.4

1

BX81

82.8

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15 TON

High

965/1190

 

5

184 T

83

1VP56

5.35

4.3-5.32

1-1/8

BK80

7.75

7.4

1

BX78

79.8

1

 

Speed

 

 

 

 

 

 

 

 

 

Access

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard

870/1025

 

 

 

 

 

 

 

 

BK120

11.75

11.4

1-3/16

BX83

84.8

1

17.5 &

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High

 

 

7.5

213 T

89

1VP68

6.75

5.5-6.52

1-3/8

 

 

 

 

 

 

 

20 TON

950/1120

 

BK110

10.75

10.4

1-3/16

BX81

82.8

1

Speed

 

 

 

 

 

 

 

 

 

Access

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard

975/1165

 

 

 

 

 

 

 

 

1B5V110

11.3

11.1

1-7/16

5VX860

86.0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25 TON

High

1140/1365

 

15

254 T

91

1VP75X

7.5

6.2-7.42

1-5/8

1B5V94

9.7

9.5

1-7/16

5VX840

84.0

1

 

Speed

 

 

 

 

 

 

 

 

 

Access

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.All motors have a nominal speed of 1800 RPM, a 1.15 service factor and a solid base. They can operate to the limit of their service factor because they are located in the moving air, upstream of any heating device.

2.Do NOT close this pulley below 1 turn open.

TABLE 32: STATIC RESISTANCES1

 

 

 

 

 

 

 

 

RESISTANCE, IWG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DESCRIPTION

 

 

 

 

 

 

 

 

CFM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15 TON

 

 

17.5 TON

 

 

20 TON

 

 

25 TON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4500

6000

7200

6000

 

7500

 

9000

6000

8000

9400

7500

10000

12500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WET INDOOR COIL

0.1

0.1

0.1

0.1

 

0.1

 

0.1

0.1

0.1

0.1

0.11

0.11

0.11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18 KW

0.1

0.1

0.1

0.1

 

0.1

 

0.1

0.1

0.1

0.1

0.31

0.56

0.87

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRIC HEAT OPTIONS

36 KW

0.1

0.2

0.3

0.1

 

0.2

 

0.3

0.1

0.2

0.3

0.38

0.68

1.07

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

54 KW

0.2

0.3

0.4

0.2

 

0.3

 

0.4

0.2

0.3

0.4

0.62

1.10

1.72

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72 KW

0.2

0.4

0.6

0.2

 

0.4

 

0.6

0.2

0.4

0.6

0.68

1.21

1.90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ECONOMIZER OPTION

 

 

0.1

0.1

0.1

0.1

 

0.1

 

0.1

0.1

0.1

0.1

0.06

0.11

0.18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HORIZONTAL DUCT CONNECTIONS2

0.1

0.2

0.3

0.2

 

0.3

 

0.5

0.2

0.3

0.5

0.36

0.32

0.46

1.Deduct these resistance values from the available external static pressures shown in the respective Blower Performance Table (See Note 2 for exception.)

2.Since the resistance to air flow will be less for horizontal duct connections than for bottom duct connections, add these pressures to the ESP values on the respective unit’s blower performance table.

TABLE 33: POWER EXHAUST PERFORMANCE

MOTOR

 

 

 

STATIC RESISTANCE OF RETURN DUCTWORK, IWG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SPEED1

 

0.2

0.3

 

 

0.4

 

0.5

 

0.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

 

kW

CFM

kW

CFM

 

kW

CFM

 

kW

CFM

 

kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH2

5250

 

0.83

4500

0.85

4200

 

0.88

3750

 

0.93

3000

 

0.99

MEDIUM

4900

 

0.77

3900

0.79

3500

 

0.82

2900

 

0.85

-

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

4400

 

0.72

3700

0.74

3000

 

0.78

-

 

-

-

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Power exhaust motor is a 3/4 HP, PSC type with sleeve bearings, a 48 frame and inherent protection.

2.The factory setting.

40

Unitary Products Group

Image 40
Contents Technical Guide Table of Contents Sng Product Nomenclature Panels Johnson UNT Controller, DFS, APS & Phase Monitor Technicoat Condenser Coil, Phase Monitor, & Coil Guard Features FACTORY-INSTALLED Options FIELD-INSTALLED Accessories 036-21410-001-A-0502 Capacity Ratings ARI Sound Power RATING1GAS Heat Ratiings Cooling Capacities for DJ180 AT 85F Cooling Capacities for DJ180 AT 95F Cooling Capacities for DJ180 AT 105F Cooling Capacities for DJ180 AT 115F Cooling Capacities for DJ180 AT 125F Cooling Capacities for DJ210 AT 85F 65007000 7875Cooling Capacities for DJ210 AT 95F Cooling Capacities for DJ210 AT 105F Cooling Capacities for DJ210 AT 115F Cooling Capacities for DJ210 AT 125F Cooling Capacities for DJ240 AT 85F 80008700 9400Cooling Capacities for DJ240 AT 95F Cooling Capacities for DJ240 AT 105F Cooling Capacities for DJ240 AT 115F Cooling Capacities for DJ240 AT 125F 10000 Cooling Capacities for DJ300 AT 85F12500 Cooling Capacities for DJ300 AT 95F Cooling Capacities for DJ300 AT 105F Cooling Capacities for DJ300 AT 115F Cooling Capacities for DJ300 AT 125F Volt and Standard Drive Volt Standard Drive 6000 7000 8000 9000 9400 965 980 1025 1065 1125 1170 870 900 930 950 980 995 1015 6000 7000 8000 9000 9400 7500 8750 10000 11250 12500 Blower Motor and Drive Data Power Exhaust PerformanceStatic RESISTANCES1 DJ Electrical Data DJ Voltage LIMITATIONS1 Physical DataElectric Heat Correction Factors KW CAP. MultiplierUtilities Entry BackUnit Dimensions Rear View Unit Dimensions DJ180, 210, 240 & 300 Rainhood Four and SIX Point Loads Unit Roof Curb Dimensions DimensionOCC General DescriptionRefrigerant Components Other Factory Installed Options 036-21410-001-A-0502 036-21410-001-A-0502 036-21410-001-A-0502 Unitary 5005 Norman Products York Group Drive 73069