Roberts Gorden CGTH-50 Before YOU Begin 1.1 Read This Manual, Questions, Comments or Suggestions

Page 7

SECTION 1: BEFORE YOU BEGIN

SECTION 1: BEFORE YOU BEGIN 1.1 Read This Manual

Read this manual carefully before installing or servic- ing this equipment. Improper installation, servicing or maintenance can result in death, injury or property damage. Check the required safe distances from combustibles given on the outside of each burner to make sure that the product is suitable for your appli- cation. The required safe distances from combusti- bles are also found on Pages 15 and 16 of this manual. Installer must be a contractor qualified in the installation and service of gas-fired heating equip- ment. After the installation is complete, check product operation as provided in these instructions.

1.2 Questions, Comments or Suggestions

Please direct any questions, comments or sugges- tions to:

Roberts-Gordon, LLC

1250 William Street

P.O. Box 44

Buffalo, New York 14240-0044

Telephone: 716.852.4400

Fax: 716.852.0854

Toll Free: 800.828.7450

1

Image 7
Contents Gas-Fired, Low-Intensity Page 2005 Page Table of Figures Page Questions, Comments or Suggestions Before YOU Begin 1.1 Read This ManualRoberts-Gordon, LLC Safety Unpacking the Heater 2.3.1 Manpower RequirementsAbout the Heater Carton Contents of Heaters with Galvanized Venting Manual Gas Shut-off Valve Carton Contents of Heaters with Cox Geelen VentingHeater Assembly Available as an accessory under kit part numbersAvailable Accessories for Galvanized Vent Wall Venting Kit P/N 08032200 includes CGTH-Series by Components Identification Components IdentificationVenting Specifications Heater SpecificationsWhere Cant the Heater Be Installed? Where Can the Heater Be Installed?Planning 3.1 General Gas Service Requirements 3.2.1 Gas TypeMeter and Service Electrical Service RequirementsPublic Garages Venting Requirements 3.4.1 System RequirementsVenting Codes Balanced Flue ConstructionHazardous Locations Installation Materials InstallationSafety Equipment Installation ToolsGeneral Venting Guidelines Required Safe Distances from Combustibles Inches Metric cm ModelHang the Heater Remove Shipping Screw from Control Housing DoorNon-residential applications Heater Orientation Typical InstallationDimension Model Minimum Maximum Horizontal Installation45 Tilted Installation 13 45 Tilted InstallationSilicone Cap Installation Grille Installation for Select Models OnlyUnited States Requirements Venting InstallationInstall Galvanized Collar General Venting RequirementsGalvanized Horizontal Venting Galvanized Horizontal Venting with an Elbow Bird Screen InstallationHorizontal Installation Top View Elbow Assembly Assembly Overview Vent Assembly OverviewCox Geelen Horizontal Venting Horizontal Installation Side View Cox Geelen VentingPart Number Description Flue Collar and AdapterCox Geelen Vertical Venting Vertical Venting ConfigurationsVent Clamp System Requirements Electrical Service InstallationHeater Rating 120V, 60 Hz, Single Phase, 1A Thermostat PlacementThermostat Installation Rear View GAS Service Installation 7.1 Install Gas Supply Lines Sequence of Operation TestingOperation 8.1 Operating Instructions To Turn Off Gas To HeaterCover Cap Regulator Screw Outlet Pressure Tap Possible Cause Try this Blower does not Come onIgniter does not Spark LP Gas Burner does not LightNatural Gas Manometer Reading Burner Cycles on and OFF TOO Quickly Burner Makes Vibrating Noises While Running Housing door. See Page 17, SectionMaintenance 10.1 Pre-Season Maintenance Connection Diagram Wiring Diagrams 11.1 Connection DiagramLadder Diagram Ladder Diagram Illustrated Parts List for Burner Illustrated Parts List Replacement PartsReplacement Parts List for Burner Part Number Description CGTH-30 CGTH-40 CGTH-50 ROBERTS-GORDON will not PAY for Warranty is Void ifLimitations on Authority Representatives Page Owner Warranty Registration Card Page
Related manuals
Manual 30 pages 54.92 Kb

CGTH-40, CGTH-50, CGTH-30 specifications

Roberts Gordon is a renowned manufacturer known for its innovative heating solutions, particularly in the realm of infrared heaters. Among their product lineup, the CGTH series, which includes the CGTH-50, CGTH-40, and CGTH-30 models, exemplifies high-performance technology tailored specifically for industrial and commercial applications.

The CGTH series is designed for versatility and efficiency, offering advanced features that enhance the heating experience in various environments. One of the standout features of these heaters is their infrared technology, which provides targeted warmth, making them ideal for large, open spaces such as warehouses, factories, and sporting facilities. Infrared heaters work by directly heating objects and people in their path rather than the air, ensuring quicker warmth and greater energy efficiency.

Each model offers different heating capacities, with the CGTH-50 boasting a maximum output of 50,000 BTUs, the CGTH-40 providing up to 40,000 BTUs, and the CGTH-30 generating 30,000 BTUs. This variety allows users to choose a model that best fits their heating needs based on the size and requirements of their space.

The units are designed for easy installation, featuring a modular design that allows for both indoor and outdoor applications. Moreover, the heaters can be integrated with various control systems, including programmable thermostats and remote management, enhancing user convenience and optimizing energy usage.

A critical aspect of the CGTH series is its emphasis on durability and safety. Each model is crafted using high-quality materials that can withstand harsh conditions typically found in industrial settings. Additionally, they incorporate safety features such as over-temperature protection and robust mounting brackets, ensuring peace of mind during operation.

Another important characteristic of the CGTH series is their efficiency. By minimizing energy waste and targeting heat output precisely, these heaters can significantly lower energy costs, making them not only environmentally friendly but also economically advantageous for businesses.

In summary, the Roberts Gordon CGTH-50, CGTH-40, and CGTH-30 infrared heaters stand out for their innovative technology, energy efficiency, and reliability. Whether for large commercial spaces or industrial environments, these heating solutions are designed to provide the comfort and performance required for any operation. With their robust features and customizable options, they remain a top choice for effective heating solutions in diverse settings.