HP A.06.11 manual Autochanger robotics device and identify it as Picker

Page 25

5.For a standalone (DDS) device, add:

• Path for device and identify it as PSEUDO:

Tape drive device (always on path address ending with 0), set ID and mode as AUTOREPLY:

IO>ADEV LDEV=30 PATH=52.3.0 ID=HPC1533A MODE=AUTOREPLY

Autochanger (robotics) device and identify it as PICKER:

IO>ADEV LDEV=31 PATH=52.3.1 ID=PICKER

The MAPPER utility lists the path number (for example, PATH=52.3) and ID for the device (use the first word from Component Name, for example ID=HPC1533A).

The LDEV number is any free number from 1-255. You can check already used numbers by listing all devices with SYSGEN, IO subsystem, or the showdev command:

:SYSGEN

SYSGEN>IO

IO>LDEV

:SHOWDEV

The path address for autochanger is usually the path address for tape +1.

NOTE:

For SCSI devices, use PSEUDO as the device identifier.

MPE/iX system user guide

25

Image 25
Contents HP Data Protector A.06.11 MPE/iX system user guide Page Contents Index Figures Tables Part number Guide edition Product Edition historyPublication history Documentation set Intended audienceGuides Other documents and online Help provide related informationHP Data Protector disaster recovery guide HP Data Protector integration guide for HP Reporter This guide fulfills a similar function for Media Operations Online HelpAbbreviations Documentation mapGuide Abbreviation Guide MapIntegrations Integration Guide Document conventions Document conventions and symbolsConvention Element Provides additional information Data Protector graphical user interfaceProvides helpful hints and shortcuts Data Protector graphical user interface General information HP technical supportHP websites Subscription serviceDocumentation feedback For additional information, see the following HP websitesIntroduction Configuring the integrationIntegration concepts PrerequisitesConfiguring standalone devices Configuring devicesBefore you begin Connect a device to the systemO configuration standalone device Run the Sysgen utility, IO subsystem Ioadev LDEV=31 PATH=52.3.1 ID=PICKER Autochanger robotics device and identify it as PickerKeep the new configuration and exit Sysgen Configuring Scsi tape librariesCreate a device link file using mknod At the ISL prompt, enter O configuration Scsi tape libraryMODE=AUTOREPLY Paths and devices for tapesTurboSTORE/iX supports two backup types BackupBackup types List of backup variables User-definable backup variablesVariable Value Description Setting Backup Variables Specifying backup options TurboSTORE/iX backup options Full system backupClick Add to add the new variable to the list Creating SLT RestoreCreating Store Tapes To create a SLT, runSetting Restore Variables User-definable restore variablesList of restore variables Click OK to apply the settings TurboSTORE/iX restore optionsDisaster recovery Pre- and post-exec commandsShell script can contain commands for job streaming ExampleRecovery Procedure Supported CLI commandsData Protector A.06.11 supports the omnib command Backup and restore of MPE/iX database Example 1. TurboSTORE/iX log files with Online TurboSTORE/iX log filesUDC files and environment variables To create a UDC file, enter the following in command promptUDC files Example 2. TurboSTORE/iX log files with ONLINE=STARTExample OB2SET fileTo activate the UDC file enter Index