HP A.06.11 User-definable restore variables, Setting Restore Variables, List of restore variables

Page 35

User-definable restore variables

Set user-definable variables (a variable name and its value) to enable flexible operation of the Data Protector MPE/iX integration.

Table 5 on page 35 lists restore variables and their values.

Table 5 List of restore variables

 

Variable

Value

Description

DIRECTORY

none (default)

Restores the MPE system directory (volume

 

 

set configuration) information.

VOLSET

/volume_set_name

Performs the restore to target volume set, if

 

 

backed up volume set is different

 

 

(cross-volume set restore using options -as

 

 

or -into).

CREATE

NOHFS

Forces restore of MPE account or MPE group

 

 

instead of HFS directory.

User-definable options that depend on TurboSTORE/iX options are DIRECTORY and VOLSET. These options are mapped to the same TurboSTORE/iX options.

The option CREATE=NOHFS is not a TurboSTORE/iX option.

Setting Restore Variables

1.In the HP Data Protector Manager, switch to the Restore context.

2.In the Scoping Pane, under Restore Objects, expand the appropriate data type.

3.Expand the client system and then click the appropriate object.

4.In the Source Property page, select objects for restore.

5.Click the Options tab to open the Options Property page.

6.Click Advanced.

MPE/iX system user guide

35

Image 35
Contents HP Data Protector A.06.11 MPE/iX system user guide Page Contents Index Figures Tables Part number Guide edition Product Edition historyPublication history Other documents and online Help provide related information Intended audienceDocumentation set GuidesHP Data Protector disaster recovery guide HP Data Protector integration guide for HP Reporter This guide fulfills a similar function for Media Operations Online HelpGuide Documentation mapAbbreviations Abbreviation Guide MapIntegrations Integration Guide Convention Element Document conventions and symbolsDocument conventions Provides helpful hints and shortcuts Data Protector graphical user interfaceProvides additional information Data Protector graphical user interface General information HP technical supportFor additional information, see the following HP websites Subscription serviceHP websites Documentation feedbackPrerequisites Configuring the integrationIntroduction Integration conceptsConnect a device to the system Configuring devicesConfiguring standalone devices Before you beginO configuration standalone device Run the Sysgen utility, IO subsystem Ioadev LDEV=31 PATH=52.3.1 ID=PICKER Autochanger robotics device and identify it as PickerCreate a device link file using mknod Configuring Scsi tape librariesKeep the new configuration and exit Sysgen At the ISL prompt, enter O configuration Scsi tape libraryMODE=AUTOREPLY Paths and devices for tapesBackup types BackupTurboSTORE/iX supports two backup types Variable Value Description User-definable backup variablesList of backup variables Setting Backup Variables Specifying backup options Click Add to add the new variable to the list Full system backupTurboSTORE/iX backup options To create a SLT, run RestoreCreating SLT Creating Store TapesList of restore variables User-definable restore variablesSetting Restore Variables Click OK to apply the settings TurboSTORE/iX restore optionsExample Pre- and post-exec commandsDisaster recovery Shell script can contain commands for job streamingData Protector A.06.11 supports the omnib command Supported CLI commandsRecovery Procedure Backup and restore of MPE/iX database Example 1. TurboSTORE/iX log files with Online TurboSTORE/iX log filesExample 2. TurboSTORE/iX log files with ONLINE=START To create a UDC file, enter the following in command promptUDC files and environment variables UDC filesTo activate the UDC file enter OB2SET fileExample Index