York 251934-YTG-J-0910 manual ZJ300 Low Static Drive Without Powered Convenience Outlet

Page 78

251934-YTG-J-0910

ZJ300 - Low Static Drive Without Powered Convenience Outlet

 

 

Compressors

OD Fan

Supply

Pwr

 

 

 

 

 

 

Max Fuse2/

Size

 

Motors

Blower

Conv

 

Electric Heat Option

 

MCA1

Breaker3

Volt

 

(each)

 

 

 

(Tons)

 

 

(each)

Motor

Outlet

 

 

 

 

 

(Amps)

Size

 

 

 

 

 

 

 

 

 

 

 

 

RLA

LRA

 

MCC

FLA

FLA

FLA

Model

kW

Stages

 

Amps

 

(Amps)

 

 

 

 

 

 

 

 

 

None

-

-

 

-

132.6

150

 

 

 

 

 

 

 

 

 

E18

13.5

1

 

37.5

132.6

150

 

208-3-60

23.0

160

 

31.5

3.7

20.0

0.0

E36

27.0

2

 

74.9

132.6

150

 

 

 

 

 

 

 

 

 

E54

40.6

2

 

112.7

165.9

175

 

 

 

 

 

 

 

 

 

E72

54.1

2

 

150.2

175.2

200

 

 

 

 

 

 

 

 

 

None

-

-

 

-

132.6

150

 

 

 

 

 

 

 

 

 

E18

18.0

1

 

43.3

132.6

150

 

230-3-60

23.0

160

 

31.5

3.7

20.0

0.0

E36

36.0

2

 

86.6

133.3

150

 

 

 

 

 

 

 

 

 

E54

54.0

2

 

129.9

154.9

175

300

 

 

 

 

 

 

 

 

E72

72.0

2

 

173.2

198.2

225

(25)

 

 

 

 

 

 

 

 

None

-

-

 

-

69.5

80

 

 

 

 

 

 

 

 

 

E18

18.0

1

 

21.7

69.5

80

 

460-3-60

12.2

87

 

17.1

1.9

10.0

0.0

E36

36.0

2

 

43.3

69.5

80

 

 

 

 

 

 

 

 

 

E54

54.0

2

 

65.0

77.5

90

 

 

 

 

 

 

 

 

 

E72

72.0

2

 

86.6

99.1

110

 

 

 

 

 

 

 

 

 

None

-

-

 

-

51.2

60

 

 

 

 

 

 

 

 

 

E18

18.0

1

 

17.3

51.2

60

 

575-3-60

8.7

62

 

13.5

1.5

8.2

0.0

E36

36.0

2

 

34.6

53.6

60

 

 

 

 

 

 

 

 

 

E54

54.0

2

 

52.0

62.2

70

 

 

 

 

 

 

 

 

 

E72

72.0

2

 

69.3

79.5

90

1.Minimum Circuit Ampacity.

2.Dual Element, Time Delay Type.

3.HACR type per NEC.

ZJ300 - Low Static Drive With Powered Convenience Outlet

 

 

Compressors

OD Fan

Supply

Pwr

 

 

 

 

 

 

Max Fuse2/

Size

 

Motors

Blower

Conv

 

Electric Heat Option

 

MCA1

Breaker3

Volt

 

(each)

 

 

 

(Tons)

 

 

(each)

Motor

Outlet

 

 

 

 

 

(Amps)

Size

 

 

 

 

 

 

 

 

 

 

 

 

RLA

LRA

 

MCC

FLA

FLA

FLA

Model

kW

Stages

 

Amps

 

(Amps)

 

 

 

 

 

 

 

 

 

None

-

-

 

-

142.6

150

 

 

 

 

 

 

 

 

 

E18

13.5

1

 

37.5

142.6

150

 

208-3-60

23.0

160

 

31.5

3.7

20.0

10.0

E36

27.0

2

 

74.9

142.6

150

 

 

 

 

 

 

 

 

 

E54

40.6

2

 

112.7

178.4

200

 

 

 

 

 

 

 

 

 

E72

54.1

2

 

150.2

187.7

200

 

 

 

 

 

 

 

 

 

None

-

-

 

-

142.6

150

 

 

 

 

 

 

 

 

 

E18

18.0

1

 

43.3

142.6

150

 

230-3-60

23.0

160

 

31.5

3.7

20.0

10.0

E36

36.0

2

 

86.6

145.8

150

 

 

 

 

 

 

 

 

 

E54

54.0

2

 

129.9

167.4

175

300

 

 

 

 

 

 

 

 

E72

72.0

2

 

173.2

210.7

225

(25)

 

 

 

 

 

 

 

 

None

-

-

 

-

74.5

80

 

 

 

 

 

 

 

 

 

E18

18.0

1

 

21.7

74.5

80

 

460-3-60

12.2

87

 

17.1

1.9

10.0

5.0

E36

36.0

2

 

43.3

74.5

80

 

 

 

 

 

 

 

 

 

E54

54.0

2

 

65.0

83.7

90

 

 

 

 

 

 

 

 

 

E72

72.0

2

 

86.6

105.4

110

 

 

 

 

 

 

 

 

 

None

-

-

 

-

55.2

60

 

 

 

 

 

 

 

 

 

E18

18.0

1

 

17.3

55.2

60

 

575-3-60

8.7

62

 

13.5

1.5

8.2

4.0

E36

36.0

2

 

34.6

58.6

60

 

 

 

 

 

 

 

 

 

E54

54.0

2

 

52.0

67.2

70

 

 

 

 

 

 

 

 

 

E72

72.0

2

 

69.3

84.5

90

1.Minimum Circuit Ampacity.

2.Dual Element, Time Delay Type.

3.HACR type per NEC.

78

Johnson Controls Unitary Products

Image 78 Contents
ZJ/ZR Shown DescriptionTable of Contents Component Location ZJ shownNomenclature Ton Sunline Magnum Model Number NomenclatureFeatures and Benefits Standard FeaturesBalanced Heating Factory Installed Options For 5-hp motor applications Field Installed Accessories Control OptionsGeneral Guide SpecificationsIndoor Evaporator Fan Assembly DescriptionUnit Controls Outdoor Condenser Fan AssemblyRefrigerant Components Gas Heating Section ZJ/ZR/ZF***N ModelsElectric Heating ZJ/ZR/ZF***C/E Models Unit Operating CharacteristicsOther Pre-engineered Accessories Available Electrical RequirementsReheat Mode Sequence Of Operation Normal ModeAlternate Mode Reheat Control Board Reheat Controls PartRHB Physical Data ZJ180-300 Physical DataFilters ZR180-300 Physical Data No. speeds Number of motors Motor HP each ZF180-300 Physical Data AFUE%ZJ/ZR/ZF180-300 Unit Limitations MinCapacity Performance ZJ180-300 Cooling CapacitiesZJ180 15 Ton 115F 125F ZJ210 17.5 Ton ZJ210 17.5 Ton ZJ240 20 Ton ZJ240 20 Ton ZJ300 25 Ton ZJ300 25 Ton ZR180-300 Cooling and Reheat Capacities ZR180 15 TonZR180 15 Ton ZR180 15 Ton Alternate Reheat Mode 35F 45FSensible Capacity MBh ZR240 20 Ton 115F 125F ZR240 20 Ton Alternate Reheat Mode 75F 85F ZR300 25 Ton 115F 125F ZR300 25 Ton Alternate Reheat Mode 75F 85F ZF180-300 Cooling Capacities ZF180 15 Ton115F 125F ZF210 17.5 Ton ZF210 17.5 Ton ZF240 20 Ton ZF240 20 Ton ZF300 25 Ton ZF300 25 Ton ZJ180 15 Ton Side Duct Airflow PerformanceZJ180-300 Side Duct Application ZJ210 17.5 Ton Side DuctZJ240 20 Ton Side Duct ZJ300 25 Ton Side Duct ZJ180-300 Bottom Duct Application ZJ180 15 Ton Bottom DuctZJ210 17.5 Ton Bottom Duct ZJ240 20 Ton Bottom Duct ZJ300 25 Ton Bottom Duct ZR180-300 Side Duct Application ZR180 15 Ton Side DuctZR240 20 Ton Side Duct ZR300 25 Ton Side Duct ZR180-300 Bottom Duct Application ZR180 15 Ton Bottom DuctZR240 20 Ton Bottom Duct ZR300 25 Ton Bottom Duct ZF180-300 Side Duct Application ZF180 15 Ton Side DuctZF210 17.5 Ton Side Duct ZF240 20 Ton Side Duct ZF300 25 Ton Side Duct ZF180-300 Bottom Duct Application ZF180 15 Ton Bottom DuctZF210 17.5 Ton Bottom Duct ZF240 20 Ton Bottom Duct ZF300 25 Ton Bottom Duct RPM Selection Additional Static ResistanceDrive Selection Factor Altitude/Temperature Correction FactorsAir Temperature ºF Gas Heat Minimum Supply Air CorrectionIndoor Blower Specifications Power Exhaust SpecificationsElectric Heat Minimum Supply Air Sound Performance ZJ/ZR/ZF Indoor Sound Power LevelsZJ/ZR/ZF Outdoor Sound Power Levels Electric Heat MultipliersZJ180-300 Standard Drive Without Powered Convenience Outlet Electrical DataZJ180 MCA ZJ180-300 Standard Drive With Powered Convenience Outlet Model Stages AmpsZJ180-300 Standard Drive With Powered Convenience Outlet Conv YTG-J-0910 ZJ180-300 High Static Drive With Powered Convenience Outlet ZJ180-300 High Static Drive With Powered Convenience Outlet ZJ300 Low Static Drive Without Powered Convenience Outlet ZJ300 Low Static Drive With Powered Convenience OutletZR180-300 Standard Drive Without Powered Convenience Outlet ZR180ZR180-300 Standard Drive With Powered Convenience Outlet YTG-J-0910 ZR180-300 High Static Drive With Powered Convenience Outlet ZR300 Low Static Drive Without Powered Convenience Outlet ZR300 Low Static Drive With Powered Convenience OutletZF180-300 Standard Drive Without Powered Convenience Outlet ZF180Pwr Max Fuse Motors ZF180-300 Standard Drive With Powered Convenience Outlet ZF180-300 Standard Drive With Powered Convenience Outlet ZF180-300 Hi Static Drive Without Powered Convenience Outlet ZF180-300 Hi Static Drive Without Powered Convenience Outlet ZF180-300 Hi Static Drive With Powered Convenience Outlet ZF180-300 Hi Static Drive With Powered Convenience Outlet ZF180-300 Low Static Drive With Powered Convenience Outlet ZJ/ZR/ZF180-300 Wiring Diagrams ZJ180-300 Typical Control DiagramZR180-300 Typical Control Diagram OCC Terminal BlockZF180-300 Typical Control Diagram OCCWeights and Dimensions ZJ/ZR/ZF180-300 Unit WeightsZF Unit 4 Point Load Weight ZF Unit 6 Point Load Weight ZJ/ZR/ZF180-300 Unit Accessory Weights Supply Fan VFD Weights, in LbsUnit Dimensions ZJ/ZR Unit Dimensions Front ViewUtilities Entry Front View ZJ/ZR/ZF Unit Dimensions Rear View For bottom duct applicationsFor side duct applications ZJ/ZR/ZF Unit Dimensions Rain Hood ZJ/ZR/ZF180-300 Unit ClearancesUnit Accessory Dimensions ZJ/ZR180-300, ZF210-300 Roof CurbZF180 Roof Curb ZJ/ZR/ZF180-300 Typical Installation Johnson Controls Unitary Products York Drive Norman, OK