Roberts Gorden service manual CGTH-30 CGTH-40 CGTH-50

Page 52

CGTH INSTALLATION, OPERATION AND SERVICE MANUAL

12.2lllustrated Parts List for Tube and Reflector FIGURE 38: Tube and Reflector

F

G

H

E

 

 

D

 

I

C

 

B

 

Front Fixed Hanger (Ref)

K

 

 

 

 

J

 

 

A

12.3 Replacement Parts List for Tube & Reflector

 

 

 

 

Item

Part Number

Description

CGTH-30

CGTH-40

CGTH-50

 

 

 

 

 

 

 

A

08020001

Heat Exchanger Assembly (8') (2438 mm)

 

1

-

-

 

08021001

Heat Exchanger Assembly (11'6") (3505 mm)

-

1

1

 

 

 

 

 

 

 

B

94273914

Bolt Rolok® Hex HD 5/16-18 x 7/8

 

4

4

4

 

 

 

 

 

 

 

C

96411600

Lockwasher 5/16 Helical Spring

 

4

4

4

 

 

 

 

 

 

 

D

08061000

Support Plate

 

1

1

1

 

 

 

 

 

 

 

E

08070000

Burner Tube Gasket

 

1

1

1

 

 

 

 

 

 

 

F

-

Screw (#8 x 3/8" (10 mm)

 

4

4

4

 

 

 

 

 

 

 

G

08090000

Reflector (80") (2032 mm)

 

1

-

-

 

08090001

Reflector (120") (3048 mm)

 

 

1

1

 

 

 

 

 

 

 

H

02750800

End Cap

 

1

1

1

 

 

 

 

 

 

 

I

*91107720

U-Clips

 

4

4

4

 

 

 

 

 

 

 

J

08080000

Rear Reflector Hanger (Moveable)

 

1

1

1

 

 

 

 

 

 

 

K

08061000

Support Plate

 

-

1

1

 

08062000

Support U-bolt

 

2

2

2

 

 

 

 

 

 

 

(*)Part number shown is for reorder purposes and represents a package of 20 pieces.

46

Image 52
Contents Gas-Fired, Low-Intensity Page 2005 Page Table of Figures Page Questions, Comments or Suggestions Before YOU Begin 1.1 Read This ManualRoberts-Gordon, LLC Safety Unpacking the Heater 2.3.1 Manpower RequirementsAbout the Heater Carton Contents of Heaters with Galvanized Venting Carton Contents of Heaters with Cox Geelen Venting Heater AssemblyAvailable as an accessory under kit part numbers Manual Gas Shut-off ValveAvailable Accessories for Galvanized Vent Wall Venting Kit P/N 08032200 includes Components Identification Components Identification CGTH-Series byHeater Specifications Venting SpecificationsWhere Can the Heater Be Installed? Where Cant the Heater Be Installed?Gas Service Requirements 3.2.1 Gas Type Meter and ServiceElectrical Service Requirements Planning 3.1 GeneralVenting Requirements 3.4.1 System Requirements Venting CodesBalanced Flue Construction Public GaragesHazardous Locations Installation Safety EquipmentInstallation Tools Installation MaterialsGeneral Venting Guidelines Required Safe Distances from Combustibles Model Inches Metric cmHang the Heater Remove Shipping Screw from Control Housing DoorNon-residential applications Typical Installation Dimension Model Minimum MaximumHorizontal Installation Heater Orientation13 45 Tilted Installation 45 Tilted InstallationGrille Installation for Select Models Only Silicone Cap InstallationVenting Installation Install Galvanized CollarGeneral Venting Requirements United States RequirementsGalvanized Horizontal Venting Bird Screen Installation Galvanized Horizontal Venting with an ElbowHorizontal Installation Top View Elbow Assembly Vent Assembly Overview Assembly OverviewHorizontal Installation Side View Cox Geelen Venting Cox Geelen Horizontal VentingFlue Collar and Adapter Part Number DescriptionVertical Venting Configurations Cox Geelen Vertical VentingVent Clamp Electrical Service Installation Heater Rating 120V, 60 Hz, Single Phase, 1AThermostat Placement System RequirementsThermostat Installation Rear View GAS Service Installation 7.1 Install Gas Supply Lines Testing Operation 8.1 Operating InstructionsTo Turn Off Gas To Heater Sequence of OperationCover Cap Regulator Screw Outlet Pressure Tap Possible Cause Try this Blower does not Come onIgniter does not Spark LP Gas Burner does not LightNatural Gas Manometer Reading Burner Cycles on and OFF TOO Quickly Housing door. See Page 17, Section Burner Makes Vibrating Noises While RunningMaintenance 10.1 Pre-Season Maintenance Wiring Diagrams 11.1 Connection Diagram Connection DiagramLadder Diagram Ladder Diagram Replacement Parts Illustrated Parts List for Burner Illustrated Parts ListReplacement Parts List for Burner Part Number Description CGTH-30 CGTH-40 CGTH-50 ROBERTS-GORDON will not PAY for Warranty is Void ifLimitations on Authority Representatives Page Owner Warranty Registration Card Page
Related manuals
Manual 30 pages 54.92 Kb

CGTH-40, CGTH-50, CGTH-30 specifications

Roberts Gordon is a renowned manufacturer known for its innovative heating solutions, particularly in the realm of infrared heaters. Among their product lineup, the CGTH series, which includes the CGTH-50, CGTH-40, and CGTH-30 models, exemplifies high-performance technology tailored specifically for industrial and commercial applications.

The CGTH series is designed for versatility and efficiency, offering advanced features that enhance the heating experience in various environments. One of the standout features of these heaters is their infrared technology, which provides targeted warmth, making them ideal for large, open spaces such as warehouses, factories, and sporting facilities. Infrared heaters work by directly heating objects and people in their path rather than the air, ensuring quicker warmth and greater energy efficiency.

Each model offers different heating capacities, with the CGTH-50 boasting a maximum output of 50,000 BTUs, the CGTH-40 providing up to 40,000 BTUs, and the CGTH-30 generating 30,000 BTUs. This variety allows users to choose a model that best fits their heating needs based on the size and requirements of their space.

The units are designed for easy installation, featuring a modular design that allows for both indoor and outdoor applications. Moreover, the heaters can be integrated with various control systems, including programmable thermostats and remote management, enhancing user convenience and optimizing energy usage.

A critical aspect of the CGTH series is its emphasis on durability and safety. Each model is crafted using high-quality materials that can withstand harsh conditions typically found in industrial settings. Additionally, they incorporate safety features such as over-temperature protection and robust mounting brackets, ensuring peace of mind during operation.

Another important characteristic of the CGTH series is their efficiency. By minimizing energy waste and targeting heat output precisely, these heaters can significantly lower energy costs, making them not only environmentally friendly but also economically advantageous for businesses.

In summary, the Roberts Gordon CGTH-50, CGTH-40, and CGTH-30 infrared heaters stand out for their innovative technology, energy efficiency, and reliability. Whether for large commercial spaces or industrial environments, these heating solutions are designed to provide the comfort and performance required for any operation. With their robust features and customizable options, they remain a top choice for effective heating solutions in diverse settings.