6.Keep the new configuration and exit SYSGEN:
Enter Y for Purge old configuration (yes/no)?.
7.Create a device link file using mknod:
:mknod “/dev/dlt_picker c 0 30” :mknod “/dev/dlt_tape01 c 0 31” :mknod “/dev/dlt_tape02 c 0 32”
8.Restart the system to verify the changes.
After you connected and configured SCSI libraries, configure them for use with Data Protector. For detailed steps, see the online Help index: “configuring SCSI libraries”.
Backup
TurboSTORE/iX supports two backup types:
Table 3 Backup types
Online (option ONLINE) The files are closed for write access during backup.
The files are not required to be closed for write access during | |
ONLINE=START) | backup. |
MPE/iX system user guide | 29 |