York 251934-YTG-J-0910 manual Control Options, Field Installed Accessories

Page 8

251934-YTG-J-0910

Control Options

BAS - Building Automation System Controls (available on two-system cooling product only).

Simplicity™ INTELLI-Comfort™ Control - The York® Simplicity™ INTELLI-CO2sensor to perform Differential Demand Ventilation. It uses a Patented Comfort Ventilation algorithm to provide comfortable ventilation air temperature. The patented economizer-loading algorithm will protect the equipment when harsh operating conditions exist. Humidity in the occupied space or return duct can be monitored and controlled via humidity sensors and the on-board connection for hot gas re-heat system. It uses the INTELLI-Start™ algorithm to maximize energy savings by recovering the building from the Unoccupied Setpoints to the Occupied Setpoints just in time for the Occupied Time Period to begin. The Simplicity™ INTELLI-Comfort™ balances space temperature, ventilation air temperature, CO2 and humidity for ultimate comfort.

Simplicity™ INTELLI-Comfort™ with Simplicity™LINC Control - The York® Simplicity™ INTELLI-Comfort™ with Simplicity™LINC control is factory installed. It includes all the features of the INTELLI-Comfort™ control with an additional control to translate communications from MODBUS to the BACnet MSTP protocol.

Novar® BAS Control - The Novar® building automation system controller is factory installed. Incudes supply air sensor, return air sensor, dirty filter indicator switch, and air proving switch.

Johnson Controls BAS Control - The Johnson Control YK-UNT-1126 building automation system controller is factory installed. Includes supply air sensor, return air sensor, dirty filter indicator switch, and air proving switch.

CPC BAS Control - The Computer Process Controls Model 810-3060 ARTC Advanced Rooftop building automation system controller is factory installed. Includes supply air sensor, return air sensor, dirty filter indicator switch and air proving switch.

Honeywell BAS Control - The Honeywell W7750C building automation system controller is factory installed. Includes air supply sensor, return air sensor, dirty filter indicator switch, and air proving switch.

Field Installed Accessories

YORK® offers several equipment accessories for field installation, for the ZJ/ZR/ZF Series.

Single Input Electronic Enthalpy Economizers - Includes a slide-in /plug-in damper assembly with fully modulating spring-return motor actuator capable of introducing up to 100% outdoor air with nominal 1% leakage type dampers.

The enthalpy system contains one sensor that monitors the outdoor air and determines when the air is cool enough and dry enough to provide free cooling.

The rainhood is painted to match the basic unit and must be field-assembled before installing.

Motorized Outdoor Air Intake Damper - Includes a slide-in /plug-in damper assembly with a 2-position, spring return motor actuator which opens to some pre-set position whenever the supply air blower is operating and will drive fully closed when the blower unit shuts down.

The rain hood is painted to match the basic unit and must be field assembled before installing.

Roof Curbs - Fourteen-inch high roof curbs provide a water-tight seal between the unit and the finished roof.

These full perimeter curbs meet the requirements of the National Roofing Contractors Association (NRCA) and are shipped knocked-down for field assembly.

They're designed to fit inside the base rails of the unit and include both a wood nailing strip and duct hanger supports.

High Altitude Natural Gas - Burner orifices and pilot orifices are provided for proper furnace operation at altitudes up to 6,000 feet.

Propane - Burner orifices, pilot orifices and gas valve parts are provided to convert a natural gas furnace to propane.

High Altitude Propane - Burner orifices and pilot orifices are provided for proper furnace operation at altitudes up to 6,000 feet. This accessory supplements the basic propane conversion kit.

Side Duct Flanges - One-inch flanges replace the supply and return air panels on the rear of the unit to accommodate horizontal duct connections. These flanges can also be used individually for bottom supply / horizontal return or horizontal supply/bottom return. They cannot be used on units with power exhaust.

Barometric Relief Damper - This damper accessory can be used to relieve internal building air pressure on units with an economizer without power exhaust. This accessory includes a rain hood, a bird screen and a fully assembled damper. With bottom duct connections, the damper should be mounted over the opening in the return air panel. With horizontal ductwork, the accessory should be mounted on the return air duct.

High Static Drive - May include a belt, blower pulley, motor pulley or a motor change to enhance blower performance.

Enthalpy Accessory Control Kit - This kit contains the required components to convert a single enthalpy economizer to dual enthalpy.

Burglar Bars - Mount in the supply and return openings to prevent entry into the duct work.

Flue Exhaust Extension Kit - In locations with wind or weather conditions which may interfere with proper exhausting of furnace combustion products, this kit can be installed to prevent the flue exhaust from entering nearby fresh air intakes.

Wood Skid - Allows unit to be handled with 90" forks.

CO2 Sensor - Senses CO2 levels and automatically overrides the economizer when levels rise above the present limits.

Coil Guard - Customers can purchase a coil guard kit to protect the condenser coil from damage. This is not a hail guard kit.

8

Johnson Controls Unitary Products

Image 8
Contents ZJ/ZR Shown DescriptionTable of Contents Component Location ZJ shownNomenclature Ton Sunline Magnum Model Number NomenclatureBalanced Heating Features and BenefitsStandard Features Factory Installed Options For 5-hp motor applications Field Installed Accessories Control OptionsGuide Specifications Indoor Evaporator Fan AssemblyGeneral DescriptionOutdoor Condenser Fan Assembly Refrigerant ComponentsUnit Controls Gas Heating Section ZJ/ZR/ZF***N ModelsUnit Operating Characteristics Other Pre-engineered Accessories AvailableElectric Heating ZJ/ZR/ZF***C/E Models Electrical RequirementsAlternate Mode Reheat Mode Sequence Of OperationNormal Mode Reheat Control Board Reheat Controls PartRHB Physical Data ZJ180-300 Physical DataFilters ZR180-300 Physical Data No. speeds Number of motors Motor HP each ZF180-300 Physical Data AFUE%ZJ/ZR/ZF180-300 Unit Limitations MinZJ180 15 Ton Capacity PerformanceZJ180-300 Cooling Capacities 115F 125F ZJ210 17.5 Ton ZJ210 17.5 Ton ZJ240 20 Ton ZJ240 20 Ton ZJ300 25 Ton ZJ300 25 Ton ZR180-300 Cooling and Reheat Capacities ZR180 15 TonZR180 15 Ton ZR180 15 Ton Alternate Reheat Mode 35F 45FSensible Capacity MBh ZR240 20 Ton 115F 125F ZR240 20 Ton Alternate Reheat Mode 75F 85F ZR300 25 Ton 115F 125F ZR300 25 Ton Alternate Reheat Mode 75F 85F ZF180-300 Cooling Capacities ZF180 15 Ton115F 125F ZF210 17.5 Ton ZF210 17.5 Ton ZF240 20 Ton ZF240 20 Ton ZF300 25 Ton ZF300 25 Ton Airflow Performance ZJ180-300 Side Duct ApplicationZJ180 15 Ton Side Duct ZJ210 17.5 Ton Side DuctZJ240 20 Ton Side Duct ZJ300 25 Ton Side Duct ZJ210 17.5 Ton Bottom Duct ZJ180-300 Bottom Duct ApplicationZJ180 15 Ton Bottom Duct ZJ240 20 Ton Bottom Duct ZJ300 25 Ton Bottom Duct ZR240 20 Ton Side Duct ZR180-300 Side Duct ApplicationZR180 15 Ton Side Duct ZR300 25 Ton Side Duct ZR240 20 Ton Bottom Duct ZR180-300 Bottom Duct ApplicationZR180 15 Ton Bottom Duct ZR300 25 Ton Bottom Duct ZF210 17.5 Ton Side Duct ZF180-300 Side Duct ApplicationZF180 15 Ton Side Duct ZF240 20 Ton Side Duct ZF300 25 Ton Side Duct ZF210 17.5 Ton Bottom Duct ZF180-300 Bottom Duct ApplicationZF180 15 Ton Bottom Duct ZF240 20 Ton Bottom Duct ZF300 25 Ton Bottom Duct RPM Selection Additional Static ResistanceDrive Selection Altitude/Temperature Correction Factors Air Temperature ºF Gas Heat Minimum Supply AirFactor CorrectionElectric Heat Minimum Supply Air Indoor Blower SpecificationsPower Exhaust Specifications ZJ/ZR/ZF Indoor Sound Power Levels ZJ/ZR/ZF Outdoor Sound Power LevelsSound Performance Electric Heat MultipliersZJ180 ZJ180-300 Standard Drive Without Powered Convenience OutletElectrical Data MCA ZJ180-300 Standard Drive With Powered Convenience Outlet Model Stages AmpsZJ180-300 Standard Drive With Powered Convenience Outlet Conv YTG-J-0910 ZJ180-300 High Static Drive With Powered Convenience Outlet ZJ180-300 High Static Drive With Powered Convenience Outlet ZJ300 Low Static Drive Without Powered Convenience Outlet ZJ300 Low Static Drive With Powered Convenience OutletZR180-300 Standard Drive Without Powered Convenience Outlet ZR180ZR180-300 Standard Drive With Powered Convenience Outlet YTG-J-0910 ZR180-300 High Static Drive With Powered Convenience Outlet ZR300 Low Static Drive Without Powered Convenience Outlet ZR300 Low Static Drive With Powered Convenience OutletZF180-300 Standard Drive Without Powered Convenience Outlet ZF180Pwr Max Fuse Motors ZF180-300 Standard Drive With Powered Convenience Outlet ZF180-300 Standard Drive With Powered Convenience Outlet ZF180-300 Hi Static Drive Without Powered Convenience Outlet ZF180-300 Hi Static Drive Without Powered Convenience Outlet ZF180-300 Hi Static Drive With Powered Convenience Outlet ZF180-300 Hi Static Drive With Powered Convenience Outlet ZF180-300 Low Static Drive With Powered Convenience Outlet ZJ/ZR/ZF180-300 Wiring Diagrams ZJ180-300 Typical Control DiagramZR180-300 Typical Control Diagram OCC Terminal BlockZF180-300 Typical Control Diagram OCCZF Unit 4 Point Load Weight ZF Unit 6 Point Load Weight Weights and DimensionsZJ/ZR/ZF180-300 Unit Weights ZJ/ZR/ZF180-300 Unit Accessory Weights Supply Fan VFD Weights, in LbsUtilities Entry Unit DimensionsZJ/ZR Unit Dimensions Front View Front View For side duct applications ZJ/ZR/ZF Unit Dimensions Rear ViewFor bottom duct applications ZJ/ZR/ZF Unit Dimensions Rain Hood ZJ/ZR/ZF180-300 Unit ClearancesZF180 Roof Curb Unit Accessory DimensionsZJ/ZR180-300, ZF210-300 Roof Curb ZJ/ZR/ZF180-300 Typical Installation Johnson Controls Unitary Products York Drive Norman, OK

251934-YTG-J-0910 specifications

York 251934-YTG-J-0910 is an innovative climate control system designed for both residential and commercial applications. This unit stands out for its advanced engineering, eco-friendly technologies, and user-centric features. With a focus on efficiency and sustainability, the York 251934-YTG-J-0910 offers a powerful solution for maintaining optimal indoor climates.

One of the main features of the York 251934-YTG-J-0910 is its high-efficiency operation. The unit boasts impressive Seasonal Energy Efficiency Ratio (SEER) and Heating Seasonal Performance Factor (HSPF) ratings, which indicate its ability to provide significant energy savings compared to traditional systems. The use of variable speed technology further enhances its efficiency, allowing the system to adjust its output based on real-time demand, leading to quieter operation and reduced energy consumption.

The York 251934-YTG-J-0910 incorporates cutting-edge inverter technology, which enables smooth transitions between different performance levels. This ensures consistent comfort while minimizing energy usage, making it an ideal choice for eco-conscious consumers. The unit also includes advanced inverter-driven compressors that enable faster cooling and heating capabilities, providing rapid comfort during extreme temperature conditions.

In terms of environmental impact, the York 251934-YTG-J-0910 is designed to operate with lowGlobal Warming Potential (GWP) refrigerants. This not only contributes to reduced greenhouse gas emissions but also aligns with global sustainability efforts. The unit is compliant with various environmental regulations, making it a responsible choice for climate-conscious users.

Another notable characteristic of this system is its intuitive smart controls. The York 251934-YTG-J-0910 is compatible with Wi-Fi-enabled thermostats and smart home systems, allowing users to monitor and adjust their indoor climate remotely. This level of connectivity offers convenience, energy management, and peace of mind.

Durability and reliability are also paramount to the York brand, and the 251934-YTG-J-0910 reflects this commitment. The unit features a robust construction with corrosion-resistant materials, ensuring longevity even in the harshest environments. Comprehensive warranties accompany the product, underlining the manufacturer’s confidence in its performance and durability.

In summary, the York 251934-YTG-J-0910 combines high efficiency, advanced technology, environmental responsibility, and user-friendly features, positioning it as a top contender in the climate control market. With its commitment to comfort and sustainability, it appeals to both residential and commercial users looking for reliable and efficient climate management solutions.