York 251934-YTG-J-0910 manual ZF300 25 Ton Side Duct

Page 61

251934-YTG-J-0910

ZF300 (25 Ton) Side Duct

Air Flow

 

 

 

 

Available External Static Pressure - IWG1

 

 

 

 

0.4

0.6

0.8

 

 

1.0

 

1.2

1.4

1.6

1.8

(CFM)

 

 

 

RPM BHP

RPM BHP

RPM BHP

 

RPM BHP

 

RPM BHP

RPM BHP

RPM BHP

RPM BHP

 

Low Static

7.5 HP &

 

 

 

 

 

 

 

Low Static 7.5 HP & Drive

 

 

 

 

 

Field Supplied Drive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6600

760

2.51

793

3.11

824

3.68

 

 

856

4.23

 

887

4.74

919

5.23

950

5.70

983

6.15

7000

775

2.99

808

3.60

839

4.17

 

 

871

4.71

 

902

5.22

934

5.72

966

6.19

998

6.64

7400

792

3.51

824

4.11

856

4.69

 

 

887

5.23

 

918

5.74

950

6.24

982

6.70

1014

7.16

7800

809

4.07

841

4.67

873

5.24

 

 

904

5.78

 

935

6.30

967

6.79

999

7.26

1031

7.71

8200

826

4.66

859

5.27

890

5.84

 

 

922

6.38

 

953

6.89

985

7.39

1016

7.86

1049

8.31

8600

845

5.30

877

5.90

909

6.47

 

 

940

7.01

 

972

7.53

1003

8.02

1035

8.49

1067

8.94

9000

864

5.97

896

6.57

928

7.14

 

 

960

7.69

 

991

8.20

1022

8.69

1054

9.16

1087

9.61

9400

884

6.68

916

7.28

948

7.86

 

 

980

8.40

 

1011

8.91

1042

9.41

1074

9.88

1107

10.33

9800

905

7.43

937

8.04

969

8.61

 

 

1000

9.15

 

1032

9.67

1063 10.16

1095

10.63

1127

11.08

10200

926

8.22

958

8.83

990

9.40

 

1021

9.94

 

1053 10.46

1084 10.95

1116

11.42

1148

11.87

10600

948

9.05

980

9.66

1012 10.23

1043 10.77

 

1075 11.29

1106 11.78

1138

12.25

1170

12.70

11000

970

9.92

1003 10.52

1034 11.09

 

1066 11.64

 

1097 12.15

1128 12.64

1160

13.11

1193

13.56

11400

993

10.82

1025 11.43

1057 12.00

1089 12.54

 

1120 13.06

1151 13.55

1183

14.02

1216

14.47

11800

1017 11.76

1049 12.37

1081 12.94

1112 13.48

 

1143 14.00

1175 14.49

1207

14.96

1239

15.41

12200

1040 12.74

1073 13.34

1104 13.91

1136 14.46

 

1167 14.97

1199 15.46

1231

15.93

1263

16.38

12600

1065 13.75

1097 14.35

1129 14.92

1160 15.47

 

1192 15.98

1223 16.47

1255

16.94

-

-

 

 

 

 

 

 

 

High Static 15 HP & Drive

 

 

 

 

 

 

Standard 10 HP & Drive

Air Flow

 

 

 

 

Available External Static Pressure - IWG1

 

 

 

 

2.0

2.2

2.4

2.6

2.8

3.0

3.2

3.4

(CFM)

RPM BHP

RPM BHP

RPM BHP

RPM BHP

RPM BHP

RPM BHP

RPM BHP

RPM BHP

 

 

 

 

Standard 10 HP & Drive

 

 

 

 

High Static 15 HP & Drive

 

6600

1016

6.59

1050

7.00

1086

7.41

1123

7.81

1161

8.19

1202

8.58

1244

8.95

1289

9.33

7000

1031

7.07

1065

7.49

1101

7.89

1138

8.29

1176

8.68

1217

9.06

1259

9.44

1304

9.82

7400

1047

7.59

1081

8.01

1117

8.41

1154

8.81

1192

9.20

1233

9.58

1275

9.96

1320 10.34

7800

1064

8.14

1098

8.56

1134

8.97

1171

9.36

1209

9.75

1250 10.13

1292 10.51

1337 10.89

8200

1082

8.74

1116

9.16

1152

9.56

1189

9.96

1227

10.35

1268 10.73

1310 11.11

1355 11.49

8600

1101

9.37

1135

9.79

1170

10.20

1207

10.59

1246

10.98

1286 11.36

1329 11.74

1374 12.12

9000

1120

10.05

1154

10.46

1189

10.87

1226

11.27

1265

11.65

1305 12.04

1348 12.41

1393 12.79

9400

1140

10.76

1174

11.18

1209

11.58

1246

11.98

1285

12.37

1325 12.75

1368 13.13

1413 13.51

9800

1160

11.51

1195

11.93

1230

12.33

1267

12.73

1306

13.12

1346 13.50

1389 13.88

1434 14.26

10200

1182

12.30

1216

12.72

1251

13.12

1288

13.52

1327

13.91

1367 14.29

1410 14.67

1455 15.05

10600

1204

13.13

1238

13.55

1273

13.95

1310

14.35

1349

14.74

1389 15.12

1432 15.50

1477 15.88

11000

1226

14.00

1260

14.41

1296

14.82

1332

15.22

1371

15.60

1412 15.99

1454 16.36

1499 16.74

11400

1249

14.90

1283

15.32

1318

15.72

1355

16.12

1394

16.51

1434 16.89

-

-

-

-

11800

1272

15.84

1306

16.26

1342

16.66

1379

17.06

-

-

-

-

-

-

-

-

12200

1296

16.82

1330

17.23

-

-

-

-

-

-

-

-

-

-

-

-

12600

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

High Static 15 HP & Field Supplied Drive

 

1.Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.

2.See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.

3.kW = BHP x 0.82.

Johnson Controls Unitary Products

61

Image 61
Contents Description ZJ/ZR ShownTable of Contents ZJ shown Component LocationTon Sunline Magnum Model Number Nomenclature NomenclatureStandard Features Features and BenefitsBalanced Heating Factory Installed Options For 5-hp motor applications Control Options Field Installed AccessoriesIndoor Evaporator Fan Assembly Guide SpecificationsGeneral DescriptionRefrigerant Components Outdoor Condenser Fan AssemblyUnit Controls Gas Heating Section ZJ/ZR/ZF***N ModelsOther Pre-engineered Accessories Available Unit Operating CharacteristicsElectric Heating ZJ/ZR/ZF***C/E Models Electrical RequirementsNormal Mode Reheat Mode Sequence Of OperationAlternate Mode Reheat Controls Part Reheat Control BoardRHB ZJ180-300 Physical Data Physical DataFilters ZR180-300 Physical Data No. speeds Number of motors Motor HP each AFUE% ZF180-300 Physical DataMin ZJ/ZR/ZF180-300 Unit LimitationsZJ180-300 Cooling Capacities Capacity PerformanceZJ180 15 Ton 115F 125F ZJ210 17.5 Ton ZJ210 17.5 Ton ZJ240 20 Ton ZJ240 20 Ton ZJ300 25 Ton ZJ300 25 Ton ZR180 15 Ton ZR180-300 Cooling and Reheat CapacitiesZR180 15 Ton 35F 45F ZR180 15 Ton Alternate Reheat ModeSensible Capacity MBh ZR240 20 Ton 115F 125F ZR240 20 Ton Alternate Reheat Mode 75F 85F ZR300 25 Ton 115F 125F ZR300 25 Ton Alternate Reheat Mode 75F 85F ZF180 15 Ton ZF180-300 Cooling Capacities115F 125F ZF210 17.5 Ton ZF210 17.5 Ton ZF240 20 Ton ZF240 20 Ton ZF300 25 Ton ZF300 25 Ton ZJ180-300 Side Duct Application Airflow PerformanceZJ180 15 Ton Side Duct ZJ210 17.5 Ton Side DuctZJ240 20 Ton Side Duct ZJ300 25 Ton Side Duct ZJ180 15 Ton Bottom Duct ZJ180-300 Bottom Duct ApplicationZJ210 17.5 Ton Bottom Duct ZJ240 20 Ton Bottom Duct ZJ300 25 Ton Bottom Duct ZR180 15 Ton Side Duct ZR180-300 Side Duct ApplicationZR240 20 Ton Side Duct ZR300 25 Ton Side Duct ZR180 15 Ton Bottom Duct ZR180-300 Bottom Duct ApplicationZR240 20 Ton Bottom Duct ZR300 25 Ton Bottom Duct ZF180 15 Ton Side Duct ZF180-300 Side Duct ApplicationZF210 17.5 Ton Side Duct ZF240 20 Ton Side Duct ZF300 25 Ton Side Duct ZF180 15 Ton Bottom Duct ZF180-300 Bottom Duct ApplicationZF210 17.5 Ton Bottom Duct ZF240 20 Ton Bottom Duct ZF300 25 Ton Bottom Duct Additional Static Resistance RPM SelectionDrive Selection Air Temperature ºF Gas Heat Minimum Supply Air Altitude/Temperature Correction FactorsFactor CorrectionPower Exhaust Specifications Indoor Blower SpecificationsElectric Heat Minimum Supply Air ZJ/ZR/ZF Outdoor Sound Power Levels ZJ/ZR/ZF Indoor Sound Power LevelsSound Performance Electric Heat MultipliersElectrical Data ZJ180-300 Standard Drive Without Powered Convenience OutletZJ180 MCA Model Stages Amps ZJ180-300 Standard Drive With Powered Convenience OutletZJ180-300 Standard Drive With Powered Convenience Outlet Conv YTG-J-0910 ZJ180-300 High Static Drive With Powered Convenience Outlet ZJ180-300 High Static Drive With Powered Convenience Outlet ZJ300 Low Static Drive With Powered Convenience Outlet ZJ300 Low Static Drive Without Powered Convenience OutletZR180 ZR180-300 Standard Drive Without Powered Convenience OutletZR180-300 Standard Drive With Powered Convenience Outlet YTG-J-0910 ZR180-300 High Static Drive With Powered Convenience Outlet ZR300 Low Static Drive With Powered Convenience Outlet ZR300 Low Static Drive Without Powered Convenience OutletZF180 ZF180-300 Standard Drive Without Powered Convenience OutletPwr Max Fuse Motors ZF180-300 Standard Drive With Powered Convenience Outlet ZF180-300 Standard Drive With Powered Convenience Outlet ZF180-300 Hi Static Drive Without Powered Convenience Outlet ZF180-300 Hi Static Drive Without Powered Convenience Outlet ZF180-300 Hi Static Drive With Powered Convenience Outlet ZF180-300 Hi Static Drive With Powered Convenience Outlet ZF180-300 Low Static Drive With Powered Convenience Outlet ZJ180-300 Typical Control Diagram ZJ/ZR/ZF180-300 Wiring DiagramsOCC Terminal Block ZR180-300 Typical Control DiagramOCC ZF180-300 Typical Control DiagramZJ/ZR/ZF180-300 Unit Weights Weights and DimensionsZF Unit 4 Point Load Weight ZF Unit 6 Point Load Weight Supply Fan VFD Weights, in Lbs ZJ/ZR/ZF180-300 Unit Accessory WeightsZJ/ZR Unit Dimensions Front View Unit DimensionsUtilities Entry Front View For bottom duct applications ZJ/ZR/ZF Unit Dimensions Rear ViewFor side duct applications ZJ/ZR/ZF180-300 Unit Clearances ZJ/ZR/ZF Unit Dimensions Rain HoodZJ/ZR180-300, ZF210-300 Roof Curb Unit Accessory DimensionsZF180 Roof Curb ZJ/ZR/ZF180-300 Typical Installation Johnson Controls Unitary Products York Drive Norman, OK

251934-YTG-J-0910 specifications

York 251934-YTG-J-0910 is an innovative climate control system designed for both residential and commercial applications. This unit stands out for its advanced engineering, eco-friendly technologies, and user-centric features. With a focus on efficiency and sustainability, the York 251934-YTG-J-0910 offers a powerful solution for maintaining optimal indoor climates.

One of the main features of the York 251934-YTG-J-0910 is its high-efficiency operation. The unit boasts impressive Seasonal Energy Efficiency Ratio (SEER) and Heating Seasonal Performance Factor (HSPF) ratings, which indicate its ability to provide significant energy savings compared to traditional systems. The use of variable speed technology further enhances its efficiency, allowing the system to adjust its output based on real-time demand, leading to quieter operation and reduced energy consumption.

The York 251934-YTG-J-0910 incorporates cutting-edge inverter technology, which enables smooth transitions between different performance levels. This ensures consistent comfort while minimizing energy usage, making it an ideal choice for eco-conscious consumers. The unit also includes advanced inverter-driven compressors that enable faster cooling and heating capabilities, providing rapid comfort during extreme temperature conditions.

In terms of environmental impact, the York 251934-YTG-J-0910 is designed to operate with lowGlobal Warming Potential (GWP) refrigerants. This not only contributes to reduced greenhouse gas emissions but also aligns with global sustainability efforts. The unit is compliant with various environmental regulations, making it a responsible choice for climate-conscious users.

Another notable characteristic of this system is its intuitive smart controls. The York 251934-YTG-J-0910 is compatible with Wi-Fi-enabled thermostats and smart home systems, allowing users to monitor and adjust their indoor climate remotely. This level of connectivity offers convenience, energy management, and peace of mind.

Durability and reliability are also paramount to the York brand, and the 251934-YTG-J-0910 reflects this commitment. The unit features a robust construction with corrosion-resistant materials, ensuring longevity even in the harshest environments. Comprehensive warranties accompany the product, underlining the manufacturer’s confidence in its performance and durability.

In summary, the York 251934-YTG-J-0910 combines high efficiency, advanced technology, environmental responsibility, and user-friendly features, positioning it as a top contender in the climate control market. With its commitment to comfort and sustainability, it appeals to both residential and commercial users looking for reliable and efficient climate management solutions.