Roberts Gorden CGTH-50, CGTH-30, CGTH-40 service manual Burner Makes Vibrating Noises While Running

Page 46

CGTH INSTALLATION, OPERATION AND SERVICE MANUAL

BURNER MAKES VIBRATING NOISES WHILE RUNNING

Possible Cause

Try this....

 

 

Motor Vibration

Ensure that the shipping screw has been removed from the control

 

housing door. See Page 17, Section 4.8.

 

 

Protective Grille metal fingers

Isolate the grille finger that is making the noise and cap it with a silicone

touch reflector

cap. See Page 20, Figure 12.

 

 

40

Image 46
Contents Gas-Fired, Low-Intensity Page 2005 Page Table of Figures Page Questions, Comments or Suggestions Before YOU Begin 1.1 Read This ManualRoberts-Gordon, LLC Safety Unpacking the Heater 2.3.1 Manpower RequirementsAbout the Heater Carton Contents of Heaters with Galvanized Venting Available as an accessory under kit part numbers Carton Contents of Heaters with Cox Geelen VentingHeater Assembly Manual Gas Shut-off ValveAvailable Accessories for Galvanized Vent Wall Venting Kit P/N 08032200 includes Components Identification Components Identification CGTH-Series byHeater Specifications Venting SpecificationsWhere Can the Heater Be Installed? Where Cant the Heater Be Installed?Electrical Service Requirements Gas Service Requirements 3.2.1 Gas TypeMeter and Service Planning 3.1 GeneralBalanced Flue Construction Venting Requirements 3.4.1 System RequirementsVenting Codes Public GaragesHazardous Locations Installation Tools InstallationSafety Equipment Installation MaterialsGeneral Venting Guidelines Required Safe Distances from Combustibles Model Inches Metric cmHang the Heater Remove Shipping Screw from Control Housing DoorNon-residential applications Horizontal Installation Typical InstallationDimension Model Minimum Maximum Heater Orientation13 45 Tilted Installation 45 Tilted InstallationGrille Installation for Select Models Only Silicone Cap InstallationGeneral Venting Requirements Venting InstallationInstall Galvanized Collar United States RequirementsGalvanized Horizontal Venting Bird Screen Installation Galvanized Horizontal Venting with an ElbowHorizontal Installation Top View Elbow Assembly Vent Assembly Overview Assembly OverviewHorizontal Installation Side View Cox Geelen Venting Cox Geelen Horizontal VentingFlue Collar and Adapter Part Number DescriptionVertical Venting Configurations Cox Geelen Vertical VentingVent Clamp Thermostat Placement Electrical Service InstallationHeater Rating 120V, 60 Hz, Single Phase, 1A System RequirementsThermostat Installation Rear View GAS Service Installation 7.1 Install Gas Supply Lines To Turn Off Gas To Heater TestingOperation 8.1 Operating Instructions Sequence of OperationCover Cap Regulator Screw Outlet Pressure Tap Possible Cause Try this Blower does not Come onIgniter does not Spark LP Gas Burner does not LightNatural Gas Manometer Reading Burner Cycles on and OFF TOO Quickly Housing door. See Page 17, Section Burner Makes Vibrating Noises While RunningMaintenance 10.1 Pre-Season Maintenance Wiring Diagrams 11.1 Connection Diagram Connection DiagramLadder Diagram Ladder Diagram Replacement Parts Illustrated Parts List for Burner Illustrated Parts ListReplacement Parts List for Burner Part Number Description CGTH-30 CGTH-40 CGTH-50 ROBERTS-GORDON will not PAY for Warranty is Void ifLimitations on Authority Representatives Page Owner Warranty Registration Card Page
Related manuals
Manual 30 pages 54.92 Kb

CGTH-40, CGTH-50, CGTH-30 specifications

Roberts Gordon is a renowned manufacturer known for its innovative heating solutions, particularly in the realm of infrared heaters. Among their product lineup, the CGTH series, which includes the CGTH-50, CGTH-40, and CGTH-30 models, exemplifies high-performance technology tailored specifically for industrial and commercial applications.

The CGTH series is designed for versatility and efficiency, offering advanced features that enhance the heating experience in various environments. One of the standout features of these heaters is their infrared technology, which provides targeted warmth, making them ideal for large, open spaces such as warehouses, factories, and sporting facilities. Infrared heaters work by directly heating objects and people in their path rather than the air, ensuring quicker warmth and greater energy efficiency.

Each model offers different heating capacities, with the CGTH-50 boasting a maximum output of 50,000 BTUs, the CGTH-40 providing up to 40,000 BTUs, and the CGTH-30 generating 30,000 BTUs. This variety allows users to choose a model that best fits their heating needs based on the size and requirements of their space.

The units are designed for easy installation, featuring a modular design that allows for both indoor and outdoor applications. Moreover, the heaters can be integrated with various control systems, including programmable thermostats and remote management, enhancing user convenience and optimizing energy usage.

A critical aspect of the CGTH series is its emphasis on durability and safety. Each model is crafted using high-quality materials that can withstand harsh conditions typically found in industrial settings. Additionally, they incorporate safety features such as over-temperature protection and robust mounting brackets, ensuring peace of mind during operation.

Another important characteristic of the CGTH series is their efficiency. By minimizing energy waste and targeting heat output precisely, these heaters can significantly lower energy costs, making them not only environmentally friendly but also economically advantageous for businesses.

In summary, the Roberts Gordon CGTH-50, CGTH-40, and CGTH-30 infrared heaters stand out for their innovative technology, energy efficiency, and reliability. Whether for large commercial spaces or industrial environments, these heating solutions are designed to provide the comfort and performance required for any operation. With their robust features and customizable options, they remain a top choice for effective heating solutions in diverse settings.